curve 3), cut off the power and reconnect it.
Alarms
LED Flashing Sequence(One Cycle)
Indication
1
R G _ _ _ _ _ _
Wrong Battery
2
R G R _ _ _ _ _
Overcharged
3
R G R G _ _ _ _
The temperature of battery is too high
4
R G R G R _ _ _
Incorrect AC Input Voltage
5
R G R G R G _ _
The thermal sensor of charger is in fault
6
R G R G R G R _
The interface of communication is in fault
7
G R _ _ _ _ _ _
The temperature of charger is too high
8
G R G _ _ _ _ _
The relay of charger is in fault
;
Repair
9
G R G R _ _ _ _
Charger is in fault; Repair
Note:
1. R—red G—green
2. “_” denotes one second stop.
3. Above LED flashing sequence is just one cycle, the LED will flash
repeatedly when in fault.
Installation & Safety Instructions
Our charger has been designed to provide safety and reliability. It is important to
observe the following precautions and installation instructions in order to avoid
damage to persons and to the battery charger. For further reference keep the
instruction in a proper place.
1. Fix the battery charger to a stable surface with the holes inserted on the mounting
tabs. In case of installation on a vehicle, it is advisable to use anti-vibration supports.
2. Preferably the charger should be installed in the vertical position with radiator fins
vertical. A space of 10cm above ground should be vacated, to ensure it is ventilated.
Never install in the vertical position with fins facing down. Refer to drawing below:
3. Ensure all heat dissipating parts are not obstructed to avoid overheating. Do not
put the battery charger near any heat sources. Make sure that free space around the
battery charger is sufficient to provide adequate ventilation and easy access to cable
sockets.
4. For safety and electromagnetic compatibility the battery charger has a 3-prong
plug that will only plug into a proper grounded outlet.
5. To avoid damaging the power cord, do not put anything on it or place it where it
will be walked on. If the cord becomes damaged or frayed, replace it immediately.
6. If you are using an extension cord or power strip, make sure that the total of the
amperes required by all the equipment on the extension is less than the extension’s
3