Installing your thermostat
6. System function settings
With power off, press and hold both and for 5
seconds to enter the System Functions. Press to
scroll through the available functions, and use the
and arrows to change the available options.
Your thermostat will automatically exit the System
Functions settings after approximately 15 - 20
seconds of inactivity. All settings are automatically
Wiring your thermostat
Wiring your thermostat
Please note:
1.“Err” on your thermostat indicates a fault without the external (floor) sensor.
Your thermostat will be inoperative until the error is rectified.
2. When sensor selection is “AL” (option 3 above) the room temperature will
be displayed on your thermostat by default. The floor temperature can be
displayed temporarily by pressing the button for three seconds. Your
thermostat will revert to display the room temperature after several seconds.
Your thermostat is suitable for installation within
a standard 86mm pattress box or European 60mm
round pattress box.
will show in the screen.
Touch the icon for four times until the weekday
schedule settings appear (1 2 3 4 5 will show
along the top of the screen).
Use the and arrows to adjust the time for
the 1st (Comfort) period
Press the icon and use the and arrows
to set the temperature for the 1st period.
Repeat this process for periods 2 – 6.
Press the icon once more to enter the
weekend schedule settings (6 & 7 will show along
the top of the screen).
Repeat the above process to set the weekend
schedule. Press once more to confirm and exit.
Default settings for program schedule
Time display
WEEKDAY (MON. – FRI.)
WEEKEND (SAT. – SUN.)
TIME
TEMP.
TIME
TEMP.
Period 1 (Comfort)
06.00 waken
20°C
06.00 waken
20°C
Period 2 (Economy)
08.00 leave
15°C
08.00 leave
20°C
Period 3 (Comfort)
11.30 home
15°C
11.30 home
20°C
Period 4 (Economy)
13.30 leave
15°C
13.30 leave
20°C
Period 5 (Comfort)
17.00 home
22°C
17.00 home
°C
Period 6 (Economy)
22.00 bed
15°C
22.00 bed
15°C
15
Default settings above assume a 5+2 (day) weekly
program.
Please note:
Do not over-tighten the terminals in your thermostat
as damage may occur.
Code
Function
Setting & options
Default
1
Air temperature
calibration
Range is -9°C to +9°C for internal sensor
-2
2
1
3
Button locking
0: = All buttons will lock except the Power button
1: = All buttons will lock
1
4
Sensor selection
In = control temperature using the internal sensor
Ou = control temperature using the external (floor) sensor
Al = control temperature using internal sensor to
control
temperature, and external sensor to
limit
the floor temperature
Remark: Please make sure the right sensor. If choose the
wrong or bad one, LCD will display Err.
In for GA/GC
Al for GB
5
Minimum
temperature setting
Range is 5°C - 15°C.
5
6
Maximum
temperature setting
Range is 15°C - 45°C.
35
7
12/24 hour clock
0: 12h: = 12 Hour clock
1: 24h: = 24 hour clock
1
8
Display Mode
0
:
display both set temp. and room temp.
1
:
display set temp. only
0
9
45
15
AC95~230V
IP20
N
L
1
2
3
4
M
Close
Open
5
6
NTC
WH
L1
N1
LOAD
IP20
N
L
1
2
3
4
NTC
5
6
UH
AC95~230V
WH for water heating, UH for electric heating,
GC for water/gas boiler. External Sensor is optional.
Step 1. Keep power off. See Fig 1.
Fig 1
Step 2. Remove the mounting Plate. See Fig 2.
Fig 2
Step 3. Connect power supply, load and external (floor) sensor
into the appropriate terminals if there is external sensor.
(see “Wiring your thermostat” for details and Fig 3).
Fig 3
Step 4. Fix the mounting plate into the wall with screws in
the box. See Fig 4
Fig 4
Step 5. Fasten body of thermostat and the mounting plate
through the groove. See Fig 5.
Fig 5
Step 6. Installation complete. See Fig 6.
Fig 6
RISK OF ELECTRICAL SHOCK.
Disconnect/isolate
power supply prior to making electrical connections.
Contact with high voltage components can cause electrical
shock, severe injury or death.
AC95~230V
IP20
N
L
1
2
3
4
5
6
NTC
GC
Dry Contact
︽ ︾
︽
︾
0
︽
︾
High temperature
protection setting.
25-70
℃
Deadzone
temperature
1-5
℃
︾