29
Tech Mode
Display Panel Text
Display Format,
Two Lines
Definition
ENABLED
AT U I N 1 . 2 : 1
1 6 0 n H 6 1 p F T X
ATU Status
L and C
Combinations
ATU IN:
ATU is active and the SWR after
match is displayed.
Inductance is 160 nH.
Capacitance is 61 pF.
The capacitors are on the TX (source)
side of the inductor.
When the ATU is in BYP, the capacitor
and inductor banks are disconnected.
Menu Items
Tap
M E N U
to toggle between
STATUS
and
MENU
displays to select
MENU
. The Menu function allows the
various parameters to be set. With the menu function enabled, tap the and switches to scroll through the
menu items. Tap and hold either key to scroll quickly. The menu items are in alphabetical order.
To change a parameter, press and hold
E D I T
and the parameter on the LCD will blink. Then tap the and
switches to change the parameter. Tap
M E N U
again to save the parameter and return the and switches for
menu selection.
Tapping
S TAT U S
also exits the menu.
Menu Item Notes
•
Some menu items are “per band”; these menu items show the frequency band along with the parameter
on the LCD. Changing a band parameter changes it only for the band being displayed.
If you wish to change a parameter for more than one band, tap the
BAND
switch while editing the menu
item to view and change the configuration for each band.
•
You may use the
KPA1500 Utility
program to modify several settings on multiple bands.
•
Some menu items, such as serial number and firmware revision, may not be edited.
•
Some menu items appear only when
TECH MODE
is enabled.