Elation FS-150SCI User Instructions Download Page 6

©

Elation Professionals

®

 - www.elationlighting.com - FS-150SCI™ Instructions Page 12

Listed below are a few common problems the user may encoun-

ter, followed by possible solutions.

No light from the unit;

1.  Check if the ‘Power On’ (red) LED is lit and the fan is running.  

     If not, there is no main supply.  

2.  Check the fuse. 

3.  Check if lamp is lit.  The user should be able to see some light 

     escape through the fan. If power is present but the lamp is not 

     lit, lamp may need to be replaced. 

4.  Be sure the main power is pushed in all the way on the rear 

     of the unit as well as the power outlet

5.  Be sure the power switch is in the on position.

The fan is on but there is not light output;

1.  Be sure to give lamp ample time to warm up.

2.  Open the socket assemble and be sure the lamp is properly 

     installed.

 

Unit not responding to DMX;

1.  Be sure your dip switch settings are correct. 

2.  Check that the DMX cables are connected properly and are 

     wired  correctly  (pin  3  is ‘hot’; on  some  other  DMX  devices 

     pin 2 may be ‘hot’). Also, check that all cables are connected 

     to the right connectors; it does matter which way the inputs 

     and outputs are connected.

3.  If  DMX  connectors  are  fairly  short,  ordinary  microphone 

     cables  may  be  used. For  longer  runs,  this  may  cause  data 

     transmission  problems  (which  will  show  up  as  random  or 

     incorrect  movements)  for  best  result,  use  proper  balanced 

     data transmission cable.

If problems are not resolved; 

Contact your Elation Professionals

®

 

dealer for service.

  FS-150SCI™ Trouble Shooting

Caution! Never open the unit while in use.  Always disconnect the main 

power  before  attempting  to  replace  the  lamp. Remember  to  always 

replace  with  the  exact  same  type  lamp  and  fuse,  unless  otherwise 

instructed by an authorized Elation

®

 service technician.

1.   Be sure to follow the proper procedures when handling discharge

      lamps.

2.  Remove the thumb screw on the rear of the unit that secures the 

      control unit to the chassis.

3.   Pull down the control unit to expose the lamp socket assembly.

4.   Unscrew the three screws that hold the lamp socket assembly in 

      place and remove the socket assembly.

5.   Remove and replace the lamp.

6.   Reassemble.

  FS-150SCI™ Cleaning

  FS-150SCI™ Lamp Replacement

Due to fog residue, smoke, and dust, cleaning the internal and external 

optical lenses must be carried out periodically to optimize light output. 

 

1.   Use normal glass cleaner and a soft cloth to wipe down the outside 

      casing.

2.   Use a brush to wipe down the fan grill and remove as much built up

      as possible.

3.   Clean  the  external  optics  with  glass  cleaner  and  a  soft  cloth 

      every 20 days.

4.   Clean  the  internal  optics  with  glass  cleaner  and  a  soft  cloth 

      every 30-60 days.

5.   Always  be  sure  to  dry  all  parts  completely  before  plugging  the 

      unit in.

Cleaning frequency depends on the environment in which the fixture 

operates (i.e. smoke, fog residue, dust, dew).

 FS-150SCI™ Warranty Card

The  FS-150SCI™ carries a two year limited warranty. We recommend 

you  fill  out  the  enclosed  warranty  card  to  validate  your  purchase. All 

returned service items whether under warranty or not, must be freight 

pre-paid and accompany a R.A. Number. If the unit is under warranty, 

you must provide a proof of purchase invoice.  A R.A. Number may be 

obtained by contacting Elation

®

 customer support.

©

Elation Professionals

®

  -  www.elationlighting.com  - FS-150SCI™ Instruction Manual Page 11

Summary of Contents for FS-150SCI

Page 1: ...re no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures war ranty In the unlikely event your unit may require service please contact your...

Page 2: ...d interference to connect a DMX 120 Ohm 1 4 W b and PIN 3 DMX 1 2 3 1 2 3 DMX DMX COMMON DMX512 OUT 3 PIN XLR Figure 3 FS 150SCI Set Up 1 Ground 1 Ground XLR Male Socket XLR Pin Configuration 3 Hot 2...

Page 3: ...sing DMX CHANNEL 1 2 3 5 4 7 9 8 6 ON 1 4 16 64 256 2 8 32 128 1 IRIS OPEN Holding this button will open the IRIS 2 IRIS CLOSE Holding this button down will close the IRIS 3 ON Pressing this button wi...

Page 4: ...d to the male XLR in jack located on the lower front end of the unit B Locate the dip switches on the front of the unit Set dip switch one to the on position and be sure dip switches 2 9 are all set t...

Page 5: ...rrect dip switch settings 1 2 4 3 5 6 MASTER HEAD 1 7 8 9 ON 1 2 4 3 5 6 HEAD 2 7 8 9 ON 1 2 4 3 5 6 HEAD 7 7 8 9 ON 1 2 4 3 5 6 HEAD 8 7 8 9 ON 1 2 4 3 5 6 HEAD 3 7 8 9 ON 1 2 4 3 5 6 HEAD 4 7 8 9 ON...

Page 6: ...n power before attempting to replace the lamp Remember to always replace with the exact same type lamp and fuse unless otherwise instructed by an authorized Elation service technician 1 Be sure to fol...

Page 7: ...act and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professionals will replace defective parts at its expense and will absorb all...

Page 8: ...Specifications Model FS 150SCI Lamp SC150 120v 150w Discharge Voltage 110v 120v 50Hz 60Hz Dimensions 10 H x 11 W x 17 L Colors 7 plus White Weight 27 Lbs Fuse 5 Amp Improvements and changes in specifi...

Reviews: