Master-Slave Operation:

 

This function will allows you to link units together to run in a Master-Slave 

mode. In Master-Slave operation one unit will act as the controlling unit 

and the others will react to the controlling units built-in programs. Any 

unit can act as a Master or as a Slave however, only one unit can be pro-

grammed to act as the “Master.” 
Master-Slave Connections and Settings:

1.   Daisy chain your units via the XLR connector on the rear of the unit.  

  Use standard XLR data cables to link your units together. Remem- 

  ber that the Male XLR connector is the input and the Female XLR  

  connector is the ouput. The first unit in the chain (master) will use  

  the female XLR connector only. The last unit in the chain will use the 

  male XLR connector only. 

2.   Set the “Master” unit to your desired mode or operation.  

3.   For the “Slave” unit(s), set the display to any DMX channel mode.  

4.   Connect the “Slave” unit or units and they will automatically start to 

     follow the “Master.”

 ELED QA Strip                         Master-Slave Configuration

mode, 54 Channel mode, and a 72 Channel mode. See pages 11-16 for 

each modes’ DMX traits.

1.  This function will allow you to control each individual fixture’s traits  

  with a standard DMX 512 controller such as the Elation®  Show   

  Designer™ or the Elation® DMX Operator™.

2.  To run your fixture in DMX mode, plug in the fixture via the XLR con-

  nections to any standard DMX controller. Select your desired DMX  

  mode, and then press the UP or DOWN buttons to adjust the DMX 

 address.

3.   DMX Channel Modes are as follows:

  •  To run the 1 Channel Mode, press the MODE button until “1    

  Channel DMX” is displayed. This is the DMX addressing for the 1  

  Channel Mode.

  •  To run the 2 Channel Mode, press the MODE button until “2    

  Channel DMX” is displayed. This is the DMX addressing for the 2  

  Channel Mode.

  •   To run the 4 Channel Mode, press the MODE button until “4   

  Channel DMX” is displayed. This is the DMX addressing for the 4  

  Channel Mode.

  •   To run the 5 Channel Mode, press the MODE button until “5    

  Channel DMX” is displayed. This is the DMX addressing for the 5  

  Channel Mode.

  •   To run the 7 Channel Mode, press the MODE button until “7    

  Channel DMX” is displayed. This is the DMX addressing for the 7  

  Channel Mode.

  •   To run the 8 Channel Mode, press the MODE button until “8    

  Channel DMX” is displayed. This is the DMX addressing for the 8  

  Channel Mode.

  •   To run the 36 Channel Mode, press the MODE button until “36  

  Channel DMX” is displayed. This is the DMX addressing for the 36  

  Channel Mode.

  •   To run the 54 Channel Mode, press the MODE button until “54  

  Channel DMX” is displayed. This is the DMX addressing for the 54  

  Channel Mode.

  •   To run the 72 Channel Mode, press the MODE button until “72  

  Channel DMX” is displayed. This is the DMX addressing for the 72  

  Channel Mode.

4.   Please see pages 11-16 for DMX values and traits.

 ELED QA Strip                                 Operating Instructions

Summary of Contents for ELED QA Strip

Page 1: ...ELED QA Strip is a powerful DMX intelligent 4 in 1 RGBA Red Green Blue Amber LED strip This unit can has 4 operat ing modes Macro mode Program mode RGBA mode and DMX con trolled This unit can be used...

Page 2: ...cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate norm...

Page 3: ...use stan dard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end...

Page 4: ...tion Professional www elationlighting com ELED QA Strip Instruction Manual Page 7 speed by following the next set of instructions The direction of cer tain programs can also be changed under Direction...

Page 5: ...the Elation Show Designer or the Elation DMX Operator 2 To run your fixture in DMX mode plug in the fixture via the XLR con nections to any standard DMX controller Select your desired DMX mode and the...

Page 6: ...0 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 0 255 COLOR MACROS PLEASE SEE COLOR MACRO CHART ON PAGE 17 6 0 15 NOTHING 16 255 STROBING SPEED CONTROL 7 MASTER DIMMER 0 255 0 100 Channel 1 2 3 4 will not...

Page 7: ...7 MODE 0 127 OFF 128 159 AUTO MIX 160 191 3 COLOR JUMP 192 223 7 COLOR JUMP 224 255 SOUND ACTIVE 8 MASTER DIMMER 0 255 0 100 ELED QA Strip 36 Channel Mode Channel Value Function 1 RED LED 1 2 0 255 0...

Page 8: ...EN LED 17 0 255 0 100 67 BLUE LED 17 0 255 0 100 68 AMBER LED 17 0 255 0 100 69 RED LED 18 0 255 0 100 70 GREEN LED 18 0 255 0 100 71 BLUE LED 18 0 255 0 100 72 AMBER LED 18 0 255 0 100 ELED QA Strip...

Page 9: ...55 71 77 71 Macro mode44 173 176 147 164 212 0 Macro mode13 49 52 255 83 134 83 Macro mode45 177 180 88 2 163 0 Macro mode14 53 56 255 93 182 93 Macro mode46 181 184 0 38 86 0 Macro mode15 57 60 255 9...

Page 10: ...ts without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with prod...

Page 11: ...n Professional www elationlighting com ELED QA Strip Instruction Manual Page 21 Elation Professional www elationlighting com ELED QA Strip Instruction Manual Page 22 ELED QA Strip Notes ELED QA Strip...

Page 12: ...e 72 Channel Mode Warranty 2 Year 730 days Elation Professionals 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 3322 Fax 323 832 9142 Web www elationlighting com E mail info elationlighting c...

Reviews: