Replacing the lamp 

 

DANGER TO LIFE!

 Only install the lamp with the device switched off! Unplug from mains before! 

 

CAUTION!

 The lamp has to be replaced when it is damaged or thermally deformed due to the heat! 

The lens must be replaced if it is visibly damaged and therefore operating with reduced efficiency. 

 Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes). 

 During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp 

manufacturer’s notes! 

 Do not install lamps with a higher wattage! Lamps with a 

higher wattage generate temperatures the device was not 

designed for. Damages caused by non-observance are not 

subject to warranty. 

 For the installation, you need one HMI lamp with up to max. 

575W. 

 

Procedure:

 

Step 1: Open the Service Lid on the top of the device   

by unscrew the one screw. 

Step 2: Loose the two screws at the two ends of the lamp. 

Step 3: Remove the old lamp. 

Step 4: Install a same type lamp into the lamp-socket,         

fasten the two screws by hands. 

Step 5: Close the Service Lid and screw the screw. 

 

Installing 

 The installation of the device has to be built and constructed in a way that it can hold 10 times the 

weight for 1 hour without any harming deformation. 

 The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch 

net. This secondary safety attachment must be constructed in a way that 

no part of the installation can fall down if the main attachment fails. 

 

Caution:

 Devices may cause severe injuries when crashing down! If you 

have doubts concerning the safety of a possible installation, do NOT 

install the device! 

 

DANGER OF FIRE! 

When installing the device, make sure there is no 

highly inflammable material (decoration articles, etc.) within a distance of 

min. 0.5 M. 

 Mount the device with the mounting-bracket to your standing system. The 

hole in the mounting bracket has a diameter of 13 mm. 

 Adjust the desired inclination-angle via the mounting-bracket and fix 

  the fixation screws. 

 

DANGER TO LIFE!

 Before taking into operation for the first time, the 

installation has to be approved by an expert or by qualified 

ENGINEERS/TECHNICIANS only! 

 

Connection with the mains 

 

DANGER TO LIFE!

 The electric connection must only be carried out by a qualified electrician! 

 In order to connect the device to the mains, you have to install a power-plug. 

 The occupation of the connection-cables is as follows: 

 

Cable   

Pin   

International 

Brown 

Live 

Blue 

Neutral N 

Yellow/Green  Earth 

 

 

 The earth has to be connected! 

 Connect the device to the mains with the power-plug. 

 If the device will be directly connected with the local power supply network, a disconnection switch with 

a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation. 

 Lighting effects cannot be connected to      dimming-packs. 

 

DANGER TO LIFE!

 Before taking into operation for the 

  first time, the installation has to be approved by an 

expert!

 

 

 

OPERATION: 

 After you connected the fixture to the mains, 

the lamp will be on. Please see the right figure, 

you can adjust the 1, 2, 3, 4 four places to 

center the lamp in the reflector, and you 

adjust beam field by pulling and pushing the 

handle screw through the track on the top of 

the device. 

 

CLEANING AND MAINTENANCE 

 The following points have to be considered   

during the inspection: 

1)All screws used for installing the devices or 

parts of the device have to be tightly connected 

and must not be corroded. 

2)There must not be any deformations on housings, 

fixations and installation spots(ceiling, suspension. 

trussing). 

3)The electric power supply cables must not show any damages, material 

fatigue (e.g. porous cables) or sediments. Further instructions 

depending on the installation spot and usage have to be adhered 

by a skilled installer and any safety problems have to be 

removed. 

 

DANGER TO LIFE!

 Disconnect from mains before   

starting maintenance operation! 

 We recommend a frequent cleaning of the device.   

Please use a moist, lint-free cloth. Never use alcohol or   

solvents! 

 The interior of the device should be cleaned at least   

annually using a vacuum-cleaner or an air-jet. 

 There are no serviceable parts inside the device except for the lamp. Maintenance and service 

operations are only to be carried out by authorized dealers. 

 Please refer to the instructions under “Replacing the lamp”. 

 Should you need any spare parts, please use genuine parts. 

 If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers 

only in order to avoid hazards. 

 Should you have further questions, please contact your dealer. 

 

TECHNICAL SPECIFICATIONS 

 

 

 

 

 

                                 

                                                                                                                                                            Made in China                                                                     

Power supply: 

Max. 230/240V/AC, 50Hz 

Power consumption, 

Max. 600W 

Dimensions (L x W x H); 

890x330x520mm 

Weight; 

23 kg 

Fitting lamp 

HMI 575W Lamp   

Maximum ambient temperature t

a

:  25°C 

Maximum housing temperature t

S

:  130°C 

Minimum distance: 

2m 

Fuse: 

6.3A 250V 

Ballast

Cooling Fan

HMI 575 Lamp

Service Lid