2
SPECIFICATIONS & OPERATING RANGE
DUCTED SPLIT A.C
PG. 2-
12
SERIES: LS
REV. 01 12/2002
NOTES:
1. Rating conditions ISO/CD 13253R
Cooling: indoor: 27
°
C (80
°
F) DB 19
°
C (66
°
F) WB
Outdoor: 35
°
C (95
°
F) DB
Heating: indoor: 20
°
C (68
°
F) DB
Outdoor: 7
°
C (45
°
F) DB 6
°
C (43
°
F) WB
Refrigerant tubing length (one way) 7.5m (24.6 ft)
2. Guaranteed operating range:
Indoor
Outdoor
Upper limit
32
°
C DB, 23
°
C WB
46
°
C DB
Cooling
Lower limit
21
°
C DB, 15
°
C WB
21
°
C DB
Upper limit
27
°
C DB
24
°
C DB, 18
°
C WB
Heating
Lower limit
20
°
C DB
-9
°
C DB, -10
°
C WB
1 PH
198 – 242 V
Voltage
3 PH
360 – 440 V
Rev.: A
Series: IOD/CON
Date: 12/01/2004
ELECTRA CONSUMER PRODUCTS LTD