Control”  submenu.  See  page  21  for  the  menu  breakdown.  Once  in  the 

“Music Control” submenu select “Alone”   

 

 

10.2    Master/Slave Operation (Auto Program or Music Control):

 This function allows 

up to 16 fixtures to be linked together to provide a synchronized light show without 

the  use  of  a  controller.  Only  use  this  when  linking  several  Platinum  Spot  LEDs 

together for use without a controller. Any fixture can act as a “Master or a “Slave.” 

§

  Using  XLR  DMX  cables,  daisy  chain  your  fixtures  together  via  the  XLR 

connectors. Remember the Male XLR connector is the input and the Female 

XLR connector is the output. The first fixture in the chain (master) will use 

the  female  XLR  connector  only  -  The  last  fixture  in  the  chain  will  use  the 

male XLR connector only. For longer cable runs we suggest a terminator at 

the last fixture. 

§

  For  the  unit  functioning  as  the  “Master”  unit  follow  the  same  procedures 

listed in the previous Stand-Alone section.   

§

  For  the  “Slave”  units,  access  the  “Set  To  Slave”  settings  in  the  “Function 

Mode” menu and assign each slave fixture a designation (Slave 1, Slave 2, 

Slave 3

etc). 

 

 

10.3  Universal  DMX  Control:

  This  function  allows  you  to  use  a  universal  DMX-512 

controller such as the Elation® Show Designer 2™ or Elation® Show Designer 3™ to 

control head movement, the color wheel, the shutter (strobe), and all other DMX traits. 

A  DMX  controller  allows  you  to  create  unique  programs  tailored  to  your  individual 

needs. The Platinum Spot LED™ uses 16 (default up to 20) DMX channels. See page 

37  for  detailed  description  of  the  DMX  traits.  To  control  your  fixture  in  DMX  mode, 

follow the set-up procedures on pages 16-19 as well as the set-up specifications that 

are included with your DMX controller. Use the controller’s faders to control the various 

DMX fixture traits. This will allow you to create your own programs. 

§

  Follow the instruction on page 30 to set the DMX address.   

§

  Be  sure  to  use  a  terminator  on  the  last  fixture,  especially  for  longer  cable 

runs (more than a 100 feet). 

§

  For help operating in DMX mode consult the manual that was included with 

your DMX controller. 

Summary of Contents for Platinum Spot LED

Page 1: ...12 15 2010 visage Version 1 0 Platinum Spot LED Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Page 2: ...Platinum Spot LED Elation Professional Los Angeles Ca 2 www ElationLighting com...

Page 3: ...ng and Installation 13 a Mounting Positions 14 b Mounting Points 15 c Securing 15 7 Understanding DMX 16 a DMX Cable Requirements 16 b DMX Terminator 17 c 3 Pin to 5 Pin Conversion 18 d DMX Addressing...

Page 4: ...to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please conta...

Page 5: ...You may obtain a R A number by contacting customer support at 323 582 3322 Important Damages caused by the disregard of the instructions in this user manual are not subject to warranty Epileptic Warn...

Page 6: ...e the power cord by the plug Never pull out the plug by tugging the wire portion of the cord This fixture is designed for use indoors Use of this fixture outdoors will void the manufactures warranty P...

Page 7: ...performing any service related issues 4 Never look directly into the lamp beam You risk injury to your retina which may induce blindness 5 For safe operation follow the Installation guide described in...

Page 8: ...be Prism and prism rotation with 16 prism macros Frost Filter for Soft and Hard Edge Spot Bright CBM 360 LED Light Source 100 000 Hours Rated LED Life Source Dimmer intensity from 0 100 Electronic Pow...

Page 9: ...dust The minimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft Always install the fixture with an appropriate safety cable When installing the fixtur...

Page 10: ...om 5 FIXTURE OVERVIEW 1 Main Output Lens 2 Display 3 DC Switch 4 Microphone 5 Left Button 6 Down Button 7 Right Button 8 Mode Esc Button 9 Up Button 10 Enter Button 11 Handle 12 3 Pin DMX in 13 3 Pin...

Page 11: ...utton is used to toggle through the menu display 6 Down Button The down button is used to toggle down or back through the menu functions and settings 7 Right Button This button is used to toggle throu...

Page 12: ...is used to send an incoming DMX signal to the next fixture in the DMX chain via a female 3 pin XLR jack 16 Power Switch Controls main power to the fixture 17 Fuse Holder Assembly This assembly houses...

Page 13: ...device when mounting removing or servicing the fixture Caution When install the fixture be sure there is no highly inflammable material within a distance of 1 5 feet Mounting The Platinum Spot LED is...

Page 14: ...lation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation c...

Page 15: ...screw fitted through the center hole of the omega bracket As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging po...

Page 16: ...nected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the midd...

Page 17: ...atic behavior DMX 512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head Please refer...

Page 18: ...the line Using a line terminator Elation part DMX T PACK will decrease the possibilities of erratic behavior 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for DATA transmission...

Page 19: ...X channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the Platinum Spot LED which is a 16 channel fixture default you should s...

Page 20: ...fly readout OK to confirm a new setting has been made and locked into memory You may exit the main menu at any time without making any adjustments by tapping the MODE ESC button MODE ESC Button To acc...

Page 21: ...a DMX No DMX Status Pan Reverse Tilt Reverse Pan Degree Feedback Movement Speed Mic Sensitivity Hibernation ON OFF Close Hold Auto Music ON OFF ON OFF 630 540 ON OFF Speed 1 4 0 99 OFF 1 99M 15M Add v...

Page 22: ...ogram 3 Select programs to be run Edit Program Program 1 Program 10 Program Test Step 01 SCxxx Step 64 SCxxx Testing program Program in loop Save and exit Edit Scenes Edit Scene 001 Edit Scene 250 Pan...

Page 23: ...Master Slave mode Each slave setting will have a different function for a dynamic lightshow without a controller 8 1 4 Auto Program This function allows the internal programs to run in either stand a...

Page 24: ...word Use this function to enter the Clear Last Run password Password is 038 Clear Last Run This function will allow the Last Run Hours function be cleared and reset 8 2 2 Temperature Info This functio...

Page 25: ...nd return to the main menu This function is OFF by default Tilt Reverse This function allows you to invert all tilt movements Use the Up and Down buttons to turn this function On or Off Press the Ente...

Page 26: ...Fans Control This function is used to change the functionality of the internal cooling fans The available selections are 1 AUTO The fans will automatically switch between low and high speeds depending...

Page 27: ...ion returns a motor to the Home position There are several reset functions available on this fixture The list below details the functionality of each available selection Reset All This function will r...

Page 28: ...Mode Set 8 6 1 User mode This function allows the user to create user defined channel orders allowing the fixture to match the channel order of other fixtures on the market for easier operation A tot...

Page 29: ...e user defined built in programs that are accessed in the previous step 8 7 4 Rec Controller The Platinum Spot LED features an integrated DMX recorder Pre programmed scenes can be transmitted to the f...

Page 30: ...the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX addressing RDMX Address Vi...

Page 31: ...o a value of 7 and use channel 3 to set your address to 57 by selecting a channel value of 57 Example 2 If you want to set the starting address to 420 set channel 1 to a value of 7 channel 2 to 8 and...

Page 32: ...o get a synchronized light show without the need of an external controller The fixtures will react to sound chasing to a synchronized light show Set To Slave This function will set the fixture to slav...

Page 33: ...in the previous Stand Alone section For the Slave units access the Set To Slave settings in the Function Mode menu and assign each slave fixture a designation Slave 1 Slave 2 Slave 3 etc 10 3 Universa...

Page 34: ...red in a Program If you wish to build a static scene a scene consisting of no movement for a logo or gobo projection the scene must be stored inside a program To build a scene follow the instructions...

Page 35: ...er adjust the dimmer intensity Scene Time set the hold time for the scene Input By Out this function will store a scene from an external DMX console See the next section for scene editing via an exter...

Page 36: ...a scene to the program Tapping the Enter button will automatically lock the selected scene into the programs memory Repeat the process until all the desired scenes have been added to the program Each...

Page 37: ...he fixture will use 20 DMX channels DMX channel function and values DMX channel functions and values 20 DMX channels Mode Channel Value Function St Ba Ex PAN Movement 8bit 1 1 1 0 255 Pan Movement By...

Page 38: ...9 Gobo 2 shake slow to fast 120 139 Gobo 3 shake slow to fast 140 159 Gobo 4 shake slow to fast 160 179 Gobo 5 shake slow to fast 180 199 Gobo 6 shake slow to fast 200 119 Gobo 7 shake slow to fast 6...

Page 39: ...cro 3 152 159 Macro 4 160 167 Macro 5 168 175 Macro 6 176 183 Macro 7 184 191 Macro 8 192 199 Macro 9 200 207 Macro 10 208 215 Macro 11 216 223 Macro 12 224 231 Macro 13 232 239 Macro 14 240 247 Macro...

Page 40: ...Blackout with any motor movement 15 13 19 246 255 No function Lamp on off reset internal programs 0 19 Color Gobo change normal 20 29 Color change to any position 30 39 Color Gobo change to any positi...

Page 41: ...third attempt all the errors have not been corrected the fixture will make the following determinations 1 3 or more errors The fixture cannot function properly with three or more errors therefore the...

Page 42: ...defective motor IC drive on the main PCB Rotating gobo indexing error The gobo is not located in the default position after start up or after a reset command This message will appear after a fixture r...

Page 43: ...error This message will appear after the reset of the fixture and if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driver circuit...

Page 44: ...parts and motors should not show any traces of serious wear and should rotate freely 4 Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong...

Page 45: ...Platinum Spot LED Elation Professional Los Angeles Ca 45 www ElationLighting com 15 PHOTOMETRIC DATA...

Page 46: ...Platinum Spot LED Elation Professional Los Angeles Ca 46 www ElationLighting com 16 GOBOS...

Page 47: ...Platinum Spot LED Elation Professional Los Angeles Ca 47 www ElationLighting com 17 DIMENSIONAL DRAWINGS...

Page 48: ...Platinum Spot LED Elation Professional Los Angeles Ca 48 www ElationLighting com 18 CIRCUIT SCHEMATICS...

Page 49: ...d with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number...

Page 50: ...uding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or...

Page 51: ...lass Gobos Gobo wheel 2 7 fixed gobos plus open Gobo outside diameter 26 9 mm image size 22 mm Gobo thickness max glass 1 mm steel 0 15 mm Prism Rotating 3 face prism rotating and variable in speed Sh...

Page 52: ...Length of the base 13 75 35cm Without Handles Width of Head 18 5 47cm Height head vertical 25 63 5cm Weight net 16Kgs 35 Lbs Operating Noise Levels Base level 46 8dB Mode Auto 1m 55 9 dB Mode High 1m...

Page 53: ...Platinum Spot LED Elation Professional Los Angeles Ca 53 www ElationLighting com...

Page 54: ...Platinum Spot LED Elation Professional Los Angeles Ca 54 www ElationLighting com...

Page 55: ...Platinum Spot LED Elation Professional Los Angeles Ca 55 www ElationLighting com...