Power up, Testing and Calibration Procedures
Setting up of the VOLT/OCTAVE requires an accurate and stable voltage source. If using
a MIDI-CV device then you should use that to ensure that the VCOs are tuned to your
MIDI device.
1. Disconnect all control inputs (2 x PWM, 2 x LIN FM and 6 x LOG FM) -alternately,
measure each of the inputs and adjust its associated control for a reading of 0.0V
2. Monitor the SAWTOOTH output with a frequency counter or scope
3. Open LK100 (LK150) to disable the `INIT FREQ’ trimpot
4. Adjust P101 (P151) for a frequency of 880Hz
5. Apply 3.0V to one of the LOG FM inputs
6. Adjust P107 (P157) to give a frequency of 7.04kHz
Having set the VOLT/OCTAVE characteristics of the VCO, we can now finalise the setting
up of the VCO.
7. Insert LK100 (LK150)
8. Apply 5.0V (MIDI Note = 60) to one of the LOG FM inputs
9. Adjust `INIT FREQ’ (P100/P150) to give a reading of 261.626Hz.
10.Remove the 5.0V on the LOG FM input
11.Confirm that the output frequency is 8.176Hz
It is worth repeating these steps to ensure that the settings are stable.
This completes the setting up of the VCO. Reconnect all control inputs.
The VCO can now be connected to a 1V/Octave MIDI-CV module and will play the correct
frequency for a given MIDI Note Number as per the MIDI Note Table included with this
documentation (assuming all other control voltages are at 0.0V).
Square Waveform Adjustment
1. The Square output does not need adjustment. Monitor the Square output on J102
(J152) and check that the waveform is centered around 0V.
Triangle Waveform Adjustment
1. Monitor the Triangle output on J102 (J152) and using P103 (P153) adjust the output
until it is centered around 0V.
1. Using P105 (P155) adjust the output until the positive and negative slopes are identical,
2. Using P104 (P154) adjust the output to minimise the glitch at the bottom of the
waveform,
3. Finally, using P106 (P156) adjust the output until is centered around 0V.
Sine Waveform Adjustment
1. Monitor the Sine output on J102 (J152) and using P102 (P152) adjust the output for a
peak-peak output of 10V.