background image

© 

2014 eldoLED. All rights reserved. V1.1

More documentation and eldoLED’s terms and conditions are available at www.eldoled.com.

Pay attention when connecting the LED groups:
polarity reversal results in no light output and often 
damages the LEDs

POWERdrive 561/M

120-277 VAC

L

N

DMX in shield
DMX in 
DMX in +

4 LED groups
(4 control channels)

LEDcode / NTC

+

-

-

1

9 mm

0.35 inch

0.5-1.5 mm

2

AWG 20-16

 Wiring diagram POWERdrive 561/M                                                (PW0561M1)

 

WARNING: Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.

CAUTION: The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and build-
ing codes must be observed. Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.

120-277 VAC

The driver has been designed for use with universal mains voltage 
input of 120-277V AC, 50/60Hz, or with DC input of 120-250V (emer-
gency lighting).

LED groups

Indicates the location of the connectors for your LED groups. R(ed) 
represents channel 1, G(reen) represents channel 2, B(lue) rep-
resents channel 3 and W(hite) represents channel 4. The default 
group colour allocation can be changed using the TOOLbox pro and 
freely available FluxTool application.

 

Maximum wiring distance at full load (from driver to LED load):

 

LEDcode/NTC

The LEDcode/NTC interface allows connection of a 47k

Ω

 NTC therm-

istor for closed loop thermal control. The NTC throttle temperature is 
programmable through the freely available FluxTool software (see 
“Configuring your driver over DMX in”).

DMX in

Use these connectors when the driver is used in a DMX network. 
Connect the network cable’s DMX+, DMX- and DMX shielding wire 
(the orange/white, orange and brown wire in a CAT5 cable) to the 
DMX in+, DMX in- and DMX in shield connector respectively. 

Configuring your driver over DMX in

Download the FluxTool software from your eldoLED driver’s product 
web page and connect a TOOLbox pro to DMX in to configure your 
driver. You can configure:
• Various DMX parameters
• Dimming curve
• Minimum dimming level
• NTC throttle temperature
• LED drive current per output: from 200mA-1,050mA in 1mA steps

AWG value

20

19

18

17

16

Distance (m)

14

18

22

28

36

Distance (ft)

46

59

72

92

118

Please observe voltage drop over long wire lengths.