QUANTUM CLASSIC 

Photocatalytic Pool Sanitiser 

Installation & Operating Manual 

Q-65   Q-130

 

 

                                    

 

                 

                            

 

 
 

 

 

Summary of Contents for QUANTUM CLASSIC Q-65

Page 1: ...QUANTUM CLASSIC Photocatalytic Pool Sanitiser Installation Operating Manual Q 65 Q 130...

Page 2: ...on 6 3 4 Connection 8 3 6 Electrical connection 9 4 OPERATING INSTRUCTIONS 9 4 1 Flow requirements 9 4 2 Lamp life indicator 9 4 3 Water quality 10 5 MAINTENANCE 10 5 1 Essential parts to carry out an...

Page 3: ...must be earthed Power must be supplied through a Residual Current Device RCD with a rated residual operating current not exceeding 30mA Do not run this unit dry Do not cover this unit The unit must no...

Page 4: ...ilable in 55W single tube and 110W double tube formats supplied complete with flow switch and either an analogue lamp life indicator and reset switch or digital lamp life countdown with intelligent do...

Page 5: ...lling vertically the 1m clearance space must be above or below the unit if installing horizontally the 1m clearance space must be to the left or right of the unit WARNING The Quantum must be installed...

Page 6: ...4 Fig 5 3 3 Flow direction The Quantum is factory set to accept input water flow entering on the left and exiting on the right this can be reversed by rotating the flow switch 180 degrees i e turn see...

Page 7: ...rsing the flow direction if it is lifted by more than 5mm from its housing and turned with force If the flow switch has been rotated it is important to ensure that it is finally locked in the correct...

Page 8: ...7 All factory unions are made from ABS plastic when gluing connections to an ABS pipe an ABS cement must be used or when using a PVC pipe a Transition cement must be used See Fig 7 There is no need t...

Page 9: ...hour 14 000 litres per hour 110W double tube 28m3 hour 28 000 litres per hour A higher flow rate will require the installation of a bypass to prevent damage to the unit This unit is a plug and play de...

Page 10: ...and optimum performance annual maintenance of the UV steriliser is essential Failure to do so could result in damage to the product and significant drop in efficiency Annual maintenance includes Chan...

Page 11: ...lip in shown direction to unlock from body 2 Pull the second side after unlocking the 1st side Remove Lamp holder Clip from Hard cap Unmount the Hard cap from Blue lamp Holder Carefully remove the blu...

Page 12: ...cale will limit the effectiveness of the UV lamp s Assembly process Firstly slide the clean dry quartz glass sleeve into the unit Locate the O rings carefully on the ends of the quartz sleeve Make sur...

Page 13: ...t for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health...

Page 14: ...14 Notes...

Page 15: ...ertfordshire SG1 2BH United Kingdom __________________________________________________________________________________ Customer Information ATTACH TO THE PRODUCT Company Name Contact Name Daytime Tele...

Page 16: ...16 Unit 11 Gunnels Wood Park Stevenage Herts SG1 2BH Sales elecro co uk www elecro co uk 44 0 1438 749474 Copyright MANE166 EN Quantum Classic Manual V2 31 08 2021 Elecro...