8.   Maintenance and Cleaning the POWER WASH 250B™  

It is absolutely essential that the fixture is kept clean and that dust, dirt, smoke, and fog-
fluid  residues  do  not  built  up  on  or  within  the  fixture.  This  will  reduce  the  risk  of 
premature  lamp  life  failure  and  will  prevent  a  significant  reduction  in  lamp  output. 
Regular cleaning will not only ensure the maximum light-output, but will also allow the 
fixture to function reliable throughout its life.  

A  soft  lint-free  cloth  moistened  with  any  good  glass  cleaning  fluid  is  recom-
mended, under no circumstances should alcohol or solvents be used!

 

The  inside  optical  system  should  be  maintained  only  by  authorized  persons.  Please 
contact  Elation  professionals  for  recommendation  associated  with  internal  cleaning 
procedures.

 

8.1 Safety Regulations 

 

Always disconnect main power before attempting any service related 
issues! 

  Allow ample time for the lamp to cool (at least 20 minutes) before performing 

any cleaning procedures.

 

  Never attempt operation with any of the protective covers removed! 

8.2   Cleaning Frequency (rule-of-thumb) 

 

Section 

Interval 

Procedure 

Outside optic 

Weekly 

soft cloth and glass cleaning fluid 

Color filter 

Monthly 

soft cloth and glass cleaning fluid 

Beam shape 

Monthly 

soft cloth and glass cleaning fluid 

Dimmer/Shutter 

Yearly 

vacuum cleaner, airbrush, etc. 

Fan and air channel 

Monthly 

vacuum cleaner, airbrush, etc. 

Reflector 

Yearly 

soft cloth and glass cleaning fluid 

Lamp 

Never 

 

Moveable parts 

Yearly 

suitable fatty oil 

 

The  above  chart  is  a  recommended  cleaning  schedule  only.  Cleaning  frequency 
depends on the environment in which the fixture operates (I.E. smoke, fog residue, 
dust, dew). In clubs that observe heavier use, we recommend cleaning on a more 
frequent  basis.  Periodic  cleaning  will  ensure  fixture  longevity  and  crisp  lamp 
output.

 

 

Summary of Contents for Power Wash 250B

Page 1: ...User Manual Software Version 1 19 Revised 6 2003...

Page 2: ...Power Wash 250 Elation Professionals Los Angeles Ca wwww ElationLighting com Page 2...

Page 3: ...POWER WASH 250 12 2 3 Connections 13 2 3 1 Power Supply 13 2 3 2 DMX 13 2 4 Fuse 15 3 The Menu Field 16 3 1 DMX Addressing D001 18 3 2 Test Mode TEST 18 3 3 Audio Mode AUDI 18 3 4 Lamp On Off LAMP 19...

Page 4: ...rection of faults EFLD 24 3 11 Error and Information Messages 24 4 Operation 25 DMX Operation 25 Stand Alone Operation 25 Master Slave Operation 26 5 DMX Channel Selection DMX Protocol 27 6 Service an...

Page 5: ...ssories necessary to operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not ret...

Page 6: ...warranty conditions This fixture emits intense UV radiation which is harmful to the eyes and skin The intense luminance of the lamp can cause severe damage to the retina Never operate this fixture wit...

Page 7: ...event personal injury never touch the lamp if you are not absolutely sure it has cooled 5 Never look directly into the lamp beam You risk injury to your retina which may induce blindness 6 Be sure to...

Page 8: ...10 Firmware Connection 11 Microphone Sensitivity 12 DMX Input Jack 13 DMX Output Jack 14 Power On Off Switch 15 Fuse Holder 16 Fan air inlet Max Min DMX IN DMX OUT Software Update 1 G r oun d 2 D ata...

Page 9: ...e by the built in handles Never lift or carrying the fixture by the head or yoke Pulling on or transporting the fixture by the head assembly may severely damage the fixture and will void the fixture w...

Page 10: ...to protect the electronics in the event of sever power fluctuations Always be sure to replace the fuse with an exact match as to the one being replaced unless otherwise told to do so by an authorized...

Page 11: ...ecoration etc Install a safety cable that can hold at least 10 times the weight of the fixture Never use the carrying handles for secondary attachment Refer to regulations BGV C1 former VBG 70 and DIN...

Page 12: ...ng or a wall The plate uses four M6x20 screws 3 2 Securing the POWER WASH 250 Regardless of the rigging option you choose for your POWER WASH 250B always be sure to secure your fixture with a safety c...

Page 13: ...terminals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and ope...

Page 14: ...R s outer casing Grounding the shield could cause a short circuit and erratic behavior 2 7 Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last...

Page 15: ...del or 230V T 3 15A EU model The fuse requirements are clearly printed on the side of the fixture WARNING Always disconnect main power before changing a fuse Always replace with the exact same type fu...

Page 16: ...tivates Sound Active mode fast MSTR Runs fixture as MASTER for Audio Master Slave mode SVPT Runs fixture as SLAVE for Audio Master Slave mode SIZE Room size adjustment NORM BIG MIDL SMAL This adjustme...

Page 17: ...ntrol LOOF Low cooling fan speed lamp off LOHI Low cooling fan speed automatic ADJU CODE xxxx Access the calibration menu with technician code for authorized person only COLO Calibration of the color...

Page 18: ...Down buttons to select adjust the address Lock your new address into by pressing the Enter button After the new address has been successfully stored into the fixture s memory the LED will briefly read...

Page 19: ...t function in the main menu and press the Enter button to engage the reset function RST will readout in the display 3 6 Running time TIME TIME This menu function can read out three different fixture r...

Page 20: ...e SPEC sub menu consists of several sub menus Navigation details of the special functions and their sub menus are as followed 3 10 1 Manual Drive MANU MANU This feature allows you to drive all the uni...

Page 21: ...his function use the Up and Down buttons to toggle between ON and Off Turn this function on to allow DMX switching Press Enter to confirm or Mode to cancel and return to the menu 3 10 4 DMX Readout DM...

Page 22: ...al temperature drops below 95 C 3 10 7 Fan Control FANS FANS By using this function you can choose between 4 types of fan speed operations Use the Up and Down buttons to select the desired function an...

Page 23: ...s and confirm once more with the Enter button or use the Mode button to cancel the operation Function Value Remark COLO 99 99 Color wheel CLRE Adjustments in the internal circuit FACC Must read ON ARE...

Page 24: ...ving switched off lamp too hot The message will appear on the display if the lamp doesn t ignite within 20 seconds The fixture will store this command and automatically ignite the lamp after 5 minutes...

Page 25: ...strobe and all other DMX traits A DMX controller allows you to create unique programs tailored to your individual needs The Power Wash uses 14 DMX channels See page 27 for detailed description of the...

Page 26: ...ct to the low frequiencies of a sound source tapping on the fixture or high pitched sound may not trigger the fixture 4 3Master Slave Operation Sound Active This function will allow you to link up to...

Page 27: ...e slow 76 79 4C 4F 30 0 color 4 Pink slow 80 83 50 53 31 6 color 5 Orange slow 84 87 54 57 33 1 color 6 Italian Blue slow 88 91 58 5B 34 7 color 7 Turquoise slow 92 95 5C 5F 36 3 color 8 Jade slow 96...

Page 28: ...8 29 1C 1D 11 2 4 270 30 31 1E 1F 12 TILT size phase see also PAN 32 63 20 3F 13 25 PAN TILT size phase see also PAN 64 95 40 5F 26 37 PAN TILT inverse size phase see also PAN 96 127 60 7F 38 50 Circl...

Page 29: ...cing with anything other than the specified part can damage your fixture and will void your manufactures warranty Warning If you continue to blow lamps STOP using the fixture Contact customer support...

Page 30: ...r bare hands the oils from your skin may damage the lamp Always replace with the lamp with a lamp that meets the orginal lamp specification failure to do so may damage the unit and will void your manu...

Page 31: ...wait a while until full intensity of the lamp 6 3 2 Using either a DMX controller or the control panel on the unit strike the lamp and focus the light on a flat surface beam open white no gobo no eff...

Page 32: ...inue to blow fuses STOP using the fixture Contact customer support for further instructions you may have to return the unit for servicing Continuing to use the unit may cause serious damage Fuse Repla...

Page 33: ...g procedures 8 1Safety Regulations Always disconnect main power before attempting any service related issues Allow ample time for the lamp to cool at least 20 minutes before performing any cleaning pr...

Page 34: ...technical support Cleaning the Optical System recommended for authorized personal only 1 Always disconnect main power before attempting any service related issues 2 Allow ample time for the lamp to co...

Page 35: ...Power Wash 250 Elation Professionals Los Angeles Ca wwww ElationLighting com Page 35 9 Power Wash Color Wheel Orientation...

Page 36: ...TC 5600k 1x CTC 3300k Mechanically adjustable Beam angel 8 22 Shutter Strobe Dimmer Strobe effect variable in speed 1 10 flashes per second Continuously mechanical dimmer 0 100 Controlling Standard DM...

Page 37: ...to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professionals c...

Page 38: ...ssed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacem...

Page 39: ...Power Wash 250 Elation Professionals Los Angeles Ca wwww ElationLighting com Page 39...

Page 40: ...0 Elation Professionals Los Angeles Ca wwww ElationLighting com Page 40 Elation Professional 4295 Charter Street Los Angeles CA 90058 323 582 3322 323 582 3108 fax www ElationLighting com info Elation...

Reviews: