Elation Elar Quad Par User Manual Download Page 5

 
 

w w w . e l a t i o n l i g h t i n g . c o m    

 

                                                                                                                                                                                        5

                                                               

ELAR   QUAD   PAR

™   

User   Manual   2.0

 

BOX CONTENTS 

  (1) IP68 Rated Power Cable

 

  (1) 3-Pin XLR Cable 

  (1) Safety Cable

 

  Manual & Warranty Card

 

M A N U A L   U P D A T E S  

Please check 

www.elationlighting.com

 

for the latest revision/update of this manual. 

CUSTOMER SUPPORT 

Elation  Professional

®

  provides  a  customer  support  line,  to  provide  set  up  help  and  to 

answer  any  question  should  you  encounter  problems  during  your  set  up  or  initial 

operation.  You  may  also  visit  us  on  the  web  at 

www.elationlighting.com

  for  any 

comments  or  suggestions.  For  service  related  issue  please  contact  Elation 

Professional®. Service Hours are Monday through Friday 8:00 a.m. to 5:00 p.m. PST. 

Voice: 323-582-3322

   

 

 

 

Fax: 323-832-9142

 

E-mail: 

[email protected]

 

Forum: 

www.ElationLighting.com/forum

 

 

WARRANTY REGISTRATION

 

The 

ELAR  QUAD  PAR

 carries a two-year (730 days) limited warranty. Please fill out 

the enclosed warranty card to validate your purchase. All returned service items whether 

under  warranty  or  not,  must  be  freight  pre-paid  and  accompany  a  return  authorization 

(R.A.)  number.  The  R.A.  number  must  be  clearly  written  on  the  outside  of  the  return 

package.  A  brief  description  of  the  problem  as  well  as  the  R.A.  number  must  also  be 

written  down  on  a  piece  of  paper  and  included  in  the  shipping  container.  If  the  unit  is 

under  warranty,  you  must  provide  a  copy  of  your  proof  of  purchase  invoice.  Items 

returned  without  a  R.A.  number  clearly  marked  on  the  outside  of  the  package  will  be 

refused  and  returned  at  customer’s  expense.  You  may  obtain  a  R.A.  number  by 

contacting customer support at 323-582-3322. 

I M P O R T A N T   N O T I C E !  

There  are  no  user  serviceable  parts  inside  this  unit.  Do  not  attempt  any  repairs 
yourself; doing so will void your manufactures warranty. Damages resulting from 
modifications  to  this  fixture  and/or  the  disregard  of  safety  and  general  user 
instructions  found  in  this  user  manual  void  the  manufactures  warranty  and  are 
not subject to any warranty claims and/or repairs. 

 

 

 

 

 

Summary of Contents for Elar Quad Par

Page 1: ...ELAR QUAD PAR user manual 2 0 E L A TI ON ELAR QUAD PAR user manual 2 0...

Page 2: ...wledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all lia...

Page 3: ...0 C O N T E N T S General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Features 9 Fixture Overview 10 Installation 11 Understanding DMX 14 Fixture Menu 18 DMX Channel Values 27...

Page 4: ...of protection The first digit Foreign Bodies Protection indicates the extent of protection against particles entering the fixture and the second digit Water Protection indicates the extent of protecti...

Page 5: ...the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number mu...

Page 6: ...t forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional w...

Page 7: ...manufactures warranty and increase the risk of damage and or personal injury Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindn...

Page 8: ...llation and or operation without proper knowledge of how to do so Do not permit operation by persons who are not qualified for operating this type of theatrical fixture Most damages are the result of...

Page 9: ...Aluminium Body USITT DMX 512 with 4 5 6 8 and 36 DMX Channel Operation Strobe Effect with 1 18 flashes per second 0 100 Dimming and Blackout for all LEDs Excellent Color Mixing and Chase Effect Singl...

Page 10: ...exit the current command 6 UP Button Used to toggle forward through the menu functions and settings 7 DOWN Button Used to toggle down or back through the menu functions and settings 8 ENTER Button Us...

Page 11: ...ersonnel might reach the fixture Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 160 lbs 73 kgs Fixture i...

Page 12: ...ection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operatio...

Page 13: ...al 3 Safety Cable included INSTALLATION VIA MOUNTING BRACKET Attach clamp to center 13 hole on the Mounting Bracket Pull the included Safety Cable underneath the Mounting Bracket and over the trussing...

Page 14: ...ne with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed a...

Page 15: ...l linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out data connections never split or Y your DMX c...

Page 16: ...n XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor m...

Page 17: ...o the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the ca...

Page 18: ...and make all necessary adjustments to the ELAR QUAD PAR During normal operation pressing the MENU button once will access the fixture s main menu Once in the main menu you can navigate through the dif...

Page 19: ...r 3 seconds to activate SET CHAN 4CH 5CH 6CH 8CH 36CH DMX Channel Mode FAIL OFF HOLD AUTO Status while there is no DMX DFSE ON OFF Default setting POHO ON OFF Power on to preserve the MANL settings VE...

Page 20: ...function you can adjust the desired DMX address via the Control Board 1 Select VALU by pressing UP or DOWN buttons 2 Press ENTER adjust the DMX address by pressing UP or DOWN button 3 Press ENTER to c...

Page 21: ...adjust the starting address between 1 and 255 When set to 8 you can adjust the starting address between 256 and 510 Set the DMX value of channel 3 to the desired starting address If you want to set t...

Page 22: ...ure the display 1 Select FLIP by pressing UP or DOWN buttons 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON to enable this function or press DOWN to select OFF 4 Press ENTER to conf...

Page 23: ...OFF HOLD or AUTO the default is HOLD 4 Press ENTER to confirm or press MENU to return to the main menu Restore Factory Settings With this function you can restore the factory settings of the device Al...

Page 24: ...or DOWN button to select TIME 3 Press MODE ESC to enter the main menu display flashing 4 Press UP or DOWN button to select TIME Fixture Running Time With this function you can display the running time...

Page 25: ...splay shows S XX X stands for the total amount of steps you want to save so you can call up to 48 scenes in RUN For example if the XX is 05 it means that RUN will run the first 5 scenes you saved in E...

Page 26: ...ngs for the scene you are editing the display will change to the next scene automatically 10 Repeat step 3 8 to edit other scenes you can edit and save a maximum of 48 scenes 11 Press MENU to exit The...

Page 27: ...w w w e l a t i o n l i g h t i n g c o m 27 ELAR QUAD PAR User Manual 2 0 D M X C H A N N E L F U N C T I O N S A N D V A L U E S...

Page 28: ...w w w e l a t i o n l i g h t i n g c o m 28 ELAR QUAD PAR User Manual 2 0...

Page 29: ...w w w e l a t i o n l i g h t i n g c o m 29 ELAR QUAD PAR User Manual 2 0 L E D N U M B E R S 1 9 3 4 5 2 8 7 6...

Page 30: ...fer to the following points during routine inspections A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and preve...

Page 31: ...ay vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage Patterns On Off Cycling Control and Dimming OPTICAL 11 Beam Angle 20 Field Angle COLOR MI...

Page 32: ...ED LEDs 8810 2326 986 GREEN LEDs 12520 2989 1374 BLUE LEDs 2670 690 284 WHITE LEDs 17980 3683 1691 FULL ON LEDs 36690 9010 3849 PHOTOMETRIC DATA DIMENSIONAL DRAWINGS millimeters Please Note Specificat...

Page 33: ...n l i g h t i n g c o m 33 ELAR QUAD PAR User Manual 2 0 CIRCUIT SCHEMATIC Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any pri...

Page 34: ......

Reviews: