ELECTRICAL MULTIFUNCTION METER 

GENERALITY 

 

ELM-4D1P 

instruction manual

IM443-U v0.7 

pag. 1

 

These digital multimeters allow to monitor all the electrical parameters 

present on a distribution line. The local display of 30 electrical parameters 
is carried out by 4 display with red LED guaranteeing a good and 
contemporary reading of more measures. A simple front panel completes 
the intuitive selection of several electrical parameters, with a great quantity 
of information. These instruments, over of the instantaneous measures, 
display the maximum peak of the main parameters (maximum peak and 
maximum   demand).   The   presence   of   the   serial   port   communication 
EIA485 (option) allows the connection in network of more instruments to 
realize centralized measure networks. 
These   multimeters   replace   in   a   unique   device,   all   the   functions   of 
voltmeters, ammeters, energy meters, cosphimeters, wattmeters, 
varmeters, frequency meters permitting a great economic saving, a reduction of dimension and the wiring energy and 
a simplification in the purchase and management of the instruments because this is a model usable at all of need of 
local measure in the electrical panel, machine, etc. 

 

AVAILABLE MODELS

 

It’s available one model for DIN rail mounting. 
-  ELM-4D1P-485A basic version in execution for DIN rail mounting 35   

mm with serial output (RS485) and with analog output 

 

OPTIONS

 

- Power Supply: 20÷60 Vac / 24÷72 Vcc (-C1) 
- Power Supply: 85÷230 Vac / 90-250 Vcc (-C2) 
- Insulated current inputs (-T) 

 

MEASURED PARAMETERS

 

parameters

 

unit of measurement

 

initial identification

 

phase and three phase voltages

 

[V-kV]

 

L1-N 

L2-N 

L3-N 

Σ

 

L-N

 

phase to phase and three phase system voltages

 

[V-kV]

 

L1-L2 

L2-L3 

L3-L1 

Σ

 

L-L

 

phase and three phase currents

 

[A-kA]

 

L1 

L2 

L3 

Σ

 

A

 

neutral current

 

[A-kA]

 

A

 

 

phase and three phase power factors

 

PF 

L1 

PF 

L2 

PF 

L3 

Σ 

PF

 

phase and three phase active powers

 

[W-kW-MW]

 

L1 

L2 

L3 

Σ 

W

 

phase and three phase system reactive powers

 

[VAr-kVAr-MVAr]

 

VAr 

L1 

VAr 

L2 

VAr 

L3 

Σ 

VAr

 

phase and three-phase system apparent powers

 

[VA-kVA-MVA]

 

VA 

L1

VA 

L2 

VA 

L3 

Σ 

VA

 

 

frequency

 

[Hz]

 

Hz 

L1

 

temperature

 

[°C]

 

T

 

three phase system active energy

 

[kWh]

 

Σ

 

kWh

 

three phase system reactive energy

 

[kVArh]

 

Σ

 

kVArh

 

three phase system apparent energy

 

[kVAh]

 

Σ

 

kVAh

 

hour counter

 

[hr]

 

h

 

average and peak values (maximums):

 

maximum phase voltages

 

[V-kV]

 

L1-N max 

L2-N max 

L3-N m x

 

a

maximum phase currents

 

[A-kA]

 

L1 m x 

L2 max 

L3 max

 

a

maximum neutral current

 

[A-kA]

 

A

n max

 

maximum three-phase powers

 

[W-VAr-VA (k-M)]

 

Σ

 

max 

Σ

 

VAr 

max 

Σ

 

VA 

max

 

maximum average phase currents (maximum demand)

 

[A-kA]

 

L1 max (avg

L2 max (avg) 

L3 max (avg)

 

maximum average neutral current (maximum demand)

 

[A-kA]

 

A

n max (avg)

 

maximum average three-phase powers (maximum demand)

 

[W-VAr-VA (k-M)]

 

Σ

 

max (avg) 

