background image

 

  

 

TWN4 MULTITECH LEGIC M 

 

 

USER MANUAL 

Summary of Contents for TWN4 MULTITECH LEGIC M

Page 1: ...TWN4 MULTITECH LEGIC M USER MANUAL ...

Page 2: ...ERATION 8 5 1 OPERATING MODE 8 5 2 POWER UP 8 5 3 ENUMERATION 8 5 4 INITIALIZATION 8 5 5 NORMAL OPERATION 8 5 6 DETECTION OF A TRANSPONDER 8 5 7 SUSPEND MODE 9 6 COMPLIANCE STATEMENTS 10 6 1 EU 10 6 2 FCC 10 6 3 IC 10 6 4 RF EXPOSURE COMPLIANCE 10 6 5 CHINA PRC 11 6 6 UNITED KINGDOM 12 6 7 FURTHER STATEMENTS 12 6 7 1 BRAZIL 12 6 7 2 MEXICO 12 6 7 3 TAIWAN ROC 13 6 7 4 THAILAND 13 APPENDIX 14 A TER...

Page 3: ...1 COMPONENTS AND ACCESSORIES Depending on your product configuration the product can be delivered alone or with different components and accessories such as cables or wall holders as part of a kit For more information about the delivered components and accessories refer to your delivery note consult the ELATEC website or contact ELATEC 1 2 2 SOFTWARE The product is delivered ex works with a specif...

Page 4: ...ices are available which cover a large range of transponder types both in the frequency range of 125 kHz and 13 56 MHz The product is intended to be integrated into a host device Any use other than the intended use described in this section as well as any failure to comply with the safety information given in this document is considered improper use ELATEC excludes any liability in case of imprope...

Page 5: ...ecommended by ELATEC ELATEC excludes any liability for damages or injuries resulting from the use of spare parts or accessories other than the ones sold or recommended by ELATEC Like most electronic devices RFID systems generate electromagnetic waves that can vary in amplitude and frequency It is generally known and accepted that some RFID devices might potentially interfere with personal medical ...

Page 6: ...of 15 If you are unsure about any part of the safety information above contact ELATEC support Any failure to comply with the safety information given in this document is considered improper use ELATEC excludes any liability in case of improper use or faulty product installation ...

Page 7: ...r CNB 3 3 V 5 Current consumption RF field on 140 mA typically Antennas The reader module is equipped with the following antennas TWN4 MultiTech LEGIC M HF antenna 13 56 MHz Dimensions 44 x 46 mm 1 73 x 1 81 inch Number of turns 3 LF antenna 125 kHz Dimensions 29 x 32 mm 1 14 x 1 26 inch Number of turns 164 For more information refer to the related product data sheet or other technical documents ...

Page 8: ...or completion of the enumeration by the USB host As long as the device is not enumerated it is entering a minimum power consumption mode where both LEDs are turned off 5 4 INITIALIZATION After powering up and enumeration the device is turning on the built in transponder reader logic The green LED is turned on permanently Some readers need some kind of initialization which is performed in this step...

Page 9: ... host is signaling suspend via the USB bus the reader module is turning off most of its power consuming peripherals During this operation mode no detection of transponders is possible and all LEDs are turned off Once the host is resuming to normal operation mode this is also signaled via the USB bus Therefore the reader module will resume to normal operation too ...

Page 10: ...lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit...

Page 11: ... are not allowed 3 The product may not interfere in any way with any legal radio transmitters stations and may not offer any shielding from harmful interference 4 The product must be able to tolerate interference caused by industrial scientific and medical ISM devices which radiate high frequency energy or other legal interference from radio transmitters stations 5 Should the product cause harmful...

Page 12: ...t TWN4 MultiTech LEGIC M 的工作电压 4 3V 5 5V USB 供电 工作温度 25 80 储存温度 40 85 用户需严格按照此温度和电压要求使用 6 6 UNITED KINGDOM TWN4 MultiTech LEGIC M complies with the requirements of the UK legislations and other regulations as listed in the respective UK declaration of conformity The importer is responsible for applying the following information to the packaging of the product the importer company s details includi...

Page 13: ...anual DocRev3 02 2022 Page 13 of 15 6 7 3 TAIWAN ROC 注意 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更頻率 加大功率或變更原設計之特性及 功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應立即停用 並改善至無干擾時 方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合法通信或工業 科學及 醫療用電波輻射性電機設備之干擾 6 7 4 THAILAND ...

Page 14: ... LF low frequency PCB printed circuit board RFID radio frequency identification UKCA UK conformity assessed WEEE Waste of electrical and electronic equipment Refers to Directive 2012 19 EU of the European Parliament and of the Council of the European Union B RELEVANT DOCUMENTATION ELATEC documentation ELATEC quick start guide TWN4 MultiTech LEGIC M data sheet TWN4 MultiTech LEGIC M integration man...

Page 15: ...lication has to be validated by the customer himself at his own responsibility Where application information is given it is only advisory and does not form part of the specification Disclaimer All names used in this document are registered trademarks of their respective owners 2022 ELATEC GmbH TWN4 MultiTech LEGIC M user manual DocRev3 02 2022 ELATEC GMBH Zeppelinstr 1 82178 Puchheim Germany P 49 ...

Reviews: