2
2
EN
ELAN3-ALARM Ethernet Communicator
User Manual v1.1
Compatibility:
• ELAN3-ALARM v0.3 and up + ESIM364 v02.07.00 and up.
• ELAN3-ALARM v0.4 and up + ET082 v01.12.00 and up; hardware version: ET082-30 and up.
Main features:
• Supported Ethernet connectivity: 10/100 Mbit.
• Enables Internet access on ESIM364/ET082 via Ethernet interface.
• Automated configuration.
ELAN3-ALARM is an add-on device designed to use with ESIM364 alarm system or ET082 communicator and operate in IP-based net-
works. The device is an Ether net-based communicator that enables instant Internet access allowing to perform the following:
• Establish a communication between ESIM364/ET082 and EGR100 middleware, Kronos or SIA IP protocol-based monitoring station software.
• Connect ESIM364 to ELDES Smart Security platform.
• Configure ESIM364/ET082 remotely.
1. CONTENTS OF PACK
Item ................................................... Quantity
1. ELAN3-ALARM............................. ........... 1
2. User manual............................... ............. 1
Not included:
·
NSG 25-3 cable - can be obtained from your local supplier.
2. TECHNICAL SPECIFICATIONS
2.1. Electrical & Mechanical Characteristics
Power supply ..........................................................................................10-24V 50Hz ~ 210mA max. / 10-24V
210mA max.
Dimensions .............................................................................................70x85x57 mm
Operating temperature range .............................................................-20…+55 °C
Humidity .................................................................................................0-90% RH @ 0... +40 °C (non-condensing)
2.2. Main Unit, LED Indicator & Connector Functionality
FRONT SIDE
SIDE VIEW
USB
LAN
(green)
LAN
(yellow)
USB
RJ45
RS232
DEF
F1
AC/DC
Y
G
STATUS
CONNECT
RJ45
1
RS232
RS232 interface for communication
with ET082
RJ45
10/100Base-T Ethernet port
USB
Mini USB port for firmware update
DEF
Pins for fimware update
STATUS
Red light-emitting diode indicating
micro-controller status
CON-
NECT
Green light-emitting diode indicating
RS485/RS232 connectivity status
F1
miniSMDC 0,5A fuse
AC/DC
Power supply terminals
G
RS485 interface for communication
with ESIM364 (green wire)
Y
RS485 interface for communication
with ESIM364 (yellow wire)
LAN
(green)
Green light-emitting diode indicating
Ethernet activity
LAN
(yellow)
Yellow light-emitting diode indicating
Ethernet status