background image

USER MANUAL - EN 

Summary of Contents for C5

Page 1: ...USER MANUAL EN ...

Page 2: ...Disclaimer This user manual is for information only The manufacturer reserves the right to modify any specifications 2 ...

Page 3: ...Table of Contents General Information General Precautions Restrictions Main Features Specifications Regulatory Standards Remote Control FCC IC CE ARIB Battery Charger Lifting Procedure Working Angles Conformity Declaration Manufacturer s Certificate Warranty Inspection Maintenance 4 4 5 6 7 7 8 9 10 10 11 13 17 18 18 EN ...

Page 4: ...service in case of doubts and or questions The automatic lifting clamps have specifically been designed for the horizontal lifting and transpor ting moving of non bending steel plates pipes and H I beams The automatic lifting clamps must always be used in pairs or multiples thereof The Working Load Limit of 5 000 kg 11 023 lb indicated is per lifting clamp refer to sections 11 12 of the user manua...

Page 5: ...sories are of the correct size and suitably fastened to the lifting clamps 15 DO NOT operate the lifting clamps with twisted tangled damaged or worn load slings chain slings or other means and or lifting accessories 16 DO NOT lift the load on the tip of the lifting clamp 17 DO NOT operate the lifting clamps if they do not meet the lifting procedure and or working angles specified in sections 11 12...

Page 6: ...r chains or slings and a hand grip that can also be used as a second lifting point For the lifting of steel plates the tip should be flat For the lifting of pipes the tip should be round For the lifting of beams tip should be H I tip The tip of the automatic lifting clamp can be customized upon customer demand The tip of the lifting clamp must be replaced if to be used as a Pipe Lifting Clamp a Be...

Page 7: ...EN 1050 UNE EN 13155 2004 A2 UNE EN 60204 1 2007 UNE EN 61000 6 4 2007 UNE EN 61000 6 2 2006 UNE EN ISO12100 2012 EN 10204 3 1 B D89 391 EEC D89 654 EEC D89 655 EEC D89 656 EEC D92 58 EEC 9a Directive on Machine Safety D2006 42 EC Assurance of Production Quality in accor dance with ISO9001 Each mechanism is delivered with the CE stamp and a declaration of CE conformity 310 12 20 345 5 13 6 50 1 97...

Page 8: ...omatic lifting clamp and control its battery level The eMINI also displays sensor infor mation and maintenance messages Working Modes Display Information The remote can work in 2 different modes One button mode elebia button locks and unlocks the automatic lifting clamp Two buttons mode elebia button locks the automatic lifting clamp mode button unlocks the automatic lifting clamp To switch betwee...

Page 9: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Page 10: ...acity 3 hour charge 5 000 cycles 250 hours in standby mode Technical Specifications Input Voltage Output Charge Indicator Charge Complete Indicator 100 240 V AC 50 60Hz 1 0A max 12 6 V DC 1 2A No No Technology Maximum Voltage Nominal Voltage Nominal Capacity Protection Circuit Maximum Discharge Current Charge Indicator Temperature Charge Temperature Discharge Temperature Idle Weight Rechargeable L...

Page 11: ...st lock the lifting clamp by use of the eMINI remote control rigger button 3 Operator must confirm with visual inspection that all lifting clamps are blue in the LED Status Indicator 4 Crane operator confirms the locked status of the lifting clamps in the eMAX remote control 5 Lifting manoeuvring procedure can begin 1 2 4 5 OK 3 Blue LED 12 42 5ºC 1 250Kg USER 5ºC 1 250Kg 5ºC 1 250Kg 5ºC 1 250Kg i...

Page 12: ...ing clamps by use of the eMINI remote control 3 Signal operator confirms with visual inspection that all lifting clamps are green in the LED Status Indicator 4 Crane operator confirms the unlocked status of the lifting clamps in the eMAX remote control 5 Crane lifts and lifting clamps are released from load cargo 2 1 4 5 OK 3 Green LED 12 42 5ºC 1 250Kg USER 5ºC 1 250Kg 5ºC 1 250Kg 5ºC 1 250Kg i 5...

Page 13: ...he right to modify any specifications EN Working Angles Each element that conforms the load must be correctly placed on the automatic lifting clamp and firmly positioned at the end of the jaw opening Clamps must be used in pairs or múltiples thereof Make sure load is always balanced ...

Page 14: ...mer This user manual is for information only The manufacturer reserves the right to modify any specifications 14 Working angles must not exceed the maximum top angle as described in figures below a b c 30º 30º ...

Page 15: ...laimer This user manual is for information only The manufacturer reserves the right to modify any specifications EN Do not lift item load that may deflect sag Do not lift items of circular or uneven form shape ...

Page 16: ...rmation only The manufacturer reserves the right to modify any specifications 16 Do not lift item load that is pinned to any surface Do not lift item load over people Make sure people are and remain outside of the area of any sustained load ...

Page 17: ...42 EC of the European Parliament and of the Council of 22 June 1998 on the approxima tion of the laws of the Member States relating to machinery and 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility and has been manufactured in accordance with the following harmonised standards ASME B30 10 2009 ASME B30 20 2010 UNE EN 1050 UNE EN 13155 2004...

Page 18: ...ndicated on clamp or stated in the user manual Adapting and or modifying the automatic lifting clamp The injudicious use of the clamp and not succeeding all indications which are stated in the user manual When maintenance inspections have not been carried out by the authorised elebia Technical Service The manufacturer is not responsible for incidental damage or damage due to wrong use of the lifti...

Page 19: ...manufacturer reserves the right to modify any specifications EN Date Date Date Date Date Date Date Date Date Date Observations Observations Observations Observations Observations Observations Observations Observations Observations Observations Maintenance Check ...

Page 20: ...Plaça Pere Llauger Prim Naus 10 11 Polígon Industrial Can Misser 08360 Canet de Mar Barcelona Spain Tel 34 93 543 4706 www elebia com info elebia com ...