11
3.5 Set point
The setting can be changed (desired water temperature), any time by simply turning the knob clockwise
or anti clockwise until the required temperature is shown on the display (see Fig.13). To confirm the
changes, press the knob button (OK).
The display should show ‘SAVED’ message.
Fig. 13
3.6 Heating mode
If the heater is receiving enough flow and the set point value is greater than the pool water temperature
‘HEATER DELAY’ will be shown on the display (see Fig. 14).
It will appear for two minutes before the device commences the heating process. The delay time is required
to prevent a cycling effect due to air pockets trapped in the pipe work system or any water fluctuations.
The combination of the delay time and flow switch sensor is ensuring that the device always receives
enough flow and the heating element is fully submerged. This will extend the life expectancy of the
components and the product.
After two minutes, the controller will switch on the heating output, RED LIGHT will come ON and the display
will show current water temperature (see Fig. 15).
Fig. 14
Fig. 15