background image

 
 
 

ELAR PAR 72 UV

 

©Elation Professional, Los Angeles Ca. 

25 

 

www.ElationLighting.com

   

displayed as “11XX,” it stands for Channel 11 of the editing scene, the DMX value 

is “XX.” 

6.  Adjust the DMX value by tapping the UP button, until you get the expected effect 

for this channel. 

7.  Press ENTER to enter the editing of the other channels of the scene. 

8.  Repeat steps 5-8, until you finish setting all the DMX values for all the channels 

of this scene, each scene can have 16 channels maximum. 

9.  Once all the channels are completed, the display will begin to flash “TIME,” this 

indicates the time needed to run this scene. 

10. Press ENTER to edit the time needed, the display shows 

TXXX

XXX

 

represents the time needed to run this scene. For example, 

T002

 means 

scene 1 needs 0.4 seconds to run, 

T-15

  means this scene needs 3.0 seconds 

to run. Note: “XX

  is always 0.2 seconds not one second. 

11. Adjust the time needed by tapping the UP button. 

12. Press ENTER to save the settings for the scene you are editing, the display will 

change to the next scene automatically. 

13. Repeat steps 3-12 to edit other scenes, you can edit and save 48 scenes 

maximum. 

14. Press MODE/ESC to exit and save your edited scene into the fixtures internal 

memory. The number of steps can be defined under “EDIT” and the scenes can 

be called up under “Run.” To run the scenes see page 30. 

 

 

Editing procedure 2: Using an external controller. 

1. 

Call up the first scene in your controller now. 

2. 

Select “SC01” by pressing the UP or DOWN buttons. 

3. 

Press MODE/ESC, the display shows “SC01”. 

4. 

Press MODE/ESC, the display shows “C-01”. 

5. Select 

"CEDT" by pressing the UP or DOWN buttons. 

6. 

Press MODE/ESC, the display shows "OFF". 

7. 

Press UP, the display will read "ON". 

8. 

Press MODE/ESC, the display shows "SC02". You successfully downloaded 

the first scene. 

Summary of Contents for ELAR PAR 72 UV

Page 1: ...Rev 12 08 2010 visage Version 1 0 ELAR PAR 72 UV Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Page 2: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 1 www ElationLighting com...

Page 3: ...9 6 Mounting and Installation 12 7 Understanding DMX 15 a DMX Cables 15 b DMX Terminator 16 c 3 Pin to 5 Pin Conversion 17 d Fixture DMX Addressing 17 8 Display Indicators 19 9 Display Menu 20 10 DMX...

Page 4: ...y to operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Inside the box you should find th...

Page 5: ...nder warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the pro...

Page 6: ...pter six of this manual Operating the ELAR PAR 72 UV without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injury 5 Qualified and certified personn...

Page 7: ...tugging the wire portion of the cord 14 Please safe keeping the waterproof socket packed in the attached bag Cover the power cable and signal cable by the socket when the cable leave unused 15 Please...

Page 8: ...Field Angle 45 Lens USITT DMX 512 Complaint Preprogrammed colored macros Strobe effect with a maximum flash rate of 18fps DMX controlled operation or stand alone operation with Master Slave function...

Page 9: ...treme heat moisture or dust The minimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft See page 12 Always install the fixture with an appropriately ra...

Page 10: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 9 www ElationLighting com 5 FIXTURE OVERVIEW...

Page 11: ...in the DMX chain To maintain the integrity of the IP rating only use proper Elation IP rated DMX cables 5 MENU Button This button is used to access the fixtures menu functions 6 Up Button The up butto...

Page 12: ...connectors to maintain the IP rating 11 DMX In Lead This lead is the main DMX input lead When the unit is the first in a chain or the only fixture to be used with a DMX controller be sure to use the D...

Page 13: ...g removing or servicing the fixture Refer to regulations BGV C1 formerly VBG 70 and DIN VDE0711 217 for proper installation in Europe To ensure proper installation only qualified staff should attempt...

Page 14: ...ounting always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure See the image below Clamp Mounting The ELAR PAR 72 UV p...

Page 15: ...safety measure be sure to attach at least one properly rated safety cable to the fixture See illustrations below Securing the ELAR PAR 72 UV Always be sure to secure your fixture with a safety cable...

Page 16: ...e connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the...

Page 17: ...multiple moving heads together through serial linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out...

Page 18: ...g a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control info...

Page 19: ...whether a DMX data signal is being received or not If a DMX data signal is being received the display will show A XXX XXX representing the actual DMX address If the fixture is not receiving a DMX sign...

Page 20: ...ndicator on the display This indicator is designed to give a quick visual indication of the fixtures DMX status The illustration below details the functionality of the LED indicators The LED indicator...

Page 21: ...SLAV ON OFF Set as Slave ADDR RDMX ON OFF Change address via DMX RUN AUTO ALON MAST Run Auto program VALU D XX D 00 DXXX Display DMX value FLIP ON OFF Flip display D ON ON OFF Delay shutting off LED d...

Page 22: ...e setting for Master Slave Operation With this function you can define the device as slave for operation in Master Slave mode Each slave setting will have a different function for a dynamic lightshow...

Page 23: ...excessive light in situations that require an extremely dark environment This function will adjust the time delay the fixture will remain on before it turns off This function is disabled as default LO...

Page 24: ...manual setting that are made in the MANL menu section If this function is not activated all manual settings will be lost once the fixture is tuned off VER Software Version This function will display...

Page 25: ...total amount of steps in the built in program This setting can range between 1 and 48 steps 9 5 2 REC Auto save function 9 5 3 SCXX This function allows the user to edit the scenes in the user define...

Page 26: ...is scene needs 3 0 seconds to run Note XX is always 0 2 seconds not one second 11 Adjust the time needed by tapping the UP button 12 Press ENTER to save the settings for the scene you are editing the...

Page 27: ...com 9 Adjust the Step time as described above 10 Call up the second scene in your controller now 11 Repeat steps 5 11 until all desired scenes are downloaded 12 Press MODE ESC to exit The number of s...

Page 28: ...ile and will remain in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX addr...

Page 29: ...1 to a value of 7 set channel 2 to a value of 7 and use channel 3 to set your address to 57 by selecting a channel value of 57 Example 2 If you want to set the starting address to 420 set channel 1 to...

Page 30: ...is receiving a DMX signal Please note that this will override all manual settings This unit will keep and retain the last DMX command in the event of DMX signal failure To reset the fixture you must...

Page 31: ...o different DMX modes DMX channel functions values 2 DMX channels Channel Value Function 2CH Shutter strobe 0 31 Blackout LEDs Off 32 63 Open LEDs On 64 95 Strobe effect slow to fast 96 127 Open LEDs...

Page 32: ...ogram 1 48 then creating the scenes Keep in mind that although you can create a total of 48 unique scenes the program will only playback the total amount of steps that have been assigned to the progra...

Page 33: ...down buttons to adjust the DMX channel value 5 Press ENTER to adjust the value to any remaining channels 6 Repeat steps 3 5 until you finish setting all the DMX values for all channels of this scene...

Page 34: ...Mode and tap the Enter button In the next screen select Run and tap Enter In the next screen toggle to Auto and tap enter There are now two selections Master and Alone Select Master when running mult...

Page 35: ...over is held in place by two turn locking fasteners To remove the cover 1 Turn the locking fasteners in a counter clockwise direction 2 Once the fasteners are loose lift the cover straight up to expos...

Page 36: ...not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on the installation spot and usage have to be adhered by a skilled...

Page 37: ...with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number ha...

Page 38: ...ding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or f...

Page 39: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 38 www ElationLighting com 16 PHOTOMETRIC DATA...

Page 40: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 39 www ElationLighting com 17 DIMENSIONAL DRAWINGS...

Page 41: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 40 www ElationLighting com 18 CIRCUIT SCHEMATIC...

Page 42: ...ls DMX Drive Standard DMX 512 3 pole IP Rated Locking Connector Pin 3 Pin 2 Ground Pin 1 Color Mixing RGBW Color Additive Mixing Beam Angle 20 Beam Angle 60 Field Angle 45 Lens Dimmer Continuous Dimmi...

Page 43: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 42 www ElationLighting com...

Page 44: ...Rev 12 08 2010 visage Version 1 0 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighting com...

Reviews: