w w w . e l a t i o n l i g h t i n g . c o m
35
PLATINUM PROFILE LED™ User Manual Ver 1
ELATION© PLATINUM PROFILE LED™
E R R O R C O D E S
Specifications and features are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
PAN Er
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or a defective motor IC drive on the main PCB). This error
may also be displayed if the head/yoke was blocked during a reset function.
TILT Er
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB). This error may also
be displayed if the head was blocked during a reset function.
Color Wheel 1 Er
The Color Wheel #1 is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive
on main PCB).
Color Wheel 2 Er
The Color Wheel #2 is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive
on main PCB).
Gobo Wheel 1 Er
The Gobo Wheel #1 movement is not located in the default position after the
reset. This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper
motor failure (defective motor or defective motor IC drive on main PCB).
Gobo Rot.1 Er
The Gobo Rot.#1 movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel’s
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive
on main PCB).
Gobo Wheel 2 Er
The Gobo Wheel #2 movement is not located in the default position after the
reset. This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper
motor failure (defective motor or defective motor IC drive on main PCB).
Focus Er
The Focus movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive
on main PCB).