background image

7

 

S A F E T Y   G U I D E L I N E S

 

DO NOT TOUCH

 the fixture housing during operation. Turn OFF the power and allow 

approximately 15 minutes for the fixture to cool down before serving. 

DO NOT

 shake fixture, avoid brute force when installing and/or operating fixture. 

DO NOT

 operate fixture if the power cord is frayed, crimped, damaged and/or if any of the 

power cord connectors are damaged and do not insert into the fixture securely with ease. 

NEVER

 force a power cord connector into the fixture. If the power cord or any of its 

connectors are damaged, replace it immediately with a new one of similar power rating. 

DO NOT 

block any air ventilation slots. 

All fan and air inlets must remain clean and never blocked. 
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling. 
When installing fixture in a suspended environment, always use mounting hardware that is no 
less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable. 
Always disconnect fixture from main power source before performing any type of service 
and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the 
plug by tugging the wire portion of the cord. 
During the initial operation of this fixture, a light smoke or smell may emit from the interior of 
the fixture. This is a normal process and is caused by excess paint in the interior of the 
casing burning off from the heat associated with the lamp and will decrease gradually over 
time.   
Consistent operational breaks will ensure fixture will function properly for many years. 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SATURA PROFILE

Page 1: ...SATURA PROFILE user manual...

Page 2: ...sional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade The Netherlands...

Page 3: ...Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Guidelines 10 Optional Static Gobo Animation Wheel Installation 14 System Menu 18 DMX Channel Functions And Values...

Page 4: ...pport Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Omega Brackets x2 powerCON Cable Safety Cable CUSTOMER SUPPORT Contact ELATION Service for an...

Page 5: ...penses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the p...

Page 6: ...rsonal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURES WARRANT...

Page 7: ...clean and never blocked Allow approx 6 15cm between fixture and other devices or a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no l...

Page 8: ...ized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed ele...

Page 9: ...nction Display 3 MODE ESC Button 4 LEFT Button 5 DOWN Button 6 RIGHT Button 7 ENTER Button 8 UP Button 9 Carrying Handle s 10 RJ45 Input 11 RJ45 Output 12 3pin DMX Output 13 3pin DMX Input 14 5pin DMX...

Page 10: ...rical and construction codes and regulations Before rigging mounting the fixture to any metal truss structure or placing the fixture on any surface a professional equipment installer MUST be consulted...

Page 11: ...ner is completely locked CLAMP INSTALLATION When mounting fixture to truss be sure to secure an appropriately rated professional grade rigging clamp to the included Omega Brackets using an M10 screw f...

Page 12: ...illustrated below S I D E M O U N T I N G I S N O T P E R M I T T E D ART NET CONNECTION When connecting fixture to a network switch to control multiple devices a Gigabit Ethernet Switch that supports...

Page 13: ...st filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ELATION lighting fixtures it is a common issue with lighting fixtures from all manufacturers Al...

Page 14: ...GOBO ANIMATION WHEEL INSTALLATION 1 Place fixture on a flat surface and lock head in an upright position with TILT lock engaged 2 Remove 2x Phillips screws securing top and bottom head panel covers r...

Page 15: ...wssecuring2wireharnessconnectors thencarefullyunplugbothconnectors 4 Remove 2x 2 Philips screws securing the effect module 5 Because the internal lens assembly passes through the effect module tray it...

Page 16: ...ly remove the effect module from fixture 7 Loosen 2x 2 Allen set screws securing the belt gear spindle This will reduce the belt tension on the Static Gobo wheel gear spindle 8 Loosen 2x 2 Allen set s...

Page 17: ...s assembly out and away providing a clear path to remove the Static Gobo wheel 10 If using any of the stock Gobos carefully remove them from the Static Gobo wheel 11 Carefully insert the desired Stati...

Page 18: ...erent functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN bu...

Page 19: ...a DMX ON OFF Address Via DMX No DMX Status Close Shutter Hold Auto Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan D...

Page 20: ...All Motors Reset Pan Tilt Reset Pan Tilt Reset Colors Reset Color Wheel Reset Gobos Reset Gobos Reset Others Reset Other Motors Effect Adjust Test Channel PAN Test function Manual Control PAN XXX Fin...

