CONTROL
SYSTEM
11-2
SM JGF 1-A.1 GB
11.1.2
System Operation Concept
11.1.3 Compressor
operation
For each Mode including POWER OFF & SB, a Min time delay of 3 min before COMP restarting
except during outdoor deicing.
Whenever COMP starts, it will not stop in 6 min even the RAT is changed.
* For the units with memory function, the 1
st
time of Power ON, there will be no 3 min delay if the
previous stage of unit is OFF.
11.1.4
Indoor Fan Control
8 Indoor fan speeds are determined for each model. 4 speeds for COOL modes and 4 speeds for
HEAT mode.
Unit Model
Mode
Turbo(Super high)
High
Medium
Low
Cooling 1390
1280 1180 1080
09
Heating 1350
1250 1140 1040
Cooling 1350
1250 1100 950
12
Heating 1350
1250 1100 950
Cooling 1350
1200 1050 900
18
Heating 1350
1200 1050 900
Cooling 1350
1200 1050 900
24
Heating 1420
1250 1150 900
In high/ medium/ low indoor fan user setting, unit will operate fan in selected speed.
In AutoFan user setting, fan speed will be adjusted automatically according to the difference
between actual room temperature(RAT) and user set point temperature(SPT).
Indoor Fan speed
High
Medium
Low
Cooling
>=2
(0,2)
<=0
RAT-SPT
Heating <=1
(1,3)
>=3
During Auto Fan operating, one speed should keep at least 210sec operating before switching to
other speeds.
In DRY mode, the automatic fan speed is forced to be low.
11.1.4.1 Turbo Speed
In COOL and HEAT mode (not available in AUTO, DRY, FAN mode), press the Turbo button, the
super high fan speed is selected on Remote control and the indoor fan rotates at super high speed.
11.1.5
Outdoor Fan Control
Summary of Contents for ELAU-VGF009-H11
Page 14: ...OUTLINE DIMENSION 4 2 SM JGF 1 A 1 GB 4 2 Outdoor VGF009 012 018 024 Model 09 12 Model 18 24...
Page 33: ...WIRING DIAGRAM SM JGF 1 A 1 GB 8 1 8 WIRING DIAGRAM 8 1 JGF009 VGF009...
Page 34: ...WIRING DIAGRAM 8 2 SM JGF 1 A 1 GB 8 2 JGF012 VGF012...
Page 35: ...WIRING DIAGRAM SM JGF 1 A 1 GB 8 3 8 3 JGF018 VGF018...
Page 36: ...WIRING DIAGRAM 8 4 SM JGF 1 A 1 GB 8 4 JGF024 VGF024...
Page 37: ...REFRIGERATION DIAGRAMS SM JGF 1 A 1 GB 9 1 9 REFRIGERATION DIAGRAMS...
Page 51: ...EXPLODED VIEW SPARE PART LIST SM JGF 1 A 1 GB 13 3 13 3 Exploded view of indoor unit JGF012...
Page 53: ...EXPLODED VIEW SPARE PART LIST SM JGF 1 A 1 GB 13 5 13 5 Exploded view of indoor unit JGF018...
Page 55: ...EXPLODED VIEW SPARE PART LIST SM JGF 1 A 1 GB 13 7 13 7 Exploded view of indoor unit JGF024...
Page 57: ...EXPLODED VIEW SPARE PART LIST SM JGF 1 A 1 GB 13 9 Exploded view of outdoor unit VGF009 VGF012...
Page 60: ...EXPLODED VIEW SPARE PART LIST 13 12 SM JGF 1 A 1 GB 13 11 Exploded view of outdoor unit VGF018...
Page 62: ...EXPLODED VIEW SPARE PART LIST 13 14 SM JGF 1 A 1 GB 13 13 Exploded view of outdoor unit VGF024...
Page 64: ......
Page 65: ...APPENDIX SM JGF 1 A 1 GB 14 1 14 APPEDDIX APPENDIX...