VENTILATION
In general, the appliance should have adequate ventilation for complete
combustion of gas, proper piping of flue and to maintain temperature of
immediate surroundings within safe limits.
Make sure the kitchen is well ventilated for safety purpose. Do not leave
unattended flame in the kitchen. If excessive gas is detected, remove the
regulator from the gas cylinder and request for service immediately.
COMBUSTIBLE SURFACES
Any adjoining wall surface situated within 200mm from the edge of any hob
burner must be a suitable non-combustible and heat resistant material for a
minimum distance of 150mm for the entire length of the hob.
Any construction above the appliance must be at least 770mm above the top of
the burner and no construction shall be done within 450mm above the top of the
burner.
GAS CONNECTION
This appliance is manufactured to match the Universal LPG gas supply. It must
be connected to the gas supply or the cylinder according to the specifications of
the standards and after checking that it is adjusted for the type of gas available.
Once the appliance has been installed, make sure that the gas pipe is neither
squashed nor damaged by moving parts. Before leaving, check all connections
for gas leaks with soap and water.
DO NOT use a naked flame for detecting leaks. Ignite all burners both
individually and separately to ensure correct operation of gas valves, burners
and ignition.