Installation
For a correct functioning of the triple technology detector it is necessary to know that:
• The microwave is sensitive to any movement, never point the
detector towards hedges or
tree fronds. Adjust the flow rate appropriately.
• Metal surfaces
reflect the microwave by changing its flow rate.
• The two passive infrared sensors are sensitive to sudden thermal variations. Avoid
pointing the detector directed towards the sun. In the presence of animals, adjust the
detection angle appropriately and always use the triple AND (3AND) condition.
• The detector at the first power supply has a stabilization time of about 1 minute.
Plugs:
Plugs AS/C-NC-NO
: Tamper. Connect C-NC for normally close, connect C-NO for
normally open.
Plugs AL/C-NC-NO
: Alarm. Connect C-NC for normally close, connect C-NO for
normally open.
Plugs
+ -
:
Power supply. Connect the battery (3/10V)
Fix the case for wireless transmitter to the wall or to the bracket, connect the wires of
the alarm input and of the tamper to the wireless transmitter and make them pass
through the appropriate hole. Close the case with the appropriate screws. Remove the
IR and microwave sensor block (4 screws) from the
detector’s case
and drill a hole for
passing cables. Fix the detector on the case for wireless transmitter. Reassemble the
sensor block. Connect the battery connectors. Perform the coverage tests.
Settings
ON
1 2 3 4
By default the setting DIP are setting as shown.
DIP1 Low battery display (SGN BAT)
ON
If the battery has a voltage lower than 2.7 V, the yellow LED flashes
rapidly every 2 s (approx.). During the walk test this signal is
interrupted
OFF
No displaing