7.

 

Installation, Operation, or Illustration 

1.

 

Install the battery (see figure 1) 
 

 

 

 
 
 

 
 

Figure 1 

2. When using the thermometer for the first time or after putting the 
battery in, please wait for 10 minutes before taking measurements. 

3. Select the body temperature mode and keep the thermometer probe 
about 3-5cm away from the forehead, hold the measurement button, slide 
to temple and release the button, the beep is heard, you can now read the 
value. And make sure your forehead is not covered with hair, sweat, 
cosmetic or hat (see figure 2).   

4. Please measure the temperature behind the earlobe if the measured 
forehead temperature is affected by ambient temperature variation or 
sweat. And make sure your earlobe is not covered with hair, sweat, 
cosmetic or hat. 
 

 

 

 

 

 

 

Figure 2 

5. Please select object temperature mode to measure milk, room or other 
object temperature. 
 

Summary of Contents for CCIR1001

Page 1: ...Infrared Thermometer CCIR1001 Instructions Users must read the instructions carefully before using this product Version V1 0 ...

Page 2: ...ng this product and keep the instructions and the thermometer in a safe place The product name Infrared thermometer Model CCIR1001 Application Body temperature Object temperature Package Contents No Name Quantity 1 Infrared thermometer 1 2 Battery AAA optional 2 3 User Manual 1 Registrant Manufacturer Guangdong Chico Electronic Inc Registered Production address Floor 2 Building 7 Hantian science a...

Page 3: ...Installation Operation or Illustration 3 8 Setting description 4 9 How to use thermometer 5 10 Warning and Precautions 5 11 Important note 6 12 Advice before first use 6 13 Care and Cleaning 7 14 Error and Troubleshooting 7 15 Storage requirements 8 16 Symbols 8 17 Safety classification description 8 18 Warranty and After sale Service 9 ...

Page 4: ...the body or object to convert into voltage signal After being amplified by operational amplifier the energy is filtered and put into the analog to digital converter The digital signal is converted into a temperature reading by the central processing unit CPU to show on the LCD display 1 Temperature valve 2 Body mode 3 Object mode 4 Memory Mode No 5 Memory recall 6 Bluetooth reserved 7 Celsius degr...

Page 5: ... 38 0 42 9 red Body temperature mode smiley face crying face 32 1 37 4 display smiley face 37 5 42 9 display crying face 32 1 42 9 display crying face Automatic shutdown 60s 2s 5 Features Non contact accurate and reliable 99 sets of memories easy to recall Auto shut down and power saving Switching between and Mode selection body mode and object mode Backlight with three different color green yello...

Page 6: ... the forehead hold the measurement button slide to temple and release the button the beep is heard you can now read the value And make sure your forehead is not covered with hair sweat cosmetic or hat see figure 2 4 Please measure the temperature behind the earlobe if the measured forehead temperature is affected by ambient temperature variation or sweat And make sure your earlobe is not covered w...

Page 7: ... and value to check ambient temp compensation In this state press MODE button into ambient temp compensation setting then press or to set compensation value when it is complete press SET button to confirm it 5 F1 Body temperature compensation Press button once again in F0 mode till display shows F1 and value to check body temp compensation In this state press SET button into body temp compensation...

Page 8: ...surements can be affected by the hair sweat hat or scarf 6 Please put the thermometer in indoors for at least 30 minutes prior to the measurement when the room temperature changes greatly 7 Keep the thermometer away from direct exposure to the sun and keep it in a dust free dry area well ventilated place at a temperature between 20 55 8 Keep the thermometer away from electrified objects to avoid e...

Page 9: ...riate temperature when taking a temperature 3 Use of this thermometer is not intended as a substitute for consultation with your physician or pediatrician 4 If damaged do not attempt to repair the instrument Please contact dealer 5 Medical electronic products require special precautions according to the EMC regulations 6 The thermometer is suitable for all ages 12 Advice before first use In order ...

Page 10: ... 3 10 years old 36 1 37 8 97 0 100 11 65 years old 35 9 37 6 96 6 99 7 65 years old 35 8 37 5 96 4 99 5 13 Care and Cleaning The measuring probe is the high quality precision part and must be carefully protected Do not touch or press the probe with fingers or other objects Use an alcohol swab or cotton swab moistened with 95 to clean the measuring probe Do not use corrosive cleaning agent Please u...

Page 11: ...the measurement distance is within 3 5cm Display Err The ambient temperature is too high or too low Please keep the thermometer in the new measurement environment for at least 30 minutes The battery icon flashing The battery level is too low Replace two new AAA batteries 15 Storage requirements keep the thermometer in a non corrosive gas dry area well ventilated place at a relative humidity less t...

Page 12: ...input signals and output signals j Input power of equipment inapplicable k Non permanent equipment l EMC GB4824 Group 1 of Class B 18 Warranty and After sale Service The device is under warranty for 1 year from the date of purchase The batteries the packaging and any damage caused by improper use are not covered by the warranty Excluding the following user caused failures 1 Failure resulting from ...

Page 13: ... 10 www elechico com Guangdong Chico Electronic Inc Warranty Card Product Name Product Model Purchase Date Customer Name Customer Com Customer Tel Customer Add Post Codes Signature Seal ...

Page 14: ... 11 www elechico com Guangdong Chico Electronic Inc CERTIFICATION Product Name Product Model Checker Test Date ...

Page 15: ...utomated AOI machine SMT machine automated assembly machine FCT machine and so on In addition we have obtained ISO 9001certificates Selling well in all cities and provinces around China our products are also exported to clients in such countries and regions as United Kingdom France America Middle East and so on Our factory covers an area of about 7000 square meters and possesses a team of hight te...

Page 16: ......