12 MENU STRUCTURE

Menu

Delete Last Reading
Dolly Size / Pull Rate
Setup
Verify Calibration
About
Reset
Emergency Light

Setup

Language
Time and Date
Beep Volume
Screen Settings
Units
Gauge Auto Off

Time and Date

Set Time
Set Date
Set Format
Display Time and Date

Screen Settings

Screen Brightness
Screen Timeout
Opening Screen
Screen Rotation

Units

MPa
psi
Newtons

2

N/mm

About

Gauge Information
Contact
Legal

Legal

Legal Notices
Regulatory

Display

Setup Display
Statistics

Setup Display

Top Display
Bottom Display

Top Display

None
Selected Stats
Run Chart
Readings




Statistics

Clear Statistics
View Selected
View All
Select Statistics



Select Statistics

Number of Readings
Mean
Lowest Reading
Highest Reading
Range
Standard Deviation
Coefficient of Variation







Batch

Memory Free                  xx.x%
New Batch
Open Existing Batch
Exit Batching
Edit Batch
Review Batch
Deleted Reading

New Batch

Open Batch n
Dolly Size & Pull Rate
Cutting Device
Skirt Type

Dolly Size

10 mm
14.2 mm
20 mm
50 mm




Cutting Device

None
Dolly Cutter
Knife



Skirt Type

Standard 20 mm
Standard 50 mm
Thin Substrate 14.2 mm
Thin Substrate 20 mm



Edit Batch

Clear Batch
Delete Batch

Review Batch

Statistics
Batch Information
Readings

Deleted Reading

Delete With Tag
Delete Without Tag


Dolly Size

10 mm
14.2 mm
20 mm
50 mm




Pull Rate

x.xx

MPa/s

Regulatory

 

 

    xxxxx

 

 

xxxxx

 

 

xxxxx

Bottom Display

None
Selected Stats
Run Chart
Readings




Summary of Contents for 510 S

Page 1: ...User Guide Elcometer 510 Model S Automatic Adhesion Tester en R www elcometer com...

Page 2: ...to the original English language version Gauge Dimensions 260 x 100 x 66mm 10 3 x 3 9 x 2 6 Gauge Weight With 10mm 14 2mm 20mm Standard Dolly Skirt 2 9kgs 6 4lbs With 50mm Standard Dolly Skirt 3 1kgs...

Page 3: ...trates are also available see Section 14 3 Dolly Skirts on page 20 for details 1 Actuator 2 Lanyard Ring 3 Shoulder Strap Connections 4 Battery Compartment 5 LED Indicators Red left Green right 6 Mult...

Page 4: ...lly Standard Skirt 50mm Dolly Standard Skirt 20mm Dolly Cutter Handle 50mm Dolly Cutter with DrillArbor 2 BOX CONTENTS www elcometer com 3 en R 3 USING THE GAUGE a Red LED b Green LED c Power Batterie...

Page 5: ...cometer com 4 k Batching On l Last Reading greater than symbolizes Did Not Fail m Actuator Load Value n User Selectable Statistics 4 rows o Batch Name when in batching p Run Chart last 20 readings use...

Page 6: ...urs Care should be taken to ensure the correct polarity when fitting the batteries into the charger The battery condition is indicated by the battery symbol at the top right of the display When there...

Page 7: ...by the user via Menu Setup Screen Settings including Screen Brightness This can be set to Manual or Auto the brightness is adjusted automatically using the gauge s ambient light sensor Screen Timeout...

Page 8: ...e softkeys to highlight the required option and press Select If None is selected for one half and Readings or Run Chart for the other half the readings or run chart will fill the whole the screen If a...

Page 9: ...0mm 0 20 0 30 0 70 1 00 1 20 30 50 100 150 180 65 95 220 315 380 0 20 0 30 0 70 1 00 1 20 50mm 0 04 0 08 0 12 0 16 0 20 5 8 16 24 30 80 160 235 315 400 0 04 0 08 0 12 0 16 0 20 5 SECURING THE DOLLY 5...

Page 10: ...test area is not 4 subjected to twisting or torque To minimise heat and suppress dust water lubrication may be required 2 Follow steps 1 4 in Section 5 1 making sure the dolly is positioned inside the...

Page 11: ...d pressure has been reached eg 25MPa for a 20mm dolly At this point the gauge re winds to zero and the user is asked if they wish to save the reading 4 indicates a reading outside of range 4 If the ma...

Page 12: ...incorrect or insufficient mixing of the component parts of the adhesive incompatibility between the adhesive the coating the dolly and or the test surface see Section 5 Securing the Dolly on page 8 fo...

Page 13: ...tween different layers of the coating Adhesive Failure Partial Coating Failure Concrete Failure Coating Failure 9 BATCHING 9 1 BATCH FUNCTIONS The Elcometer 510 Model S gauge can store up to 60 readin...

Page 14: ...e included on any report within ElcoMaster For further information on ElcoMaster 2 0 visit www elcometer com To create a new batch select Batch New Batch and add the following criteria as required Dol...

Page 15: ...and can be viewed at any time via Batch Review Batch Batch Information Batch Information Batch 1 Created Date Last Verified Time Last Verified Pull Rate Dolly Size Cutting Device Skirt Type Back 15 31...

Page 16: ...hat the resulting calculation is for guidance only 10 2 BATCH READINGS Batch Review Batch Readings Displays all measurement data for each individual reading within the batch including The reading valu...

Page 17: ...5 Compare the test load with the reading on the Elcometer AVU display If the Elcometer AVU reading is within the acceptable range displayed in brackets underneath the test load press Ok to proceed to...

Page 18: ...Clear Statistics View Selected View All Select Statistics Select Statistics Number of Readings Mean Lowest Reading Highest Reading Range Standard Deviation Coefficient of Variation Batch Memory Free x...

Page 19: ...can be used with a range of dollies also referred to as test elements or stubs d 10 14 2 20 and 50mm diameter dollies are available to purchase as an optional accessory 10mm ideal for testing up to 10...

Page 20: ...test methods will determine if the Inspector should cut score around the dolly prior to test to separate the test area from the rest of the coating information which should be recorded with the result...

Page 21: ...n For Dolly Sizes mm Integrated Support Sales Part Number Ring Dimensions I D O D Standard Skirt 10mm 14 2mm 20mm 30mm 40 4mm T999101420S Thin Substrate Skirt 14 2mm T9990014T 16 3mm 40 4mm Thin Subst...

Page 22: ...dhesive must be disposed of as special waste unless it has been fully cured To dispose of excess adhesive at the end of its shelf life simply mix the remaining material and allow it to cure before dis...

Page 23: ...Pressure Rating 26MPa 3800psi Pressure Resolution 0 01MPa 1psi Pressure Accuracy 1 of full scale Pull Rate Range 1 0 5 0MPa s 125 725psi s 0 4 2 5MPa s 60 360psi s 0 2 1 2MPa s 30 180psi s 0 04 0 20MP...

Page 24: ...skirt fitted 85mm 3 4 14 2mm skirt fitted 85mm 3 4 20mm skirt fitted 110mm 4 3 50mm skirt fitted Can be used in accordance with ASTM C1583 ASTM D4541 ASTM D7234 12 AS NZS 1580 408 5 BS 1881 207 DIN 1...

Page 25: ...Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio freq...

Page 26: ...en R www elcometer com 25...

Reviews: