AC Input 

AC Input Voltage - range 

90 - 260VAC 

AC Input Voltage - nominal 

120 VAC / 230 VAC 

AC Input Frequency 

45 - 65 Hz 

AC Input Current - maximum  15A 

Current – nominal 

14 A rms @ 120 VAC / 9.5 A rms @ 230 VAC 

AC Power Factor - nominal 

> 0.98 

Mechanical 

Dimensions 

352mm

×

195mm

×

139mm   

Weight 

< 7 kg    Standard output cord 

Environmental Enclosure 

IP46 

Operating Temperature 

-30°C to +50°C (-86°F to 122°F) 

Storage Temperature 

-40°C to +85°C (-104°F to 185°F) 

LED Indicator   

Red-Green flash (one second interval) 

Battery Disconnected

 

Red flash (three seconds interval) 

Repair Battery

 

Red flash (one second interval) 

<80% Charge Indicator

   

Yellow flash (one second interval) 

>80% Charge Indicator

 

Green flash (one second interval) 

100% Charge Indicator

 

Protection Features 

1.Thermal  Self-Protection:  When  the  internal  temperature  of  the  charger  exceeds 
80

, the charging current will reduce automatically. If exceeds 85

, the charger will 

shutdown  protectively,  there  is  no  current  output  in  this  case.  When  the  internal 
temperature drops to 80

, it will resume charging automatically. 

2. Short-circuit Protection: When the charger encounters unexpected short circuit 
across the output, charging will automatically stop. By cutting AC power for 10 
seconds,  the  charger  can  be  re-set  and  will  start  normally(with  the  output  circuit 
corrected)   
3. High and Low Voltage Protection: When the input AC Voltage is higher or lower   
than the rated input voltage range, the charger will shutdown protectively, but resume 
working after the voltage is normal again. 

Inter-lock Function

 

 