background image

 

• If the hood is being installed so that the air is vented outside, there MUST 

be adequate ventilation of the room when the hood is used at the same 
time as appliances burning gas or other fuels  – use of the hood may be 
dangerous as it could draw back the fumes from the other appliances which 
would  otherwise  be  vented  outside.  If  adequate  ventilation  can  only  be 
ensured  via  an  open  window,  a  window  contact  switch  should  be  fitted, 
(available  from  good  DIY  stores  or  Builders  merchants)  which  will  then 
ensure  the  hood  may  only  be  operated  when  the  window  is  sufficiently 
opened. Please note – the above does NOT apply if the hood is only used 
in recirculation mode with charcoal filters. 

• Regulations concerning the discharge of air have to be fulfilled. 
• If used in recirculation mode, the charcoal filters trap odours and must be 

replaced at least once a year depending on how frequently the cooker hood 
has been used. 

• The  installation  instructions  for  range  hoods  with  accessible  metallic 

enclosures  of  class  II  construction  shall  include  details  that  indicate  the 
location and maximum permitted lengths for any fixing or mounting screw 
or  other  fixing  device  that  penetrates  into  the  range  hood  to  attach  an 
accessory such as a facia or duct fitting. 

• Where  fixing  or  mounting  screws,  or  other  fixing  devices  are  used,  that 

penetrate into the range hood with an accessible metallic enclosure of class 
II construction, to  attach an accessory,  the instructions shall indicate  the 
required  location  of  these  screws  or  fixing  devices  and  include  the 
substance of the following warning. 

• For  safety  reason,  please  use  only  the  same  size  of  fixing  or  mounting 

screw which are recommended in this instruction manual. 

• Warning: Failure to install the screws or fixing device in accordance with 

these instructions may result in electrical hazards 

• Regarding the instructions for the bulb changing, refer to the section “bulb 

changing”. ILCOS D code for this lamp is: DBR-2/65-H. 

 

CAUTION: Accessible parts of the hood can become very hot during 

use with cooking appliances, whether in use or not, due to heat rising 
from  the  hob.  Sufficient  cooling  time  should  be  allowed  before 
touching either the housing or the grease filter(s)

 

 

 

 

 

Summary of Contents for eiQ90CANOPYSTEEL

Page 1: ...AL CANOPY COOKER HOOD eiQ90CANOPYSTEEL Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference Visit our page www electriQ co uk fo...

Page 2: ...S SAFETY 3 UNPACKING AND PRODUCT OVERVIEW 5 OPTIONS FOR VENTILATION 6 INSTALLATION 7 OPERATION 8 FILTER REPLACEMENT 9 BULB REPLACEMENT 10 MAINTENANCE 11 TROUBLESHOOTING 12 TECHNICAL SPECIFICATION 13 S...

Page 3: ...not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room Do not leave fry...

Page 4: ...lass II construction shall include details that indicate the location and maximum permitted lengths for any fixing or mounting screw or other fixing device that penetrates into the range hood to attac...

Page 5: ...marked by careless unpacking are not covered under the guarantee Carefully unpack the contents and check everything is there using the table in the next section Product overview parts supplied Packagi...

Page 6: ...should be made The unit is also provided with an adaptor allowing pre existing 120mm ducting to be used to vent the unit RECIRCULATION This Cooker hood also supports the recirculation of the air once...

Page 7: ...ood Unit itself where the air outlet vent is located the 2 x flaps should be carefully installed bending very slightly so the lugs at each end locate into the holes enabling flaps to pivot upwards whe...

Page 8: ...he hood and connect the opposite end of the vent pipe if required OPERATION Your cooker hood is provided with two easy to use slide switches There are 3 speeds for the motor and a separate switch for...

Page 9: ...uld first be detached Press the lock and pull it downward Put the activated carbon filters into the unit fix them by turning them clockwise onto both sides of the motor housing NOTE Make sure the filt...

Page 10: ...y 2 Remove the aluminum grease filter 3 Unscrew the panel from the main unit using the 4 screws 4 Follow the wire from the light fitting and disconnect it at the connector with the hood 5 Remove the l...

Page 11: ...urate the filter Remove the filter as shown in the Installation section Clean it with a soft nylon brush in a mild solution of warm water and a small amount of washing up liquid Washing up liquid alon...

Page 12: ...carried out by qualified service personnel only The fan motor is not fixed tightly Switch off the unit Repair to be carried out by qualified service personnel only The unit is not hung properly on th...

Page 13: ...int WBEP 133 1 W Nominal power of the lighting system WL 4 2 W Average illumination of the lighting system on the cooking surface Emiddle 137 lux Measured power consumption on standby mode PS W Measur...

Page 14: ...AM 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Low elds Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit...

Reviews: