Temperature management frame reports transmitter board temperature trend of last 10 days, with 5
seconds sampling time. Furthermore, it is possible to set and check alarm and warning thresholds (through
the interactive bar and the
Apply
button), and the actual temperature.
Figure 84: Web slot TX form – Power management.
Power management
frame let the user manage transmitter output power, modifying it from factory default
calibration. Power, shown in lower part of the frame and measured in dBm, can be adjusted in a -2 to +2 dB
range from the calibration value. It is possible to mute the transmitter by clicking on the related switch in
the right part of the frame.
Figure 85: Web slot TX form – Frequency.
Frequency frame let the user change the transmitter frequency, depending on the factory limits (shown in
the interactive bar); by default, it is possible to modify the frequency in a +/- 5 MHz range (channel filter is
generally installed).
8.4.4
Slot
–
Rx.
Web section receiver board is composed by 4 frames:
1.
Status
2.
RSSI Graphic
3.
Frequency
4.
Temperature Management
Figure 86: Web slot Rx form – status.
Status frame reports information already shown in homepage (see par.8.2.2).