UM98546A 0913 GB
Disposal
Conformity
Service
Put the packaging material into the
recycling bins for cardboard, paper
and plastics.
Dispose of the waste product via a
collection point for electronic scrap or
via your specialist dealer.
Waste electrical products not be disposed of
with household waste!
This product conforms to the
basic requirements of the
R&TTE Directive 1999/5/EC.
Warranty
Within the statutory warranty period we undertake
to rectify free of charge by repair or replacement
any product defects arising from material or
production faults.
Any unauthorized tampering with, or modifica-
tions to, the product shall render this warranty null
and void.
For use in: EU/CH/FL/IS/N
The Declaration of Conformity can be found on
the Internet at
: www.eldat.de
General Advice
If, despite correct handling, faults or malfunctions
occur or if the product was damaged, please
contact the company at the address below:
ELDAT GmbH
Im Gewerbepark 14,
15711 Koenigs Wusterhausen, Germany
Phone:
+ 49 33 75 / 90 37-0
Fax:
+ 49 33 75 / 90 37-90
Internet: www.eldat.de E-Mail: [email protected]
The operating voltage is 230 V. The
electricity must be connected to the
permanently fitted installation by an
authorised electrically qualified person.
A safety and isolating device must be provided by
the purchaser for activating the system.
Disconnect the power supply cable from the
mains power supply before starting the
installation work.
(see
Fig. 1).
A weatherproof and UV-resistant connection
cable and data cable must be used.
The connection cables and the data cable
cross section must completely seal off the
lead-through opening in the connector
cover.
1.
Place the terminal block with the attached
cables onto the pins connector on the printed
circuit board.
2.
Snap the terminal cover onto the lower
section of the sensor housing and screw it
tight with the pan head screws provided
Mains connection:
N L
Sensor connection:
S- S+
Electrical connection
Make / interrupt connection to radio
receiver
To enable weather data to be transmitted to the
control, the weather sensor transmission code
must be programmed into the control as follows:
1.
Activate the learning mode/delete mode in
the control (refer to the instruction manual for
the control).
2.
Give the „prog“ transmit button on the sensor
a short press; the LED will light up. The
transmission code is transmitted to the
control and the connection between the
control and the sensor has been made or
deleted.
3.
Set the desired threshold value.
The setting for the threshold value
depends upon the size and
type of
awning and on local conditions. Please
take into account the wind resistance
class for your awning!
Set threshold value for wind
Set threshold value for light intensity
(only SWSR01-W and SWS01-W)
The sensor continuously measures wind speeds
between 3 km/h und 50 km/h. Within this range,
the wind value (threshold value) can be selected
individually.
The currently measured value and the threshold
value that has been set are transmitted to the
radio receiver at 12-minute intervals. If there is a
significant increase in the wind
, the value
measured is transmitted immediately.
The awning is then operated as prescribed by the
control.
The factory setting for this value is 11
km/h.
Turn the hand wheel of the potentiometer until the
desired threshold value is obtained.
(
³
21%)
The sensor measures the light intensity
periodically within the range of 1 lux to 100klux.
Within this range, the light intensity value
(threshold value) can be selected individually.
The currently measured value and the threshold
value that has been set are transmittted to the
radio receiver at 3-minute intervals.
Turn the hand wheel of the potentiometer until the
desired threshold value is obtained.
If the measured value is above or below the
threshold value, then the awning is operated as
prescribed by the control.
The
factory setting for this value is 10 klux.
Rain detection
(only SWSR01-W)
Gastronomy function
only SWSR01-W
The rain sensor surface is continuously
monitored. The status is transmitted to the control
every 12 minutes. If the status changes from wet
to dry or vice versa, this information is
immediately transmitted to the radio receiver.
The awning is then operated as prescribed by the
control.
The indirekt heating of the rain sensor surface
allows the surface to dry quickly.
The procedure for switching the „gastronomy
function“ ON/OFF is as follows.
1. Press the „prog“ button until the LED flashes.
2. Press the „prog“ button to switch the
gastronomy function ON or OFF.
3. Finally, press the „prog“ button again until the
LED goes off.
prog
+
_
+
_
3
50
km/h
11
19
27
34
42
Wind speed km/h
1
3
Light air
2
11
Light breeze
3
19
Gentle breeze
4
27
Moderate breeze
5
34
Fresh breeze
6
42
Strong breeze
7
50
High wind
prog
+
_
+
_
1
100k
Lux
10
100
1k
10k
Light intensity in lux
100k
Bright sunny day
20k
Dull sunny day
10k
In the shade in summer
3,5k
Dull winter day
prog
Gastronomy function
OFF
ON
...
...
Single flash
Double flash
prog
+
_
+
_
prog
_
10 mA IP43
50Hz
230 V
N
L
-
S
+
S
Transmit
button
RCJ05