6
SENSOR SENSOR
LESS SENSITIVE MORE SENSITIVE
FIGURE 2
INSTALLATION
A drill and a screwdriver are needed for installation.
Select a location for the unit to have the best detection
coverage, the device provides up to 12 meter distance
in the center line and maximum to 180
˚
angle at
recommended 1.8 meter height as shown in FIGURE
3.
FIGURE 3
Install a wall switch adjacent to the power source.
(FIGURE 4) This helps
you operate AUTOMATIC
OPERATION and MANUAL OVERRIDE with ease.
See OPERATION section for more information.
FIGURE 4
WIRING INSTRUCTION
(7) Switch off the AC mains power or circuit breaker.
(8) Unscrew the bottom housing, using a flat blade
screwdriver to detach the base cover from the
unit. (FIGURE 5)
FIGURE 5
(9) Strip approximately 6-8mm insulating part of the
wires from the power cord. Before connection,
run the wires through the rubber seal provided.
(10) For power wire connection, connect the BROWN
wire (Live wire) to the terminal block “L” mark.
Connect the BLUE wire (Neutral wire) to the
terminal block “N” mark,
For lamp wire connection, connect the BLUE wire
to the terminal block “N” mark, connect the
BROWN wire to the terminal block “LS” mark.
(FIGURE 6).
FIGURE 6
(11) For wall mount, make use of the base cover as a
template to mark the position of two screw holes
on the wall. Drill the wall and screw the base
cover onto the wall using suitable plastic wall
plugs and screws provided (FIGURE 7), screw up
the bottom to fix the unit (FIGURE 8).