background image

GB

  

Universal Receiver RCU01 (4-Channel)   

 

 

 

 

 

 

 
 
 

Models 

RCU01-4104M-01:  433.92 MHz 
RCU01-5004M-01:  868.3   MHz 
 

Package Content 

Universal Receiver incl. HF antenna, 
Mounting accessories, Screw fittings set, 
Operating instructions 
 

Technical Data 

Frequency: 

433.92 or 868.30 MHz 

Power supply: 

230 V AC / 12-24 V DC 

Output:   

4 potential-free relay 

 

 

contacts 

Max. load: 

230 V AC: see Table 

 

 

30 V DC: 3 A / 90 W 

Response time: 

approx. 1 second 

Degree of protection:    IP54 

Operating temperature: -20°C to +60°C 

Dimensions: 

150 x 110 x 50 mm 

Weight:   

approx. 500 g 

 

Intended Use 

The unit may only be used as a radio con-
trol system together with low voltage or 
mains voltage devices! 

The manufacturer shall not be liable for any 
damage caused by improper or non-
intended use! 
 

Safety Advice 

 

Warning! While being pro-
grammed, the Universal Re-
ceiver is live!   

Do not touch the terminals! Only use 
suitable tools! 

Carefully read through these instructions 
before connecting and operating the Uni-
versal Receiver! 

Electrical installation and programming  
may only be carried out by a qualified 
electrician! 

Observe the applicable laws, standards 
and regulations, particulary EN 60669! 

Caution! The primary input of the Uni-
versal Receiver must be protected by a 
50 mA fuse. 

Have faulty units checked by the manufac-
turer! 

Do not make any unauthorized alterations 
or modifications to the unit! 

Non-observance of the installation instruc-
tions may cause fire or other hazards. 

 

 

Function 

The unit is a universally applicable four 
channel radio control system, which can be 
operated both with low voltage and mains 
voltage. 

The Universal Receiver can memorize 4 
transmission codes for each channel. For 
each channel different operating modes can 
be programmed: Impulse, ON/OFF (1- and 
2-button operation), timer (30 seconds and 
3 minutes), continuous and awning opera-
tion. 
 

General Information 

Do not mount the Universal Receiver near 
the floor or near large metal objects! 

The maximum length of all connecting 
cables may not exceed 3 m. 

The reception quality can be affected by a 
number of factors: 

  location, Transmitter 

  equipment and systems without interfe-

rence suppression 

  other transmitters within the frequency 

range 

  atmospheric conditions and other fac-

tors. 

In case of malfunctions, please contact your 
dealer or the manufacturer. 
 

Connection Diagram 

 

21
22
23

24
25
26

27
28
29

30
31
32

REL1

REL2

REL3

REL4

 
 

S1 

Dip switch for memory  
location select 

DR1 

Rotary switch for 
operating mode select 

H1 

LED  

TA1 – TA4 

Programming buttons for 
channels 1-4 

REL1 – REL4 

Relays 1-4 for 
devices 1-4 

V1 – V4 

Connecting terminals for 
relays 1-4 

BU1 

Antenna socket 

ST1 

Connecting terminal for  
mains voltage 230 V AC 

ST2 

Connecting terminal for  
low voltage 12-24 V DC 

Start-Up 

Start-up the Universal Receiver in three 
steps: 

1.  Installing the Universal Receiver 

2.  Programming the operating mode 

3.  Memorizing the transmission codes 

 

Installing the Universal Receiver 

1.  Unscrew the housing cover. 

2.  Use the screws and mollies supplied, to 

mount the Universal Receiver on the 
wall. 

3.  Connect the low voltage or mains 

voltage devices to be switched to the 
connecting terminals V1 to V4 according 
to the connection plan. The connecting 
terminals are plug-type terminals. 

Max. load: 
230 V AC: 

see Table of Loads 

30 V DC: 

3 A / 90 W 

4.  Connect the power supply cables to the 

connecting terminal ST1 (mains voltage 
230 V AC) or ST2 (low voltage 12-24 V 
DC) according to the connection plan. 
The connecting terminal ST1 is a plug-
type terminal. 

Note: All cables are to be fed into the 
Universal Receiver via the openings on 
the bottom using the watertight PG 
screw fittings. 

5.  Switch on the supply voltage. The LED 

H1 lights up for approx. 1 sec. 

6.  Carry out a function check: 

Press any button of the transmitter. The 
LED H1 of the Universal Receiver 
should flash rapidly. 

 

Table of Loads (AC) 

 

Type of load 

Max. load 
230 V AC / 50Hz 

Resistive load: 
Light bulbs, 230 V 
Halogen lamps etc. 

 
 
8 A / 1,840 VA 

Inductive load: 
Halogen lamps with wound 
transformers 
(transformer at least 85% 
loaded) 

 
 
 
 
2.6 A / 600 VA 

Non-compensated or series- 
compensated fluorescent 
lamps with ferromagnetic 
ballast 

 
 
 
8 A / 1,840 VA 

Parallel-compensated 
fluorescent lamps with 
ferromagnetic ballast 

 
 
2.6 A / 600 VA 

Capacity EB: 
electronic ballast, electronic 
transformers etc. 

 
 
4 A / 920 VA 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 