2
FOR SAFETY REASON A SAFETY DEVICE MUST BE USE WHEN USING THIS REMOTE CONTROL !!!
TERMINALS CONNECTIONS
:
1-2
Antenna, terminal n°2 = RF
15-14
“Start/Stop” push button (n.o. contact)
3-4
Input from intercom 12Vac see <T>
16-14
SS2 push button motor n 2 command
5-6
Closing limit switch (n.c. contact)
see <D>
17-18
Electric - lock 12vac-15w
7-5
Opening limit switch (n.c. contact)
see <D>
18-19
24Vac output (max 3 pairs of photocell)
8-5
‘’open’’ push button (n.o. contact)
or Magnetic Detect
20-21
POWER SUPPLY 230V-50Hz
9-10
‘’close’ ’push button (n.o contact)
22-23
Flashing light 230V -25w
11-10
Photocell n 2 (n.c. contact) or
rubber see logic <H>
24-25
Courtesy light contact ( free voltage)
12-10
Photocell n 1 (n.c. contact)
26-27-28
Motor n 1 (terminal N.27 = com.)
13-14
“Stop” push button (n.c. contact)
29-30-31
Motor n.2 (terminal. N.30 = com.)
LED FUNCTIONS
ON
Normally ON POWER ON BOARD
OK
1 flashing when a radio code is
received and recognized
During programming
1 flashing when a code is
memorized
3
flashing =
error
, the code
received is already in memory
or memory is full
ON, during motor timing
programming
ON, during pause timing
programming
ON, during RESET
Flashing when the RESET has
been execute
M1
ON, when motor n 1 is activated
M1rev
Show the direction of motor n 1
M2rev
Show the direction of motor n 2
M2
ON, when motor n 2 is activated
Elett
ON, when electric-lock is activated
Ped
ON, when SS2 button is pushed
Start
ON, when START button is pushed
Stop
Normally ON it turns OFF when STOP
button is pushed
Fot1
Normally ON it turns OFF when the
photocell n 1 ray is interrupt
Fot2
Normally ON it turns OFF when the
photocell n 2 ray is interrupt
Apre
ON, when OPEN button is pushed
Chiude
ON, when CLOSE button is pushed
Fa1
Normally ON it turns OFF when the
open limit switch is activated
Fc1
Normally ON it turns OFF when the
close limit switch is activated
DIPS SWITCH:
DIP SWITCH ‘’A’’
DIP SWITCH ‘’B’’
A1
Pre-flashing -- L --
B1
Electric-lock -- N --
A2
Walk-way 45° -- M --
B2
Motor phase reverse – G --
A3
Logic 0 -- H --
B3
In ON position = motor delay erased
A4
Logic 1 -- H --
B4
In ON position = slow-down erased
A5
Pause time activated
B5
In ON position = locking for wind – P -
A6
Pause time program – E --
B6
Open gate signal – Q --
A7
M1 timing program – B --
B7
Courtesy lamp = 2 seconds – R --
A8
M2 timing program – B --
B8
Courtesy lamp code program – A4 --
A9
Start code program – A1 --
B9
Soft motor Start – S --
A10
ERASE – I --
B10
Walk-way code program – A7 --
YOU CAN USE WITHOUT PROGRAMMING…… ! -
The control board is supplied with a BASI PROGRAM that give you the following functions :
¾
Motors timing :
20 seconds
–slow-down excluded
¾
Pause time :
30 seconds
¾
Delay time :
5 seconds in closing and 2 seconds in opening
¾
Courtesy lamp time :
3 minutes
¾
Radio code in memory: channel n 1 ASTER with dips
1,3,5,7,9 = ON
= BASIC CODE.