Electra KIT AUDIO DOOR PHONE basic1 family User Manual Download Page 5

05

Retainer

DIN rail

1

2

3

A3,5 x 32 screw (2 pcs.)

B2,9 x 13 screw (4 pcs.)

Protection lid (2 pcs.)

DIN rail mounting

Wall mounting

EN

4

.

2

  

Safety instructions for installation

è

ATTENTION! The installation, the connection to the 230V/50 Hz network and 

the maintenance of the Supply control unit Supply control unit will only be 

carried out by authorized personnel!

è

The installation of the Supply control unit is recommended to be made within 

an electrical panel.

è

ATTENTION! DO NOT UNFASTEN THE FRONT LID! DANGER OF 

ELECTRIC SHOCK!

         Only the protection lids of the connections can be unfastened.

è

ATTENTION! It is mandatory for the supply of the Supply control unit from 

the 230 V/50Hz network to be made through two automatic fuses of 10 A (on 

phase and null). The connection of the F and N terminals of the Supply control 

unit will be made through two isolated (Cu) wires, with a section of 0,75mm².

è

ATTENTION! During the installation, connection of the Supply control unit at 

the 230 V/50Hz network and during service, the safety fuses from the panel 

must be opened (POWER OFF).

è

The connection of the (Cu) 0,75mm² grounding wire between the grounding 

terminal of the electrical panel        and the grounding terminal of the Supply 

control unit        is MANDATORY.

è

 IMPORTANT! Before connecting the Supply control unit's supply fuses, check 

the precision of the connections in the system. Check both visually, and by 

measurement with an ohmmeter.

è

 IMPORTANT! Install the protection lids of the Supply control unit's 

connections before connecting the 2 supply fuses (230V/50Hz).

è

PAY ATTENTION to the polarity of the terminals when connecting them to 

the Supply control unit of a buffer accumulator (max. 7 Ah). The inversion of 

the terminals leads to the failure of the accumulator. The installation and 

connection of the accumulator will be carried out by authorized personnel.

è

 DO NOT TOUCH the wires exiting from the connectors and the terminals of 

the control supply unit. Disconnect the fuses (10 A) from the supply's phase 

and null of the Supply control unit.

è

 ATTENTION! Do not supply components of the installation separately 

(Outdoor panel, connection boxes, Terminals etc.) at tensions higher than 15V 

DC or directly from the network (230V/50Hz). DANGER OF ELECTRIC 

SHOCK and of the door phone system's destruction.

Summary of Contents for KIT AUDIO DOOR PHONE basic1 family

Page 1: ...m the Outdoor panel s key Full duplex hands free audio communication Command of the access gate door opening from the interior Terminal Audio monitoring of the entrance of the property by the inhabita...

Page 2: ...e outdoor audio panel Supply tension 12 0 14 3 V DC stabilized Display of the inhabitant s name Backlit name space Case Aluminum profile painted in electrostatic field Secured glass screen 8 mm thick...

Page 3: ...e ABS Glass screen 3 mm thick Mounting Surface Casing protection level IP IP31 2 3 Technical features of the Supply control unit Supply tension 230V 10 50Hz 14V GND 14V DC stabilised 2A DC Uv GND 14V...

Page 4: ...CAT5e AWG24 cable for distances of maximum 70 m between the Outdoor panel and the Supply control unit and 250m between the Outdoor panel and the audio Terminal For distances greater than 250 m please...

Page 5: ...must be opened POWER OFF The connection of the Cu 0 75mm grounding wire between the grounding terminal of the electrical panel and the grounding terminal of the Supply control unit is MANDATORY IMPORT...

Page 6: ...eight recommended height 4 4 Installation of the audio terminal 1 2 A3 5 35 32 screw 4 pcs 18 cm Cable length from the wall 96 5 171 5 29 5 21 48 2 20 5 113 5 37 5 95 7 60 0 155 cm 06 The accumulator...

Page 7: ...ance door Customization of the name display Remove the plastic pad from the keyboard module Insert the pad back in the keyboard module Affix a sticker with the name cut to size on the white space allo...

Page 8: ...lectromagnetic lock Optional Optional Optional 5 1 Installation of the electromagnetic lock optional Direct current DC Direct current electromagnetic lock DC LC2 Cable 2 x 0 75 mm BUT LC LA C LA Suppl...

Page 9: ...eck the existence of the supply tensions with the values mentioned below at the terminals of the Supply control unit use a direct current voltmeter Tensions measured at the terminals of the Supply con...

Page 10: ...han 12 0V Check the functions of the Terminals and of the Outdoor panel call communication access audio monitoring The system is adjusted by the producer in what concerns the audio part for standard f...

Page 11: ...nctions supply control unit with accumulator 7 Short circuit between the CD and GND or 14V connections 11 EN The system functions Supply control unit with accumulator Control unit S1 red intermittent...

Page 12: ...ite LED and turned off red LED The red LED will remain permanentlyturned on until the keyis pressed again 2 CALL AND COMMUNICATION Call duration maximum 15 s 3calls Communication duration maximum 2 mi...

Page 13: ...bitant s name are permanently backlit 2 CALL AND COMMUNICATION Call duration maximum 15 s 3 calls Communication duration maximum 2 min Touch the key The call to the inhabitant is signaled acoustically...

Reviews: