background image

2.5 Power requirements 

 

220

– 240V 1-Phase Power Output

 

Load

 

1-kW 

5-Amp 

2-kW 

9-Amp 

3-kW 

13-Amp 

4-kW 

18-Amp 

4.5-kW 

20-Amp 

5-kW 

22-Amp 

6-kW 

27-Amp 

 

400V 3-Phase Phase Power Output

 

Load

 

8-kW 

20-Amp 

 

3.  OPERATING INSTRUCTIONS 

 

3.1 Flow requirements 

 

The flow rate of water into the heater must not exceed 17,000 litres per hour (17m

3

/hour/3,740 UK gallons 

per  hour).  A  higher  flow  rate  will  require  the  installation  of  a  by-pass  to  prevent  damage  to  the  heater 
elements. 
  

NOTE: The heater will not operate unless the following minimum flow rates are achieved: 

1,000 litres/hour (1m

3

/hour / 220 UK gallons/hour). 

 

3.2 Water quality 

 

The water quality 

MUST

 be within the following limits: 

 

  PH: 6.8 

– 8.0 

  Total Alkalinity (TA): 80 

– 140 ppm (parts per million) 

  Chloride Content MAX: 150 mg/litre 

  Free Chlorine: 2.0 mg/litre 

  Total Bromine: Max 4.5 mg/litre 

  Total Dissolved Solids (TDS)/Calcium hardness: 200 

– 1,000 ppm 

 

The permitted salt concentration is dependent on the model of heater purchased:  
 

  Incoloy 825 heating element = Zero salt content permitted 

  Titanium heating element = MAX salt content of 8,000ppm (8g/litre)  

  For salt concentrations greater than 8,000ppm a Titanium flow tube and Titanium heating element 

model 

mus

t be installed.  

 

Upon completion of the installation, run the water-circulating pump to purge the system and heater of air 
(i.e. remove any trapped air in the system and heater). 
 

  Switch on the power supply to the heater. This will be indicated by the illuminated Amber light on 

the panel. 

  Turn the thermostat to the desired temperature. 

  The heater will only start heating (red light indicator illuminated) when the following criteria are met: 

 

Water circulating pump is ‘On’ delivering more than the minimum flow rate of water (see 3.1 
flow requirements). 

  The required water temperature point is set to a higher value than that of the water. 

 
 
 

Summary of Contents for Nano SPA Heater

Page 1: ...Nano SPA Heater Installation Operating Manual...

Page 2: ...ion 4 2 2 Pipework 4 2 3 Flow direction 6 2 4 Electrical connection 6 2 5 Power requirements 7 3 OPERATING INSTRUCTIONS 7 3 1 Flow requirements 7 3 2 Water quality 7 4 TROUBLESHOOTING 8 5 MAINTENANCE...

Page 3: ...of trouble free service please read and follow these instructions for proper installation maintenance and use Incorrect installation will affect the warranty WARNING Failure to install the unit correc...

Page 4: ...of the heater The unit must not be covered to allow adequate ventilation The heater must be installed within a dry permanent weather proof area In any case where water or moisture enters the enclosur...

Page 5: ...letely full of water during operation the return pipe which carries the water back to the pool must incorporate a safety loop or kick up in the pipe as close as possible to the heater see Fig 3 NOTE W...

Page 6: ...ecause of the ridges in the pipe it will not squeeze down tight It will need to be sealed with a bathroom type mastic sealant 2 3 Flow direction The heater can accept the flow of water from only one e...

Page 7: ...ax 4 5 mg litre Total Dissolved Solids TDS Calcium hardness 200 1 000 ppm The permitted salt concentration is dependent on the model of heater purchased Incoloy 825 heating element Zero salt content p...

Page 8: ...the test i e with the heater red light On To avoid inaccurate results when performing this test it is important to refrain from using other high current consuming appliances in the property such as tu...

Page 9: ...ble Check both ends of the power supply cable at the distribution box and at the heater terminal block Remedy Contact an Electrician to check installation and protection Heater is tripping circuit bre...

Page 10: ...ocess 5 MAINTENANCE We recommend annual maintenance and cleaning of the heater to ensure proper operation WARNING Before performing any maintenance on the unit isolate from the main power supply The h...

Page 11: ...Proof of purchase may be required The manufacturer will not be liable in cases of incorrect installation of the heater inappropriate use or neglect of the heater Any damages occurred due to shipping m...

Page 12: ...12 8 WIRING DIAGRAMS Nano SPA 1 2 and 3 kW Nano SPA 4 5 and 6 kW Nano SPA 8 kW...

Page 13: ...Hertfordshire SG1 2BH United Kingdom __________________________________________________________________________________ Customer Information ATTACH TO HEATER Company Name Contact Name Daytime Telepho...

Page 14: ...14...

Page 15: ...15 Notes...

Page 16: ...11 Gunnels Wood Park Stevenage Herts SG1 2BH Sales elecro co uk www elecro co uk 44 0 1438 749474 Copyright V01 2019...

Reviews: