PERFORMANCE DATA AND PRESSURE CURVES
5-38
Revision YO5-01
Service Manual - WMZ
5.28.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL (
°
C)
15 20 25
ENTERING AIR
WB OU COIL (
°
C)
TH PI TH PI TH PI
-10
3.66
2.13
3.52
2.27
3.39
2.38
-7
3.94
2.18
3.80
2.30
3.66
2.43
-2
4.19
2.21
4.05
2.34
3.91
2.47
2
5.10
2.31
4.89
2.46
4.68
2.61
6
7.19
2.49
6.98
2.66
6.74
2.82
10
7.82
2.63
7.61
2.81
7.40
3.00
15
8.45
2.74
8.24
2.95
8.03
3.14
20
8.90
2.82
8.69
3.06
8.45
3.30
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.29 Capacity
Correction
Factor Due to Tubing Length
5.29.1 Cooling
TOTAL TUBING LENGTH
3m
7.5m
10m 15m 20m 25m 30m 40m 50m
1.03
1
0.976 0.946 --- --- --- --- ---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
5.29.2 Heating
TOTAL TUBING LENGTH
3m
7.5m
10m 15m 20m 25m 30m 40m 50m
1.06
1
0.979
0.973 --- --- --- --- ---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
Summary of Contents for WMZ Series
Page 19: ...4 2 OUTLINE DIMENSIONS Revision Y05 01 Service Manual WMZ 4 3 GCZ 7 9 12 4 4 GCZ 17...
Page 20: ...4 3 OUTLINE DIMENSIONS Revision Y05 01 Service Manual WMZ 4 5 GCZ 22...
Page 147: ...15 2 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual WMZ...
Page 148: ...15 3 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual WMZ...
Page 149: ...15 4 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual WMZ...
Page 150: ...15 5 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual WMZ...