4. Features  

• 14 functions measure Sound level, Light, Humidity, Temperature, DC 
Voltage, AC Voltage, DC Current, AC Current, Resistance, Diode and 
Continuity test.  
• 3 4/5Digital large LCD display with units of Lux, °C, %RH and dB indication.  
• Easy to use with single function switch operating, pocket size and light 
weight.  
• Sound level measures from 35dB to 100dB for C weighting checking with 
0.1dB resolution.  
•  Light measuring levers ranging from 1 Lux to 40,000 Lux.  
•  Humidity measurement from 30%RH to 90%RH with 1%RH resolution and 
fast time response.  

5. Specifications  

Display:  

 

3 4/5Digital 4000 counts LCD display with function of 

Lux, °C, % and dB indication. 
Polarity:  

 

Automatic, ( ) negative polarity indication. 

Over-range:  

 

"OL" mark indication. 

Low battery indication:   The "" is displayed when the battery voltage drops 
below the operating level. 
Measurement rate:  

3 times per second, nominal.  

Operating environment: 0°C to 40°C(32°F to 104°F) at <70%RH  
Storage temperature:   -10°C to 60°C (14°F to 140°F) at <80%RH 
Power:   

 

One standard 9V, NEDA1604 or 6F22 battery.  

Dimensions:    

170 (H)x78(W) x48(D) mm  

Weight: Approx.:  

335g including holster.  

Accuracy is given at 18°C to 28°C (65°F to 83°F), less than 70%RH. 
5-1  Sound Level  
Measurement range:    

 

35 to 100dB 

Resolution: 

 

   0.1dB 

Typical instrument frequency range:  

30Hz to 10kHz  

Frequency Weighting:    

 

C — weighting  

Time Weighting:  

 

 

Fast 

Accuracy:  

 

 

 

±5dB at 94dB sound level, 1kHz sine 

wave. 
Microphone: 

 

   Electric 

condenser 

microphone. 

 

5-2 Light  
Measuring 

Range: 

 

  4000, 

40,000Lux (40,000Lux range 

reading xl 0) 

Overrate Display:  

 

 

Highest digit of "OL" is displayed . 

Accuracy:  

±5% rdg +10 dgts (calibrated to standard incandescent lamp 

at color temperature 2856k). 
Repeatability: 

 

   ±2% 

 

Temperature Characteristic:  

 

±0.1% °C 

Photo detector:   

 

One silicon photo diode with filter.  

5-3 Temperature/Humidity 
K-type temperature Measurement  
Range Resolution 

Accuracy 

-20°C to 400°C  

0.1°C 

3% of rdg +3°C 

-20°C to 1300°C 

1°C 

3% of rdg +3°C 

Input Impedance: 10MQ  
Overload Protection: 250VDC or AC rms. for 400mV range and 250VDC or 
250VAC rms. for other ranges. 
Indoor Temperature Range  
Range Resolution 

Accuracy 

0°C to 50°C 

0.1°C 

3% of rdg + 3°C 

Indoor Humidity Range 
Range Resolution 

Accuracy 

33% RH to 99%RH 

1%RH 

3% of rdg + 5%RH 

Input Impedance: 10MQ  
Overload Protection: 250VDC or AC rms. for 400mV range and 250VDC or 
250VAC rms. for other ranges. 
 
5-4 Multimeter  
DC Voltage (Auto-ranging) 
Range Resolution 

Accuracy 

400.0mV 0.1mV 
4.000V 1.0mV 
40.00V 10mV 

±1.0% of rdg ±4dgts 

100.0V 100mV 
250V 1V 

±1.0% of rdg ±4dgts 

Input Impedance: 10MO.  
Overload Protection: 250VDC or AC rms. for 400mV range and 250VDC or 
250VAC rms. For other ranges.  
 
 

ELCART DISTRIBUTION SPA  via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY

Tel. ++39(0)2/25.11.73.10 Fax ++39(0)2/25.11.76.10 sito internet:  www.elcart.com    e-mail: [email protected]

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

Summary of Contents for Nimex NI-8002

Page 1: ...C Current 6 8 Measuring AC Current 6 9 Measuring Capacitance 6 10 Measuring Frequence 6 11 Measuring Resistance 6 12 Measuring Diode 6 13 Audible Continuity Test 6 14 Non contact AC Voltage Test NCV 7...

Page 2: ...measurement and Audible Continuity Diode Temperature test 2 Safety Instructions This meter has been designed for safe use but must be operated with caution The rules listed below must be carefully fol...

Page 3: ...n to select AC or DC measurement when in Voltage ranges 15 REL button The relative measurement feature allows you to make measurements relative to a stored reference value A reference voltage current...

Page 4: ...icrophone Electric condenser microphone 5 2 Light Measuring Range 4000 40 000Lux 40 000Lux range reading xl 0 Overrate Display Highest digit of OL is displayed Accuracy 5 rdg 10 dgts calibrated to sta...

Page 5: ...2 dgts 10 00 10mA 2 0 of rdg 5 dgts Overload Protection 15 seconds maximum 250V DC or 250V AC rms on all ranges Maximum open circuit voltage 2 8V Capacitance Auto ranging Range Resolution Accuracy 50...

Page 6: ...the photo detector from the light source Spectral sensitivity characteristic To the detector the applied photo diode with filters makes the spectral sensitivity characteristic almost meet CIE Internat...

Page 7: ...DC set the function switch to the yellow 10A position and insert the red test lead banana plug into the 10A jack Press the MODE button to indicate DC on the display Remove power from the circuit unde...

Page 8: ...Voltage Test NCV Set the function switch to the ON position Remove the meter and face the NCV detector to ACV source If source voltage in 200 1000V the NCV indicate lamp will light 7 Maintenance Batte...

Page 9: ...CA 6 7 Misurazione Corrente CC 6 8 Misurazione Corrente CA 6 9 Misurazione Capacit 6 10 Misurazione Frequenza 6 11 Misurazione Resistenza 6 12 Misurazione Diodi 6 13 Test Continuit 6 14 Non contact A...

Page 10: ...misura di resistenza e continuit diodo e prove di temperatura 2 Informazioni di sicurezza Questo strumento stato progettato per un utilizzo sicuro ma deve essere gestito con cautela Le norme sotto ind...

Page 11: ...re DC quando si agisce nei campi di azione A mA uA e 14 Pulsante RANGE Pulsante per la selezione di misurazione AC oppure DC quando e presente tensione per i campi di azione di 15 Pulsante REL La funz...

Page 12: ...condensatore elettrico 5 2 Luce Gamma di misurazione 4000 40 000 Lux 40 000 Lux di gamma lettura x 10 Indicatore Sovraccarico Viene visualizzato il simbolo OL Precisione 5 rdg 10 cifre calibrato per...

Page 13: ...of rdg 2 dgts 400 0 100uA 1 5 of rdg 2 dgts 10 00 10mA 2 0 of rdg 5 dgts Protezione da sovraccarico 15 secondi massimo 250V CC o 250V CA rms per tutte le gamme Massima tensione a circuito aperto 2 8...

Page 14: ...d ingresso troppo forte e dovete selezionare una gamma di misurazione pi alta Quando la misurazione stata completata Togliere il lettore ottico dalla sorgente luminosa Caratteristica di sensibilit sp...

Page 15: ...ollegare i puntali in serie al circuito da misurare Alimentare il circuito Leggere il valore sul display 6 8 Misurazione corrente CA Inserire il puntale nero nel terminale COM e il puntale rosso nel t...

Page 16: ...ima di tentare di aprire il vano assicurarsi che i puntali siano scollegati dal circuito di misura per evitare scosse elettriche Sostituire il fusibile solo con fusibili con le stesse caratteristiche...

Reviews: