©Elation Professionals® - www.elationlighting.com - TVL4000 User Manual Page 7
©Elation Professionals® - www.elationlighting.com - TVL4000 User Manual Page 8
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin XLR
connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures
may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be
used, these adaptors are readily available at most electric stores. The
chart below details a proper cable conversion.
Conductor
5-Pin XLR Male (In)
3-Pin XLR Female (Out)
Pin 1
Pin 5 - Do Not Use
Pin 4 - Do Not Use
Pin 3
Pin 2
Pin 1
Pin 3
Pin 2
Not Used
Not Used
Data True (+ signal)
Data Compliment (- signal)
Ground/Shield
3-Pin XLR to 5-Pin XLR Conversion
TVL4000
Set Up
TVL4000
Control Panel
1 Display:
To show the various menus and the selected functions
2 Indicator LED:
DMX
On
DMX input present
MASTER
On
Master Mode
SLAVE
On
Slave Mode
COLOR TEMP.
Flashing
Max. power consumption of CW/WW
3 Button:
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
4 Color Temperature:
Adjust the color temperature from 3200k to 6500k, 25K as a step.
When the value is between 4825K and 4875K the green LED
indicator will light .It means the power consumption of CW/WW
color the has reached maximum.
5 Dimmer Adjust knob:
Adjust bightness for the unit.
6 DMX output:
For DMX512 link, use 3/5-pin XLR plug cable to link the next unit.
7 DMX input:
For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal
8 Mains input:
Connect to supply mains power