16 EN
Indicator
- night mode
In this program, the dehumidifier maintains humidity in the range of
47% - 53%
- the fan
operates at low speed.
Sound signals are disabled. In the event of overfilling of the tank, the device stops and the
indicator lights up
, but the alarm will not sound
If the ambient humidity rises above
53%
, the device will start dehumidification to the
ambient humidity of less than
47%
.
The compressor then stops and the fan will continue operating for approx. 30 seconds.
The device will restart when the humidity rises to
53%
.
If the ambient humidity of
≤53%
after connection, the device remains in standby mode
until the humidity rises to
53%
.
Button
- is used to switch the device on/off and to select the program.
OPERATION
Activation of the device
Press the button
.
If the device is connected to the power supply, the automatic program will start.
If the device has been switched off with the button
the last selected program will start.
To turn off the device, press and hold the button
for a few seconds.
Do not remove the power cord plug directly to force the device to stop directly.
PROGRAM SELECTION
The program is selected by pressing the button
until the corresponding indicator is
displayed.
The selection method is shown in
fig. 5.
EMPTYING THE TANK
ATTENTION
Water collected in the dehumidifier tank is not suitable for drinking and must not be
allowed to come into contact with food.
Do not put the floater out of water; otherwise the device will not stop working when
the water tank fills up. Then, water will overflow, which may cause damage to the
floor.
- Pull the tank gently at the back of the device; the tank will slide out (fig.6).
- Pour the water out of the tank.
- If the water tank is dirty, clean it with water. Do not use any acrid cleaning agents. Do
not use chemical solvent (such as benzene, alcohol, gasoline). The surface may be
damaged or even the whole case may be deformed. Do not sprinkle water
- Place the tank in the right position in the device. Otherwise, the full tank indicator will
still light up red and the device will not be able to work.