03/2005 - Art. Nr. 13 018 067A
22
Function
Layout plant
Connection base
20
21
10
1/8
4/2
4
2
11
22
6
5
23
-/4
25
26
1
2
3
4
7
8
9
10
11
12
18
19
20
15
16
17
18
19
20
22
23
24
25
18
19
18
19
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
54
55
56
Terminal
Description
Terminal
Description
1
Terminal A of control unit
31
Terminal B of control unit via terminals T6 and T7 (if
1-stage) at Wiel.-plug. 4P. (1 of SM-plug)
2
Terminal 9 of control unit
32
Terminal C of control unit (2 of SM-plug.)
3
Terminal 7 of control unit
33
Terminal T1 at Wiel.-plug. 7P. (2 of SM-plug)
4
Neutral
34
Terminal B5 at Wiel.-plug 4P. (4 of SM-plug) and phase of
valve 2
7
Terminal 5 of control unit
35
Terminal B4 at Wiel.-plug 7P. (5 of SM-plug) and phase of
valve 1 (terminal 5 of control unit)
8
Earth (ground)
36
Neutral (6 of SM-plug)
9
Neutral
37
Terminal 3 of control unit
10
Terminal 4 of control unit
38
Terminal 6 of control unit (8 of SM-plug) (if bridge between
4 and 6 or if heating system is warm, then terminal 4 und 6)
11
Earth (ground)
39
Terminal B of control unit via terminals T6 and T8 at
Wiel.-plug 4P. (9 of SM-plug)
12
Neutral
40
Phase
15
Terminal 1 of control unit
41
Earth (ground)
16
Terminal 2 of control unit
42
Neutral
17
Terminal 9 of control unit
43
Terminal 5 of control unit (valve)
18
Terminal B5 at Wiel.-plug 4P. and terminal 4 of SM-plug
44
Terminal 6 of control unit (heating)
19
Earth (ground)
45
Terminal 4 of control unit (heating contact)
20
Neutral
46
Earth (ground)
22
Terminal 5 of control unit and terminal B4 at Wiel.-plug 7P.
(Counter 1
st
stage)
47
Neutral
23
Terminal B5 at Wiel.-plug 4P.and terminal 4 of SM-plug
(Counter 2
d
stage)
48
Terminal T8 at Wiel.-plug 4P.
24
Neutral
49
Terminal T6 at Wiel.-plug 4P.
25
Phase
50
Terminal T7 at Wiel.-plug 4P.
26
Phase
51
Terminal T2 at Wiel.-plug 7P.
27
Earth (ground)
52
Terminal 9 of control unit
28
Neutral
54
Phase
29
Neutral
55
Earth (ground)
30
Terminal 3 of control unit
56
Neutral
Terminal
Plug no
Terminal
Plug no
Plug no
Terminal
Plug no
Terminal
Remote reset
Malfunction
display
Air-pressure
switch
Solenoid
valve I
Burner motor
Flame
c
heck
Solenoid
valve
II
Operating-hour
counter
Ignition
Servomotor
Power
s
upply
L
1
Contin.
flow
ventilation
Regulator
Summary of Contents for L 03.240 DUO
Page 30: ......
Page 32: ...03 2005 Art Nr 13 018 067A 32...
Page 36: ...03 2005 Art Nr 13 018 067A 36...
Page 40: ......
Page 41: ...41 03 2005 Art Nr 13 018 067A...
Page 42: ...03 2005 Art Nr 13 018 067A 42...
Page 43: ...43 03 2005 Art Nr 13 018 067A...