Elation ELAR EXQUADPAR HP User Instructions Download Page 3

P

ower Supply:

 The Elation ELAR EXQUADPAR HP contains a auto-

matic voltage switch, which will auto sense the voltage when it is 

plugged into the power source. With this switch there is no need to 

worry about the correct power voltage, this unit can be plugged in 

anywhere.    

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol used as a form of communication between intelligent fixtures 

and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli

-

ant. 

To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The ELAR EXQUADPAR HP can be controlled via DMX-512 protocol. 

The ELAR EXQUADPAR HP has 8 DMX Modes. The DMX address is 

set using the ELAR WR controller. Your unit and your DMX controller 

require a approved DMX-512 110 Ohm Data cable for data input and 

data output. We highly recommend the ELAR 3C-1M or ELAR 3C-5M 

DMX Cables. These cables can be used in dry, damp, or wet areas in 

indoor or outdoor enviroments. The rubber neoprene outer jacket is 

weather and ozone resistant making the cables suitable for outdoor 

use. This cable may be purchased at almost all professional sound and 

lighting stores. Remember that DMX cable must be daisy chained and 

cannot be split.

Elation Architectural  -  www.elationlighting.com  - ELAR EXQUADPAR HP - Page 5

ELAR EXQUADPAR HP                                              Set Up

Elation Architectural  -  www.elationlighting.com  - ELAR EXQUADPAR HP - Page 6

ELAR EXQUADPAR HP   

                                  Set Up

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan

-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for ELAR EXQUADPAR HP

Page 1: ...werful DMX intelligent RGBW LED par This par is light weight and compact which makes it a great piece for mobile DJ s and clubs The unit has 4 operating modes Auto Run mode Program mode RGB mode and D...

Page 2: ...upport team on our customer support number All packages returned to the service department not displaying a R A number on the outside of the package will be returned to the shipper Be sure that the lo...

Page 3: ...y damp or wet areas in indoor or outdoor enviroments The rubber neoprene outer jacket is weather and ozone resistant making the cables suitable for outdoor use This cable may be purchased at almost al...

Page 4: ...AR HP Operating Instructions Elation Architectural www elationlighting com ELAR EXQUADPAR HP Page 8 Elation Architectural www elationlighting com ELAR EXQUADPAR HP Page 7 SET ADDRESS Press this button...

Page 5: ...ion 1 COLOR MACROS Please see 1 Channel Mode 2 MASTER DIMMER 1 255 0 100 ELAR EXQUADPAR HP 3 Channel Mode Channel Value Function 1 COLOR MACROS Please see 1 Channel Mode 2 MASTER DIMMER 1 255 0 100 3...

Page 6: ...g used ELAR EXQUADPAR HP 4 Channel Mode Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1 255 0 100 4 WHITE 1 255 0 100 ELAR EXQUADPAR HP 6 Channel Mode Channel Value Function 1 RE...

Page 7: ...GE 13 208 223 COLOR CHANGE 14 224 239 COLOR CHANGE 15 240 255 COLOR CHANGE 16 COLOR FADE MODE 0 15 COLOR FADE 1 16 31 COLOR FADE 2 32 47 COLOR FADE 3 48 63 COLOR FADE 4 64 79 COLOR FADE 5 80 95 COLOR...

Page 8: ...covered by this warranty were manufactured after January 1 1990 and bear iden tifying marks to that effect E Elation Professionals reserves the right to make changes in design and or improvements upon...

Page 9: ...Elation Architectural www elationlighting com ELAR EXQUADPAR HP Page 17 Elation Architectural www elationlighting com ELAR EXQUADPAR HP Page 18 ELAR EXQUADPAR HP Notes ELAR EXQUADPAR HP Notes...

Page 10: ...730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Voltage This fixture contains a ele...

Reviews: