LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is
necessary to dismount it accurately
clean it with gasoline and spread a bit
of special grease resistant to high
temperatures on it.
The operations must be executed by a
qualified technician.
Normally for G30 gas, fully tighten
the adjustment screw.
Fig. 21
Fig. 22
REGULATING THE BURNER
MINIMUM SETTING
When switching from one type of gas
to another, the minimum flow rate must
also be correct: the flame should not
go out even when passing suddenly
from maximum to minimum flame.
To regulate the flame follow the
instructions below:
✓
Light the burner
✓
Set the cock valve to minimum
On gas valves provided with adjust-
ment screw in the centre of the shaft
(fig. 21):
✓
Using a screwdriver with max.
diameter 3 mm, turn the screw inside
the tap until the correct setting is
obtained.
On gas valves provided with adjust-
ment screw on the valve body (fig. 22):
✓
turn the screw “A” to the correct
setting with a screwdriver.
A