QUICK START GUIDE  
FOR ELDES 

ESIM251

 USERS

1.  Place SIM card in the holder. 

  Make sure that PIN code at SIM card is disabled*

1

.

2.  Connect the circuit.

Connect security central system to inputs   
Z1-Z5 or any electrical device to RELAY outputs.
The system will start in less than a minute and 
LED indicator will start to blink every 5 seconds.

 

  

3.  Connect device to the computer using USB cable.

*2

4.  Run program 

ELDES Configuration Tool

  Click button 

Connect via USB

 in the main window.

5.  Change default password to a new one. 

 Select 

Users

 window and update 

Security

 section by typing a new password consisting of  4 digits.

6.  Set the English language. 

 Select 

Users

 window and update 

Language

 section.

7.  Set up to five different user phone numbers which will have access to control the system.

 Select 

Users

 window and update 

Users

 section with preferred mobile numbers according to the rules

*3.

8.  Save the preferences. Click button 

Write Settings.

9.  Set date and time.

  Click button 

Get PC Time

 which will update date and time using computer settings. Click button 

Set Clock.

10.  The system is ready to use.

*4

In this guide you will learn how to quickly 

set and run ELDES ESIM251 device  

using ELDES Configuration Tool program

. Here are the most important steps:

*1 - PIN code can be disabled by putting SIM card into mobile phone and following proper menu. *2 – If device is connected to the remaining computer for the first time, computer will run installation 
of required drivers. Then user must wait then it ends and reconnect USB cable.  *3 – User must type mobile number in the international format (it consist of only those digits that overseas callers 
must type: 44<area code><local number>) without symbol ‘+’. E.g. the mobile number of user is +44 (0) 113 xxx xxxx,  so the correct format to type is 44113xxxxxxx and the wrong ones – 
440113xxxxxxx or  0113xxxxxxx. *4 - device will use default settings set by manufacturer. The settings can be changed by user at any time.