1.4 Connector and LED Indicator Functionality

Fig. No. 1

LEDs

STAY

STAY (perimeter security) state indicator

ARMED

ARMED (armed security) status indicator

BYPASS

BYPASS (temporary zone disconnection) status indicator

Connector Functionality

+12V

Positive supply pin +12-14 VDC connected to the main unit AUX 

DATA

Data pin connected to the main unit DATA

GND

Negative supply pin connected to the main unit GND (COM)

1.5 Keyboard installation and configuration

1. Fix the keyboard holder to the wall.
2.   Disconnect   security   system   ESIM262   power   supply   and   backup   battery   before 
connecting wires.
3. Connect keyboard connectors to ESIM262. Accordingly, +12 V must be connected 
to AUX, DATA – to DATA, GND – to GND.  
4. Infix the keyboard into the holder.
5. Turn on ESIM262 power supply.

ESC and ENT must be constantly lit.

If   not   all   security   zones   are   used,   it   is   necessary   to   use   resistors   with   the   unused   zones. 
Otherwise a red  BYPASS indicator will light up, even if a particular zone is turned off by SMS 
message or using configuration tool.

User manual EKB1 v1.0                                      

5

Note

If DALLAS key reader and/or temperature sensor are connected to ESIM262, DATA connector 
used is the same. I. e., all components containing DATA output must be connected in parallel.