Σ

 

VAr 

max (avg) 

Σ

 

VA 

m x (avg)

 

a

average phase currents

 

[A-kA]

 

L1 a g 

L2 avg 

L3 avg

 

v

average neutral current

 

[A-kA]

 

A

n avg

 

average three-phase powers

 

[W-VAr-VA (k-M)]

 

Σ

 

avg 

Σ

 

VAr 

avg 

Σ

 

VA 

avg

 

Summary of Contents for ELM-4D1P

Page 1: ...485 and with analog output OPTIONS Power Supply 20 60 Vac 24 72 Vcc C1 Power Supply 85 230 Vac 90 250 Vcc C2 Insulated current inputs T MEASURED PARAMETERS parameters unit of measurement initial ident...

Page 2: ...Vac dc version Terminals Power Supply Terminals Power Supply Terminals Power Supply 19 20 0 110V 100 125Vac 50 60Hz 19 21 0 230V 220 240Vac 50 60Hz 19 23 0 400V 380 415Vac 50 60Hz 19 21 20 60Vac 24 7...

Page 3: ...WIRING DIAGRAMS W ELM 4D1P instruction manual IM443 U v0 7 pag 3...

Page 4: ...internalCT S1 I1 S2 auxiliary power supply S1 I2 S2 S1 ELM I3 S2 VL1 VL2 VL3 N with Ineutral option In VL1 VL2 VL3 N L1 S1 L2 P1 L3 S1 S2 L1 L2 L3 S1 S2 N P1 P2 P1 P2 CT connection to Voltage insertio...

Page 5: ...lay indicates also the values of the active and reactive energy counters Using the A and B keys the display indicates the maximum and average values G display for the visualization of the electrical m...

Page 6: ...ynchronism 50 type 60 version with digital output seT PUL SE 10 0 kW kVAr pulse Set pulse weight 01 0 kW kVAr pulse 0 10 kW kVAr pulse 0 01 kW kVAr pulse version with digital output seT TPL Increase f...

Page 7: ...of the CT rate will be possible to set this value example with CT 1000 5the value will be 200 Pressing the A key confirm and go away with the next setting Programming of the average time seT AVG T Aft...

Page 8: ...e password is wrong the message PASS ERR will appear on F display and the instrument go back to the measures visualization To input the password when required by the instrument at the enter of the set...

Page 9: ...tput will function as alarm verifying that the maximum value of the single phases doesn t exceed the maximum threshold set ALR HI and that the minimum value of the single phases doesn t come down the...

Page 10: ...the set SET THE HIGH AND THE LOW THRESHOLDS On F display will appear the message ALR Hi with the high threshold value confirming with the A key on the same display will appear the message ALR LO with...

Page 11: ...ing the C key the message SET AN OUT will appear on the F display To accede to the menu programming press the A key the message SET will appear on the G display on the F display and on D led bar will...

Page 12: ...key to select the parameter and the A key to confirm it SET THE THRESHOLD Subsequently it s necessary to set the threshold using the B to increase and C to decrease keys Confirm with A key I O INFO P...

Page 13: ...the measures appear on the L1 display Visualization section 2 At the same way of the section 1 press the C button to select the parameter that can be displayed and indicated from E LED The voltage va...

Page 14: ...er maximum three phase powers max maxD avg I L1 max avg I L2 max avg I L3 max avg I N max avg phase and neutral currents maximum of average phase and neutral currents max demand max maxD avg W max avg...

Page 15: ...electrically disturbed it is suggested to use 100 120ohm 1 2W resistors placed between the common of the RS485 outlet and the shielded cable For other information on the serial line it s better to se...

Page 16: ...auto consumption 0 5VA INPUTS OUTPUTS digital outputs Two outputs with common optomos 12 230Vac dc max 150mA insulation 3kV for 60 seconds Pulse Function Weight programmable 0 01 0 1 1 10 kWh pulse P...

Reviews: