MODE OF OPERATION 

The mode of operation described in the following chapter is based on a standard ELATEC RFID reader module equipped with two 
LEDs. Depending on your product (number of LEDs, installed firmware, etc.) and in case the product settings have been modified with 
the AppBlaster tool, the information below might differ from your product configuration when in operation. In particular, the color and 
sequence of the LEDs on your product might be different. 
 

5.1

 

OPERATING MODE 

 
In order to start operating TWN4 Palon Compact LEGIC M, it simply has to be connected directly to a host device. 
 

5.2

 

POWER UP 

 
In case of an external power supply unit is used, the following requirements must be satisfied: 

 

Limited power source according to the safety standards listed in the respective declaration(s) of conformity 

 

Short-circuit current < 8 A 

 
Once TWN4 Palon Compact LEGIC M is connected to the host device, it detects the type of communications cable (e.g. USB or RS-

232), with which it is connected to the host. 

In case of RS-232: Additionally, the RS-232 is sending a version string via RS-232 to the host device. 

 

5.3

 

ENUMERATION 

 
This is only applicable for the USB version: Once the device has been powered up, it is waiting for completion of the enumeration by 
the USB host. As long as the device is not enumerated, it is entering a minimum power consumption mode, where both LEDs are 
turned off. 
 

5.4

 

INITIALIZATION 

 
After powering up and enumeration (in USB mode), the device is turning on the built-in transponder reader logic. The green LED is 
turned on permanently. Some RFID reader modules need some kind of initialization, which is performed in this step. After successful 
initialization, the device sounds a short sequence, which consists of a lower tone followed by a higher tone. 
 

5.5

 

NORMAL OPERATION 

 
As soon as the reader module has completed the initialization, it is entering normal operation. During normal operation, the reader 
module is searching for a transponder continuously. 
 

5.6

 

DETECTION OF A TRANSPONDER 

 
If a transponder is detected by the reader module, following actions are performed: 

 

Send the ID to the host. By default, the USB device sends by emulating keystrokes of a keyboard. An RS-232 device sends the 

ASCII code of an ID. 

 

Sound a beep. 

 

Turn off the green LED. 

 

Blink the red LED for two seconds. 

 

Turn on the green LED. 

 

Summary of Contents for TWN4 PALON COMPACT LEGIC M

Page 1: ...TWN4 PALON COMPACT LEGIC M USER MANUAL ...

Page 2: ...ODE OF OPERATION 8 5 1 OPERATING MODE 8 5 2 POWER UP 8 5 3 ENUMERATION 8 5 4 INITIALIZATION 8 5 5 NORMAL OPERATION 8 5 6 DETECTION OF A TRANSPONDER 8 5 7 SUSPEND MODE 9 6 COMPLIANCE STATEMENTS 10 6 1 EU 10 6 2 FCC 10 6 3 IC 10 6 4 RF EXPOSURE COMPLIANCE 11 6 5 UNITED KINGDOM 11 6 6 FURTHER STATEMENTS 11 6 6 1 BRAZIL 11 6 6 2 MEXICO 11 6 6 3 TAIWAN ROC 11 6 6 4 THAILAND 12 APPENDIX 13 A TERMS AND A...

Page 3: ...iscrepancy the original version in English will prevail 1 2 SCOPE OF DELIVERY 1 2 1 COMPONENTS AND ACCESSORIES Depending on your product configuration the product can be delivered alone or with different components and accessories such as cables or wall holders as part of a kit For more information about the delivered components and accessories refer to your delivery note consult the ELATEC websit...

Page 4: ...erits all advantages and integrated tool support of the ELATEC TWN4 family Although it is a general purpose device it is optimized for time attendance and access control The product is intended to be integrated into a host device Any use other than the intended use described in this section as well as any failure to comply with the safety information given in this document is considered improper u...

Page 5: ...mended by ELATEC ELATEC excludes any liability for damages or injuries resulting from the use of spare parts or accessories other than the ones sold or recommended by ELATEC Like most electronic devices RFID systems generate electromagnetic waves that can vary in amplitude and frequency It is generally known and accepted that some RFID devices might potentially interfere with personal medical devi...

Page 6: ...6 of 14 If you are unsure about any part of the safety information above contact ELATEC support Any failure to comply with the safety information given in this document is considered improper use ELATEC excludes any liability in case of improper use or faulty product installation ...

Page 7: ...Peak typ 250 mA 12 V Antennas The reader module is equipped with the following antennas TWN4 Palon Compact LEGIC M HF antenna 13 56 MHz Dimensions 39 x 42 5 mm 1 54 x 1 67 inch Number of turns 3 LF antenna 125 kHz Dimensions 27 x 27 5 mm 1 06 x 1 08 inch Number of turns 179 BLE 2 4 GHz The antenna for the BLE module is integrated in the BLE chip For more information refer to the related product da...

Page 8: ...S 232 Additionally the RS 232 is sending a version string via RS 232 to the host device 5 3 ENUMERATION This is only applicable for the USB version Once the device has been powered up it is waiting for completion of the enumeration by the USB host As long as the device is not enumerated it is entering a minimum power consumption mode where both LEDs are turned off 5 4 INITIALIZATION After powering...

Page 9: ...the red LED a different transponder is detected the complete sequence restarts immediately 5 7 SUSPEND MODE The USB version of the reader module supports the USB suspend mode If the USB host is signaling suspend via the USB bus the reader module is turning off most of its power consuming peripherals During this operation mode no detection of transponders is possible and all LEDs are turned off Onc...

Page 10: ...l interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re...

Page 11: ...ompany s name and a contact address in the United Kingdom UKCA marking 6 6 FURTHER STATEMENTS Should the device be certified and installed in the following countries or regions the corresponding statements see below must be contained in the user manual 6 6 1 BRAZIL Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente a...

Page 12: ... 2022 ELATEC GmbH TWN4 Palon Compact LEGIC M user manual DocRev2 02 2022 Page 12 of 14 6 6 4 THAILAND ...

Page 13: ... low frequency NFC near field communication PCB printed circuit board RFID radio frequency identification UKCA UK conformity assessed WEEE Waste of electrical and electronic equipment Refers to Directive 2012 19 EU of the European Parliament and of the Council of the European Union B RELEVANT DOCUMENTATION ELATEC documentation ELATEC quick start guide TWN4 Palon Compact LEGIC M data sheet TWN4 Pal...

Page 14: ...cation has to be validated by the customer himself at his own responsibility Where application information is given it is only advisory and does not form part of the specification Disclaimer All names used in this document are registered trademarks of their respective owners 2022 ELATEC GmbH TWN4 Palon Compact LEGIC M user manual DocRev2 02 2022 ELATEC GMBH Zeppelinstr 1 82178 Puchheim Germany P 4...

Reviews: