Manuale di istruzioni/Scheda tecnica
La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.
The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.
La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.
ART. 09/06015-00
PAGINA 2 DI 2
Non-contact Alternating Voltage Tester
Operation Manual
ART. 09/06015 NI 405
Warning
Special attention is required when using this device, because the improper
use may cause damages to this device or bodily injuries. Please fully abide
by the safety rules and safety measures as provided for herein.
Structural Diagram:
①
Probe (NVC sensor)
②
Power switch
③
Electric torch switch
④
Induced voltage indicator lamp
⑤
Signal intensity indicator lamp (low)
⑥
Signal intensity indicator lamp (moderate)
⑦
Signal intensity indicator lamp (strong) - red
⑧
Electric torch illumination lamp
Operating instructions:
AC Voltage Detection
Turn on the instrument's power switch
②
, and the power indicator lamp
(white) illuminates. Allow the instrument's probe to contact the power socket
orto get near the live wire. If the instrument detects AC voltage, its induction
indicator lamp
④
will flash.
The relevant signal intensity indicator lamps (low, mid, high) light up,
depending on the signal intensity detected, and the buzzer makes the
different alarm sound.
• if the instrument detects common AC signal, the signal intensity
indicator lamp (low) alone lights up;
• if it detects higher AC signal, the signal intensity indicator lamps (low,
mid) both light up;
• if it detects highest AC signal, the signal intensity indicator lamps (low,
mid, high) all light up.
Warning
1. If the AC voltage is detected, this indicates the presence of voltage, even
though there is no alarm indication. The presence of voltage cannot be
judged by the non-contact voltage tester. The detecting operation may
be affected by such factors as socket design, insulation thickness and
insulation type.
2. Before the instrument is used for detecting the AC voltage of the power
socket etc, the test pencil should be tested on the given live circuit, to
make sure that it may work well.
Specifications:
Technical indicators
Range of AC voltage
12 -1000V
Frequency
50 Hz/60Hz
Alarm mode
Sound and light alarm
Electric torch
White LED illumination lamp
Auto shutdown
⎷
Low-voltage indicator lamp
⎷
Zero/live line judgment
Sound (different frequency) and LED lamp
NCV sensitivìty
Selecting 3 types of sensitivity automatically
(low, mid, high)
NCV sensitivity indication
mode
The instrument uses the alarm sound
of different frequency and LED lamp of
different color to indicate low, moderate or
high sensitivity
General Parameters
Power source
2x1.5V AAA cell
Product size
156x20x20 mm
Product weight
45 gr.
Security level
CE CATIII 1000V/CAT.IV 600V
Service temperature
0°C÷+40°C
Storage temperature
-10°C÷+50°C
Altitude
<2000m
Auto Shut-Down
If the instrument is not operated and detects no AC voltage within three
minutes, it will turn OFF automatically.
Low voltage indicator lamp:
when the cell voltage is less than around
2.6V, the power indicator lamp will flash three times for alarm, and the buz-
zer will sound once, before the instrument turns OFF automatically. The cell
is to be replaced.
Electric torch:
the electric torch lights up when the electric torch switch
③
is pressed, and goes out when the switch is again pressed. If the switch is
turned ON, the electric torch will go out automatically 5 minutes later.
Cell Replacement:
As per the diagram below:
1) Rotate the cell cover
2) Take out the used cell;
3) Put a new cell in as per cell anode and cathode indication
Warning
To avoid electric shock, do not use this instrument before the cell cover is
replaced.
Cell rotation direction
as indicated
User information ex art. 26 D. 49/2014
The symbol labelled on the appliance (Annex IX D. 49/2014) indicates that
the rubbish is subject to “separate collection” and it has been placed on the
Italian market after the December 31, 2010.
The user must therefore assign or (have collected) the rubbish to a
treatment facility according to indications by the local administration, or
hand it over to the reseller in exchange for an equivalent new product. The
separate collection of the rubbish and the subsequent treatment, recycling
and disposal operations encourage the production of appliances made
with recycled materials and reduce negative effects on health and the
environment caused by improper treatment of rubbish.
In the case of very small WEEE (no external dimension more than 25 cm),
the user is eligible to get free of charge assignation to retail shops with sales
areas relating to EEE of at least 400 m².
Made in China
IMPORTED AND DISTRIBUTED BY:
ELCART DISTRIBUTION SPA
Via Michelangelo Buonarroti, 46
20093 COLOGNO MONZESE (MI)
ITALY
www.elcart.com - [email protected]