Elation Uni-Pack II User Manual Download Page 4

General Instructions

Warning !!!

Cautions

To prevent fire or shock hazard, do not expose this product to 

rain or moisture. 

In the event of a malfunction(burning smell, etc.), immediately 

stop operation, disconnect the power supply plug, and consult 

authorized service personnel. 

No user serviceable parts inside, always consult authorized 

personnel for repairs.

Take care not to damage the power cord.

Do not make any inflammable liquids, water or metal objects
enter the unit.

This product must be earthed.

Do not dismantle or modify the unit.

Place this unit in a stable location.

Do not use the unit in places subject to excessive humidity, 

vibration or bumps.

Unplug the power plug from the sockets when not using the 

unit for extended period.

Provide occasional ventilation during use.

This product is intended for indoor use only.

To optimize the performance of this product

 

, please read this instruction manual  

carefully to familiarize yourself with the basic operations of this unit.

 

This manual 

contains important information for user, please keep it well for future reference.

2

MENU

DMX

DMX IN

DMX OUT

OUTPUT: 10A MAX.

POWER INPUT : 

AC 120V~60HZ 

10A MAX.

1=Ground
2=Data -
3=Data +

1

2

3

FUSE :

F10A 250V 

5X20MM.

Uni-Pack II

FUSE

F U

S E

PUSH

PUSH

PUSH

1. Overview

3

1. Power Input port:   

  

 

AC 120V~60Hz, 10A Max.  

2. Output:                      

 

10A max.

3. Segment Display:     

 

Shows current activity or function state.

4. 
5. Menu button:              

Use this button to select desired function mode.

6. Up button:                  

 

Each tap will increase the current value once. Pressing and 

                                         holding down this button will increase the value quickly. 

 

9. 

Fuse:    

                       F10A 250V 5x20mm

7. Down button:             

 

Each tap will decrease the current value once. Pressing and

                                         holding down this button will decrease the value quickly.

8. DMX In     

                   

 

3-pin XLR male socket, used to receive DMX data.

DMX Out     

                

 

3-pin XLR female socket, used to send DMX data.                                       

1

2

3

4

5 6 7

8

9

Summary of Contents for Uni-Pack II

Page 1: ...4295 Charter Street Los Angeles CA 90058 www elationlighting com Elation Professional R Uni Pack II User s Manual ...

Page 2: ...iew 3 2 Operation Guide 5 Technical Specifications 10 2 1 DMX Address Mode 5 2 2 Switch Pack Mode 6 2 3 Dimmer Pack Mode 7 Improvement and changes to this manual specifications and design may be made at any time without prior notice ALL RIGHTS RESERVED ...

Page 3: ...he needs of both entertainment and the lighting industry We welcome your comments about our product and services It is both a privilege and a pleasure serving you 3 pin standard DMX IN OUT ports providing dimmer information Serves as a Switch Pack or Dimmer Pack depending upon the current operating mode Allows DMX Addressing Dimmer Preset and Dimmer Limit Power failure memory 4 digits Segment Disp...

Page 4: ...or metal objects enter the unit This product must be earthed Do not dismantle or modify the unit Place this unit in a stable location Do not use the unit in places subject to excessive humidity vibration or bumps Unplug the power plug from the sockets when not using the unit for extended period Provide occasional ventilation during use This product is intended for indoor use only To optimize the p...

Page 5: ... activity or function state 4 5 Menu button Use this button to select desired function mode 6 Up button Each tap will increase the current value once Pressing and holding down this button will increase the value quickly 9 Fuse F10A 250V 5x20mm 7 Down button Each tap will decrease the current value once Pressing and holding down this button will decrease the value quickly 8 DMX In 3 pin XLR male so...

Page 6: ...ed it will be stored into memory automatically 4 MENU MENU General Plug in the appropriate power outlet this unit recovers to the function state of last time automatically by reasons of power failure memory and the Segment Display shows the DMX address of last change If the frequency of power is not stable the Segment Display will show AC 0 wait until the power is stable The product serves as a di...

Page 7: ...tton to enter Switch Pack mode Switch Pack mode consists of Switch On S on and Switch Off S of In the Switch On mode output is turned on and the fixture lights regardless of DMX signal In the Switch Off mode output is turned off and the fixture is controlled by DMX signal When DMX level is less than 40 the fixture goes out when DMX level exceeds 40 the fixture lights 5 MENU MENU MENU s ...

Page 8: ... between Switch On and Switch Off If there is no timely operation on any of the fun ction button the unit will automatically return to the DMX Address function mode 5 Once the Switch Pack is selected press Menu button to return to DMX Address mode 1 Press Menu button to enter next item MENU MENU MENU ...

Page 9: ...mmer Preset mode 4 Tap the Up or Down button to change the value within the range of 10 100 Each tap will change the value once pressing and holding down will change the value quickly The Dimmer Limit level will be stored into memory automatically MENU MENU MENU If there is no timely operation on the button for more than 20 seconds the unit will return to DMX Address function mode again ...

Page 10: ...own button to change the value within the range of 00 100 Each tap will change the value once pressing and holding down will change the value quickly Once the Dimmer Preset is selected it will be stored automatically 5 Press Menu button to return to DMX Address mode 8 ...

Page 11: ...chnical Specifications Power Input AC 120V 60Hz 10 A max Channel Output 10 A max DMX OUT 3 pin XLR female socket DMX IN 3 pin XLR male socket Fuse F10A 250V 5x20mm Dimensions 235x106x64mm Weight 1 6 Kg 9 ...

Page 12: ...rican DJ Group of Companies 4295 Charter Street Los Angeles CA 90058 USA Tel 323 582 3322 Fax 323 582 3311 Web www elationlighting com E mail info elationlighting com Elation Professional R 24 004 1299 Version 1 0 July 2004 ...