2
AC Input
AC Input Voltage - range
90 - 260VAC
AC Input Voltage - nominal
120 VAC / 230 VAC
AC Input Frequency
45 - 65 Hz
AC Input Current - maximum 15A
Current – nominal
14 A rms @ 120 VAC / 9.5 A rms @ 230 VAC
AC Power Factor - nominal
> 0.98
Mechanical
Dimensions
352mm
×
195mm
×
139mm
Weight
< 7 kg Standard output cord
Environmental Enclosure
IP46
Operating Temperature
-30°C to +50°C (-86°F to 122°F)
Storage Temperature
-40°C to +85°C (-104°F to 185°F)
LED Indicator
Red-Green flash (one second interval)
Battery Disconnected
Red flash (three seconds interval)
Repair Battery
Red flash (one second interval)
<80% Charge Indicator
Yellow flash (one second interval)
>80% Charge Indicator
Green flash (one second interval)
100% Charge Indicator
Protection Features
1.Thermal Self-Protection: When the internal temperature of the charger exceeds
80
℃
, the charging current will reduce automatically. If exceeds 85
℃
, the charger will
shutdown protectively, there is no current output in this case. When the internal
temperature drops to 80
℃
, it will resume charging automatically.
2. Short-circuit Protection: When the charger encounters unexpected short circuit
across the output, charging will automatically stop. By cutting AC power for 10
seconds, the charger can be re-set and will start normally(with the output circuit
corrected)
3. High and Low Voltage Protection: When the input AC Voltage is higher or lower
than the rated input voltage range, the charger will shutdown protectively, but resume
working after the voltage is normal again.
Inter-lock Function