RCL07E5002A21 

Technical Details

Frequency:  

868.3 MHz

Modulation:  

FSK

Coding:  

Easywave

Power supply:  

12-24 V DC

Current consumption: 
 

12 V DC: 

19 mA stand by

 

 

65 mA load *)

 

24 V DC: 

11 mA stand by

 

 

31 mA load *)

Max. contact rating: 

30 V / 1 A / 30 W

Output: 

2 potential-free    

 

relay contacts (1 CO 

 and 

1 NO)

Operating Temperature: -20 °C to +60 °C

Degree of Protection:   IP54

Dimensions (w/l/h):  

35/80/20 mm

Weight:  

38.0 g

Connecting cable: 

Ø 5 mm

*)  

Both relays are switched.

Scope of Delivery

Mini receiver RCL07, operating instructions

Intended Use

The unit may only be operated with safety extra 

low voltage (SELV) and may only be used as a ra-

dio control for switching devices with safety extra 

low voltage (SELV).
The manufacturer shall not be liable for any dam-

age caused by improper or non-intended use.

Safety Advice

 Before using the device, carefully read 

through the operating instructions!

Caution! Observe the permissible supply volt-

age and the max. contact rating!
Have faulty radio controls checked by the 

manufacturer!
Do not make any unauthorized alterations or 

modifications to the receiver!

Mini receiver   RCL07

GB

Function

The RCL07 Easywave Mini-Receiver can be op-

erated in a voltage range of 12-24 V DC. 

A total of 32 different Easywave radio transmis

-

sion codes can be memorized.

Operating modes

Via jumper J1 you can set the operating modes.

DEAD MAN 

(1-button operation)

The relay is triggered as long as the correspond-

ing transmitter button is pressed (max. 36 sec).

 

ON/OFF 

(2-button operation)

The relay can be switched ON or OFF targeted. 

The transmitter button A or C switch ON, the 

transmitter button B or D switch OFF.

IMPULSE 

(1-button operation)

If a transmitter button is pressed, the correspond-

ing relay is triggered for 1 second.

Start-Up

1.  Remove the housing cover.
2.  Select the desired operating mode with jum-

per J1. The factory setting is the IMPULSE.

3.  Connect the supply voltage and the safety 

extra low voltage devices to be switched as 

follows: 

NC1, COM, NO1, NO2

:  

CO/NO

+, 

-

 : 

Power supply 12-24V DC

J1

1

2

3

4

NC1 CO

M

NO

1

NO

2

4.  Re-install the housing cover.
5.  Transfer the codes of the transmitters to 

the receiver (see section “Programming the 

transmission codes“). 

  The receiver cannot receive EasywePlus 

telegrams, i.e. the receiver cannot be pro-

grammed with the learn button PTx of the 

Easywave radio transmitter.

Caution: 

Make sure there is no interference with 

the wireless connection. Do not mount the device 

in a distribution box, in  metal casings, in direct 

proximity  to  large  metal  objects,  on  the  floor  or 

close to it.

 

Programming the transmission codes

In the “Programming the transmission codes” 

mode you can transfer the codes of your trans-

mitter buttons to the receiver.
The selected operating mode is adopted as a re-

sult of the memorizing process and applies to the 

transmission code currently memorized. 

1.  Briefly  (<  1.6  sec)  press  the  programming 

button TA1 for channel 1 or TA2 for channel 

2. The receiver is for approx. 30 sec in the 

learning mode, the corresponding channel 

LED flashes. 

2. 

DEAD MAN 

and

 PULSE

:

 

Press and hold a 

transmitter button. 

 

ON/OFF

: Press and hold the transmitter but-

ton A or C. The code of the corresponding 

transmitter button (B/D) will be assigned au-

tomatically. 

  If the code has been memorized, the LED 

lights up and the receiver is going in the oper-

ating mode. Release the transmitter button. 

3.  Repeat step 1 and step 2 to learn in other 

transmitters.

Notice:

 In order to change the operating mode, 

first  delete  the  transmission  code  then,  using  a 

jumper to select the new operating mode and 

subsequently transfer the transmission code.

If the LED flashes rapidly for approx. 4 sec, all 32 

memory locations are occupied.

Deleting specific transmission codes

1.  Press and hold the programming button TA1 

for channel 1 or TA2 for channel 2 more than 

1.6 sec. The LED TA1 or TA2 flashes rapidly.

The receiver is for approx. 30 sec in the erase 

mode.

2.  Press the selected transmitter button. When 

the code has been deleted, the LED lights up 

and  the receiver enters the operating mode.
In the ON/OFF mode, the code of the corre-

sponding button is also deleted.

Deleting all transmission codes (Reset)

1.  Keep the programming button TA1 or TA2 

pressed for more than 1.6 sec. The LED 

flashes  rapidly.  The  receiver  is  for  approx.        

30 sec in the erase mode.

2.  Press the same programming button again 

and keep it pressed for more than 1.6 sec. 

If the memory has been deleted completely, 

the LED lights up and  the receiver enters the 

operating mode.

Notice:

 Canceling the learning operation and all 

delete operations are possible by pressing the 

button TA1 or TA2 briefly or you can wait approx. 

30 sec, until the receiver is switched to the oper-

ating mode.  

Disposal

Waste electrical products not be disposed of 

with household waste!

Dispose of the waste product via a col-

lection point for electronic scrap or via 

your specialist dealer.
Put the packaging material into the 

recycling bins for cardboard, paper and 

plastics.

Warranty

Within the statutory warranty period we under-

take to rectify free of charge by repair or replace-

ment any product defects arising from material or 

production faults.

Any unauthorized tampering with, or modifica

-

tions to, the product shall render this warranty 

null and void.

Conformity

Hereby, ELDAT EaS GmbH declares that the 

radio equipment type RTS40 is in compliance 

with Directive 2014/53/EU. 

The full text of the EU declaration of conform-

ity is available at the following internet address: 

www.eldat.de

Service

If, despite correct handling, faults or malfunctions 

occur or if the product was damaged, please 

contact your retailer or the manufacturer.

ELDAT EaS GmbH

Im Gewerbepark 14

15711 Königs Wusterhausen

Germany

Phone: + 49 (0) 33 75 / 90 37-310

Telefax: + 49 (0) 33 75 / 90 37-90

Internet: www.eldat.de

E-mail: [email protected]

Cable entry 

with cord grip

Programming 

button with LED

TA1

TA2

2

1

UM166594B  0320  D/GB

1

4 3 2

J1

J1

J1

1

4 3 2

1

4 3 2

Each type of transmitter can only be 

taught-in to the RCL07 once! 

If transmission code A or B has been 

taught-in to transmitters with 2-touch 

operation for example, buttons C and D 

cannot be used in this RCL07.