Page 21: ...tus Close Shutter Hold Auto Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan Degree Select Feedback ON OFF Movement F...

Page 22: ...Modes Basic Mode Extended Mode User Mode A User Defined Channel Assignment User Mode B User Mode C Edit User Mode Edit User Mode A Max Channel XX PAN CH01 Edits User Defined Channel Assignments Edit U...

Page 23: ...DMX value of Channel 1 on the controller to 7 3 Set the DMX value of Channel 2 on the controller to 7 or 8 When set to 7 the DMX address can be set between 1 and 255 When set to 8 the DMX address can...

Page 24: ...and auto test each individual channel function independently from the DMX control board EFFECT ADJUST Manual Control Select and manually test and fine adjust each individual channel function Independe...

Page 25: ...troller Working With Built In Programs A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Ma...

Page 26: ...ms Press ENTER to confirm Select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the...

Page 27: ...250 scenes can be programmed Press ENTER to confirm Press MODE ESC in order to return to the main menu Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes...

Page 28: ...rol of TILT Movement 3 5 5 CYAN COLOR 0 255 0 WHITE 255 100 CYAN 6 CYAN COLOR FINE 0 255 CYAN FINE Adjustment 4 6 7 MAGENTA COLOR 0 255 0 WHITE 255 100 MAGENTA 8 MAGENTA COLOR FINE 0 255 MAGENTA FINE...

Page 29: ...255 Clockwise Gobo Wheel Rotation from SLOW to FAST 10 12 17 ROTATING GOBOS INDEX ROTATION GOBO WHEEL 1 0 127 Gobo Indexing 128 193 Clockwise Gobo Rotation from FAST TO SLOW 194 255 Counterclockwise...

Page 30: ...e SLOW to FAST Static Fixed Gobo 7 224 255 Clockwise Gobo Wheel Rotation from SLOW to FAST DMX VALUES FOR OPTIONAL STATIC GOBO ANIMATION WHEEL KIT See highlighted DMX values below which support the co...

Page 31: ...ism Gobo Macro 16 13 15 21 ROTATING PRISM PRISM INDEX ROTATION 0 127 Prism Indexing 128 189 Clockwise Linear Prism Rotation from FAST to SLOW 190 193 NO Rotation 194 255 Counterclockwise Linear Prism...

Page 32: ...OOM FINE 0 255 ZOOM FINE Adjustment 21 23 33 BLADE 1 0 255 OPEN to CLOSE 34 BLADE 1 FINE 16 BIT 0 255 OPEN to CLOSE FINE Adjustment 22 24 35 BLADE 1 ROTATION 0 255 ROTATION 36 BLADE 1 ROTATION FINE 16...

Page 33: ...otation 30 32 51 BLADE SPEED 0 255 BLADE Speed FAST to SLOW 31 33 52 BLADE MACROS 0 14 OFF 15 29 Blade Macro 1 30 44 Blade Macro 2 45 59 Blade Macro 3 60 74 Blade Macro 4 75 89 Blade Macro 5 90 104 Bl...

Page 34: ...0 84 ALL Motors Reset 85 87 SCAN Motor Reset 88 90 COLOR Motors Reset 91 93 GOBO Motors Reset 94 96 NO FUNCTION 97 99 OTHER Motors Reset 100 119 Internal Program 1 Scene1 8 120 139 Internal Program 2...

Page 35: ...sh repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all the motors and correct the errors If the er...

Page 36: ...r a fixture reset if the magnetic indexing circuit malfunctions sensor failed or magnet is missing or there is a motor failure defective motor or a defective motor IC drive on the main PCB Magenta Col...

Page 37: ...angeable Rotating Indexing Glass Gobos 7 Interchangeable Static Stamped Metal Gobos 4 Interchangeable Static Stamped Metal Gobo Animation Wheel Kit Optional Kit Sold Separately CONTROL CONNECTIONS 3 D...

Page 38: ...sted and found to comply with the limits as per Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This devi...

Page 39: ...P T I O N A L A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp DRCSATPRO Dual Touring Road Case for SATURA PROFILE 501020103010 Optional Static Gobo Animatio...

Page 40: ......

Reviews: