Elation ELAR 180 Par RGBAW Manual Download Page 10

 
 

ELAR 180 Par RGBAW

 

©Elation Professional, Los Angeles Ca. 

 

www.ElationLighting.com

   

  5. FIXTURE OVERVIEW 

 

 

 

 

 

 

Summary of Contents for ELAR 180 Par RGBAW

Page 1: ...Rev 4 26 2010 visage Version 1 1 ELAR 180PAR RGBAW Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Page 2: ...ELAR 180 Par RGBAW Elation Professional Los Angeles Ca 1 www ElationLighting com...

Page 3: ...ew 9 6 Mounting and Installation 12 7 Understanding DMX 15 a DMX Cables 15 b DMX Terminator 16 c 3 Pin to 5 Pin Conversion 17 d Fixture DMX Addressing 16 8 Display Indicators 19 9 Display Menu 20 10 D...

Page 4: ...necessary to operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Inside the box you should...

Page 5: ...er under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the...

Page 6: ...allation guide described in chapter six of this manual Operating the ELAR 180 Par RGBAW without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injur...

Page 7: ...ype of service or any cleaning procedure 13 Only handle the power cord by the plug Never pull out the plug by tugging the wire portion of the cord 14 Please be aware that damages caused by modificatio...

Page 8: ...nt Preprogrammed colored macros Strobe effect with a maximum flash rate of 25fps DMX controlled operation or stand alone operation with Master Slave function 7 built in programs can be called up via D...

Page 9: ...extreme heat moisture or dust The minimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft See page 12 Always install the fixture with an appropriately...

Page 10: ...ELAR 180 Par RGBAW Elation Professional Los Angeles Ca 9 www ElationLighting com 5 FIXTURE OVERVIEW...

Page 11: ...ure in the DMX chain To maintain the integrity of the IP rating only use proper Elation IP rated DMX cables 5 MENU Button This button is used to access the fixtures menu functions 6 Up Button The up b...

Page 12: ...r connectors to maintain the IP rating 11 DMX In Lead This lead is the main DMX input lead When the unit is the first in a chain or the only fixture to be used with a DMX controller be sure to use the...

Page 13: ...ing removing or servicing the fixture Refer to regulations BGV C1 formerly VBG 70 and DIN VDE0711 217 for proper installation in Europe To ensure proper installation only qualified staff should attemp...

Page 14: ...mounting always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure See the image below Clamp Mounting The ELAR 180 Par R...

Page 15: ...safety measure be sure to attach at least one properly rated safety cable to the fixture See illustrations below Securing the ELAR 180 Par RGBAW Always be sure to secure your fixture with a safety ca...

Page 16: ...in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The...

Page 17: ...bles provided through Elation Always be sure to daisy chain your in and out data connections never split or Y your DMX connections unless you are using an approved DMX splitter such as the Elation Opt...

Page 18: ...e digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of...

Page 19: ...is not receiving a DMX signal the display will flash A XXX XXX representing the actual DMX address If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX sig...

Page 20: ...ED indicator on the display This indicator is designed to give a quick visual indication of the fixtures DMX status The illustration below details the functionality of the LED indicators The LED indic...

Page 21: ...lt setting DIMR MOD1 MODE2 Set dimmer mode POHO ON OFF Power on to preserve the MANL data SET VER V 1 0 V 9 9 Software version MANL RED GREN BLUE WHIT AMBE TEMP MACO PROG STRB DIMM R XXX 000 255 G XXX...

Page 22: ...on coming from the controller that is not meant specifically for the fixture Because each fixture is connected in a daisy chain fashion it is imperative to assign a proper and unique starting DMX addr...

Page 23: ...dit the individual scenes under Edit scenes With this function you can run the individual scenes either automatically i e with the adjusted Step Time 9 1 3 DISP Menu Display Settings This function all...

Page 24: ...ure Personality Settings These functions set specific running modes and operating parameters CHAN DMX Mode settings This function allows the fixture to run in different DMX channel modes Four modes ar...

Page 25: ...ten DMX channels to be controlled manually This will allow the fixture to be preset to a specific color or built in program without the use of a DMX console 9 4 TIME Operating Hours These functions w...

Page 26: ...or detailed instructions on how to complete this task please see Working with Built In Programs Section 12 Page 35 9 5 1 Select program This function allows the user to select one of ten of the user d...

Page 27: ...atile and will remain in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX ad...

Page 28: ...255 When set to 8 you can adjust the starting address between 256 and 511 3 Use channel 3 to set your desired DMX starting address For example If you want to set the starting address to 57 set channel...

Page 29: ...eding pages outlines the different DMX traits for the four different DMX modes DMX channel functions and values Mode Channel Value Function 5CH 6CH 8CH 10CH Red LED 1 1 1 1 0 255 Red 0 Black 255 100 R...

Page 30: ...168 175 Color Macro 22 176 183 Color Macro 23 184 191 Color Macro 24 192 199 Color Macro 25 200 207 Color Macro 26 208 215 Color Macro 27 216 223 Color Macro 28 224 231 Color Macro 29 232 239 Color M...

Page 31: ...m 128 159 Pulse effect in sequences 160 191 LEDs on 192 223 Random strobe effect slow to fast 224 255 LEDs on General dimming speed 0 255 Dimming 0 Black 255 100 Speed from slow to fast when running i...

Page 32: ...one or a maximum of 64 scenes Keep in mind that a scene can only be access when it is stored in a Program If you wish to build a static scene a scene consisting of no movement for a logo or gobo proj...

Page 33: ...rder allows you to build a scene using your own DMX console That scene can then be sent to the fixture and be stored inside one of the fixture s scene storage banks Many people may find this procedure...

Page 34: ...e Program Edit menu function Step 3 Playing a Program To initiate a program follow the procedure below Access the main menu and use the Up and Down to toggle to Function Mode and tap the Enter button...

Page 35: ...ns cover is held in place by two turn locking fasteners To remove the cover 1 Turn the locking fasteners in a counter clockwise direction 2 Once the fasteners are loose lift the cover straight up to e...

Page 36: ...st not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on the installation spot and usage have to be adhered by a skille...

Page 37: ...d with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number...

Page 38: ...luding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or...

Page 39: ...ELAR 180 Par RGBAW Elation Professional Los Angeles Ca 38 www ElationLighting com 16 PHOTOMETRIC DATA...

Page 40: ...ELAR 180 Par RGBAW Elation Professional Los Angeles Ca 39 www ElationLighting com 17 DIMENSIONAL DRAWINGS...

Page 41: ...ELAR 180 Par RGBAW Elation Professional Los Angeles Ca 40 www ElationLighting com 18 CIRCUIT SCHEMATIC...

Page 42: ...d Pin 1 Color Mixing RGBW Color Additive Mixing Beam Angle 9 Beam Angle Standard 15 Lens Field Angle 22 Standard 15 Lens Luminance 10 930 Lux 1 015 FC at 8 2 5m Fuse GMA 220v 2A Internal Dimmer Contin...

Page 43: ...ELAR 180 Par RGBAW Elation Professional Los Angeles Ca 42 www ElationLighting com...

Page 44: ...Rev 4 26 2010 visage Version 1 1 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...

Reviews: