Connection of additional panels
5
To one or
more families
C/D
GND
Vout
+
14
C/D
GND
Vout
+
14
VPA1 (
ad
dress 1)
110Va.c.
230Va.c.
+
14
C/D
GND
Vin
VPA2 (
ad
dress 2)
+
14
C/D
GND
Vin
+
14
C/D
GND
Vin
+
14
C/D
GND
Vin
110Va.c.
230Va.c.
110Va.c.
230Va.c.
110Va.c.
230Va.c.
C/D
GND
Vout
+
14
C/D
GND
Vin
+
14
C/D
GND
Vout
+
14
C/D
GND
Vout
+
14
VSB
1
2
3
4
C/D
GND
Vout
+
14
C/D
GND
Vout
+
14
C/D
GND
Vout
+
14
C/D
GND
Vout
+
14
VPA3 (
ad
dress 3)
VPA4 (
ad
dress 4)
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
Important:
One
VPA
video panel and one
SCU
central unit will be mounted at each entrance.
The programming of the addresses for the panels connected in parallel is done as follows:
a.
The
VPA1
panel keeps
address 1
, which is set from the factory.
b.
The
VPA2
panel with
address 2
:
Step 1
Long press the
PROG
button at
SCU2
The red LED turns on.
Step 2
Long touch the
Fam.1
key at the
VPA2
panel
Long beep.
Step 3
Short touch the
Fam.1
key, twice
Two short beeps
confirmation.
Step 4
Short touch the
PROG
button at
SCU2
to exit programming mode
The red LED turns off.
c.
The
VPA3
panel with
address 3
:
Step 1
Long press the
PROG
button at
SCU3
The red LED turns on.
Step 2
Long touch the
Fam.1
key at the
VPA3
panel
Long beep.
Step 3
Short touch the
Fam.1
key, three times
Three short beeps
confirmation.
Step 4
Short touch the
PROG
button at
SCU3
to exit programming mode
The red LED turns off.
d.
The
VPA4
panel with
address 4
:
Step 1
Long press the
PROG
button at
SCU4
The red LED turns on.
Step 2
Long touch the
Fam.1
key at the
VPA4
panel
Long beep.
Step 3
Short touch the
Fam.1
key, four times
Four short beeps
confirmation.
Step 4
Short touch the
PROG
button at
SCU4
to exit programming mode
The red LED turns off.
SCU1
SCU2
SCU3
SCU4
EN